MCR potentiometer position converter for conversion of potentiometer positions into an analog normalized signal, 0 input Ω ... 100 Ω at 0 kΩ ... 100 kΩ

More details


Sensors > Isolation amplifier

INTERFACE Components (IF)

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total: $357.79
Unit price: $357.79
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Often bought together

Best sellers

More info



Key Commercial Data

Orderkey2864095
Packing unit1 pc
Catalog pagePage 111 (C-7-2015)
GTIN4046356046442
Weight per Piece (excluding packing)73.170 g
Custom tariff number85437090
Country of originDE (Germany)

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Dimensions

Width6.2 mm
Height93.1 mm
Depth102.5 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 65 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C

Input data

Potentiometer100 Ω ... 100 kΩ
Reference voltage source< 3.6 V

Output data

Voltage output signal0 V ... 5 V
0 V ... 10 V
1 V ... 5 V
10 V ... 0 V
Current output signal0 mA ... 20 mA
4 mA ... 20 mA
20 mA ... 0 mA
20 mA ... 4 mA
Max. voltage output signal12.5 V
Max. current output signal23 mA
Load/output load voltage output> 10 kΩ
Load/output load current output< 500 Ω (20 mA)

Power supply

Supply voltage24 V DC
19.2 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
Current consumption< 25 mA (at 24 V DC)

Connection data

Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section AWG min.26
Conductor cross section AWG max.12
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Stripping length12 mm
Screw threadM3
Connection methodScrew connection

General

Maximum transmission error< 0.2 %
Maximum temperature coefficient< 0.02 %/K
Temperature coefficient, typical< 0.02 %/K
Ambient temperature (operation)-20 °C ... 65 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Housing materialPBT
Colorgreen
ConformanceCE-compliant
ATEX II 3 G Ex nA IIC T4 Gc X
UL, USA/CanadaUL 508 Recognized

EMC data

DesignationElectromagnetic RF field
Standards/regulationsEN 61000-4-3
Typical deviation from the measuring range final value5 %
DesignationFast transients (burst)
Standards/regulationsEN 61000-4-4
Typical deviation from the measuring range final value5 %
DesignationConducted interferences
Standards/regulationsEN 61000-4-6
Typical deviation from the measuring range final value5 %

Standards and Regulations

Electromagnetic compatibilityConformance with EMC directive
Noise emissionEN 61000-6-4
Connection in acc. with standardCUL
DesignationElectromagnetic RF field
Standards/regulationsEN 61000-4-3
EN 61000-4-4
DesignationConducted interferences
Standards/regulationsEN 61000-4-6
Electrical isolationBasic insulation according to EN 61010
ConformanceCE-compliant
ATEX II 3 G Ex nA IIC T4 Gc X
UL, USA/CanadaUL 508 Recognized
Class I, Div. 2, Groups A, B, C, D T4
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 2

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications


ETIM for 2864095 Sensors (EC002653)
Feature Name Feature Value
Type of power supply (EF001469) Other
Rated supply voltage DC (EF007078) 19.2 V
Number of input ranges -60 mV ... +60 mV (EF006927) 0
Number of input ranges -100 mV ... +100 mV (EF006912) 0
Number of input ranges -300 mV ... +300 mV (EF006920) 0
Number of input ranges -500 mV ... +500 mV (EF006926) 0
Number of input ranges -1 V ... +1 V (EF006906) 0
Number of input ranges -2 V ... +2 V (EF006913) 0
Number of input ranges -2.5 V ... +2.5 V (EF006915) 0
Number of input ranges -5 V ... +5 V (EF006923) 0
Number of input ranges -10 V ... +10 V (EF006909) 0
Number of input ranges -20 V ... +20 V (EF006917) 0
Number of input ranges 0 mV ... 60 mV (EF006905) 0
Number of input ranges 0 mV ... 100 mV (EF006893) 0
Number of input ranges 0 mV ... 200 mV (EF006898) 0
Number of input ranges 0 mV ... 300 mV (EF006901) 0
Number of input ranges 0 mV ... 500 mV (EF006904) 0
Number of input ranges 0 V ... 1 V (EF006890) 0
Number of input ranges 0 V ... 2 V (EF006894) 0
Number of input ranges 0 V ... 2.5 V (EF006895) 0
Number of input ranges 0 V ... 5 V (EF006903) 0
Number of input ranges 0 V ... 10 V (EF006892) 0
Number of input ranges 0 V ... 20 V (EF006897) 0
Number of input ranges 0 V ... 24 V (EF006899) 0
Number of input ranges 0 V ... 30 V (EF006900) 0
Number of input ranges 1 V ... 5 V (EF006907) 0
Number of input ranges 2 V ... 10 V (EF006914) 0
Number of input ranges +5 V ... -5 V (EF006889) 0
Number of input ranges +10 V ... -10 V (EF006888) 0
Number of input ranges 5 V ... 0 V (EF006924) 0
Number of input ranges 5 V ... 1 V (EF006925) 0
Number of input ranges 10 V ... 0 V (EF006910) 0
Number of input ranges 10 V ... 2 V (EF006911) 0
Number of input ranges 0 mA ... 5 mA (EF006902) 0
Number of input ranges 0 mA ... 10 mA (EF006891) 0
Number of input ranges 0 mA ... 20 mA (EF006896) 0
Number of input ranges 4 mA ... 20 mA (EF006921) 0
Number of input ranges -5 mA ... +5 mA (EF006922) 0
Number of input ranges -10 mA ... +10 mA (EF006908) 0
Number of input ranges -20 mA ... +20 mA (EF006916) 0
Number of input ranges 20 mA ... 0 mA (EF006918) 0
Number of input ranges 20 mA ... 4 mA (EF006919) 0
Number of output ranges -60 mV ... +60 mV (EF006880) 0
Number of output ranges -100 mV ... +100 mV (EF006865) 0
Number of output ranges -300 mV ... +300 mV (EF006873) 0
Number of output ranges -500 mV ... +500 mV (EF006879) 0
Number of output ranges -1 V ... +1 V (EF006859) 0
Number of output ranges -2 V ... +2 V (EF006866) 0
Number of output ranges -2.5 V ... +2.5 V (EF006868) 0
Number of output ranges -5 V ... +5 V (EF006876) 0
Number of output ranges -10 V ... +10 V (EF006862) 0
Number of output ranges -20 V ... +20 V (EF006870) 0
Number of output ranges 0 mV ... 60 mV (EF006858) 0
Number of output ranges 0 mV ... 100 mV (EF006846) 0
Number of output ranges 0 mV ... 200 mV (EF006851) 0
Number of output ranges 0 mV ... 300 mV (EF006854) 0
Number of output ranges 0 mV ... 500 mV (EF006857