ANUNCIAR
PSI-REP-DNET CAN 2313423 PHOENIX CONTACT Repeater View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

PSI-REP-DNET CAN 2313423 PHOENIX CONTACT Repeater

PSI-REP-DNET CAN

2313423

PHOENIX_CONTACT

Repeater

Modular repeater for galvanic separation and range increase for DeviceNet™, SDS/CANopen®, transmission speed up to 1 MBit/s. High-quality galvanic separation between interfaces, for rail mounting, 24 V DC power supply

Modular repeater for electrical isolation and increasing the range for DeviceNet™, SDS, CANopen®, data rate of up to 1 Mbps, high-quality electrical isolation between the interfaces, DIN-rail mountable, 24 V DC supply

More details


PLC's > PLC communication module

Safety

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total: $749.32
Unit price: $749.32
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Best sellers

More info



Technical data

Notes
Note on application
Note on applicationOnly for industrial use
Utilization restriction
CCCex noteUse in potentially explosive areas is not permitted in China.

Product properties
Product typeInterface converter
MTTF1091 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
514 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%)
208 Years (SN 29500 standard, temperature 40°C, operating cycle 100%)
MTBF823 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day))
170 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day))
Data management status
Article revision09

Electrical properties
Electrical isolationVCC // TBUS // CAN A // CAN B
Maximum power dissipation for nominal condition1.32 W
Test voltage data interface/power supply1.5 kVrms(50 Hz, 1 min.)
Rated insulation voltage85 V DC (In accordance with EN/IEC 60079-7, Annex H)
Supply
Supply voltage range10 V DC ... 30 V DC (via pluggable COMBICON screw terminal block)
Nominal supply voltage24 V DC
Typical current consumption55 mA (24 V DC)
Max. current consumption80 mA
≤ 2 A (For operation in a joining station, via the DIN rail connector)
Function
Status and diagnostic indicatorsLEDs: VCC (supply voltage), NET A (Mod/Net status port A), NET B (Mod/Net status port B), ACT (activity/data traffic)

Output data
Switching
Output nameRelay output
Number of outputs1
Contact switching typeN/C contact
Minimum switching voltage10 V DC
Maximum switching voltage30 V DC
Limiting continuous current500 mA

Connection data
Supply
Stripping length7.00 mm
Tightening torque0.56 Nm ... 0.79 Nm

Interfaces
Bit distortion, input± 35 %
Bit distortion, output< 6.25 %
Bit delayOne telegram length (EXTENDED)
SignalCAN
CANopen®
DeviceNet™
Data: CAN interface, in accordance with ISO/IS 11898 for DeviceNet™, CAN, CANopen®
Transmission speed≤ 1 Mbps (Configurable via DIP switches)
Connection methodCOMBICON plug-in screw terminal block
No. of channels2 (CAN_High / CAN_Low)
Transmission length≤ 5000 m (Dependent on the data rate and the protocol used)
Number of bus devices≤ 64 (per potential segment)
≤ 63 (DeviceNet™, can be addressed logically)
≤ 128 (CANopen®, can be addressed logically)
Termination resistor124 Ω (Integrated and ready to be switched)
Single conductor/terminal point, rigid0.2 mm² ... 2.5 mm²
Single-wire/terminal point, flexible0.2 mm² ... 2.5 mm²
Max. AWG conductor cross section, flexible14
Min. AWG conductor cross section, flexible24
Single-wire/terminal point, rigid AWG max.14
Single-wire/terminal point, rigid AWG min.24
Stripping length7 mm
Transmission medium2-wire twisted pair, shielded
Transmission methodCSMA/CA
File format/codingBit stuffing, NRZ
Data: CAN interface, in accordance with ISO/IS 11898 for DeviceNet™, CAN, CANopen®
Transmission speed≤ 1 Mbps (Configurable via DIP switches)
Connection methodCOMBICON plug-in screw terminal block
No. of channels2 (CAN_High / CAN_Low)
Transmission length≤ 5000 m (Dependent on the data rate and the protocol used)
Number of bus devices≤ 64 (per potential segment)
≤ 63 (DeviceNet™, can be addressed logically)
≤ 128 (CANopen®, can be addressed logically)
Termination resistor124 Ω (Integrated and ready to be switched)
Single conductor/terminal point, rigid0.2 mm² ... 2.5 mm²
Single-wire/terminal point, flexible0.2 mm² ... 2.5 mm²
Max. AWG conductor cross section, flexible14
Min. AWG conductor cross section, flexible24
Single-wire/terminal point, rigid AWG max.14
Single-wire/terminal point, rigid AWG min.24
Transmission medium2-wire twisted pair, shielded
Transmission methodCSMA/CA
File format/codingBit stuffing, NRZ

Dimensions
Dimensional drawingehyqtpocwt.jpg
Width35 mm
Height111 mm
Depth121 mm

Material specifications
Color (Housing)green (RAL 6021)
Material (Housing)PA 6.6-FR

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP20
Ambient temperature (operation)-20 °C ... 60 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Altitude≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation)
Permissible humidity (operation)30 % ... 95 % (non-condensing)

Approvals
CE
CertificateCE-compliant
ATEX
Identification II 3 G Ex ec IIC T4 Gc
CertificatePxCIF07ATEX2313533X
NotePlease follow the special installation instructions in the documentation!
UKEX
Identification II 3 G Ex ec IIC T4 Gc
CertificatePxCIMA22UKEX2313423X
UL, USA/Canada
Identification508 Listed
Corrosive gas test
IdentificationISA-S71.04-1985 G3 Harsh Group A
Shipbuilding
IdentificationDNV GL
DNV GL data
TemperatureB
HumidityA
VibrationA
EMCB
EnclosureRequired protection according to the Rules shall be provided upon installation on board

EMC data
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Noise immunityEN 61000-6-2
Noise emissionEN 55011
Electrostatic discharge
Standards/regulationsEN 61000-4-2
Electrostatic discharge
Contact discharge± 6 kV
Discharge in air± 8 kV
CommentsCriterion B
Electromagnetic HF field
Standards/regulationsEN 61000-4-3
Electromagnetic HF field
Frequency range80 MHz ... 3 GHz
Field intensity10 V/m
CommentsCriterion A
Fast transients (burst)
Standards/regulationsEN 61000-4-4
Fast transients (burst)
Input± 2 kV
Signal± 2 kV
CommentsCriterion B
Surge current load (surge)
Standards/regulationsEN 61000-4-5
Surge current load (surge)
Input± 0.5 kV
Signal± 1 kV
CommentsCriterion B
Conducted interference
Standards/regulationsEN 61000-4-6
Conducted interference
CommentsCriterion A
Voltage10 V
Emitted interference
Standards/regulationsEN 55011
CommentsClass A, industrial applications
Criteria
Criterion ANormal operating behavior within the specified limits.
Criterion BTemporary impairment to operational behavior that is corrected by the device itself.

Standards and regulations
Free from substances that could impair the application of coatingVDMA 24364:2018-05

Mounting
Mounting typeDIN rail mounting
Assembly noteThe product can be snapped onto all 35 mm DIN rails in accordance with EN 60715.

ETIM for 2313423 PLC's (EC001423)
Feature Name Feature Value
Number of HW-interfaces industrial Ethernet (EF003020) 0
Number of interfaces PROFINET (EF006932) 0
Number of HW-interfaces RS-232 (EF003021) 0
Number of HW-interfaces RS-422 (EF003022) 0
Number of HW-interfaces RS-485 (EF003023) 0
Number of HW-interfaces serial TTY (EF003024) 0
Number of HW-interfaces USB (EF003025) 0
Number of HW-interfaces parallel (EF003026) 0
Number of HW-interfaces wireless (EF006933) 0
Number of HW-interfaces other (EF003027) 0
With optical interface (EF003028) No
Radio standard Bluetooth (EF007178) No
Radio standard WLAN 802.11 (EF007179) No
Radio standard GPRS (EF008523) No
Radio standard GSM (EF008524) No
Radio standard UMTS (EF008525) No
IO link master (EF007298) No
Redundancy (EF003156) No
With potential separation (EF003272) No
SIL according to IEC 61508 (EF009889) None
Suitable for safety functions (EF001597) No
Performance level according to EN ISO 13849-1 (EF007399) None
Appendant operation agent (Ex ia) (EF004141) No
Appendant operation agent (Ex ib) (EF004142) No
Explosion safety category for gas (EF003997) None
Explosion safety category for dust (EF003998) None
Width (EF000008) 35 mm
Height (EF000040) 111 mm
Depth (EF000049) 121 mm

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.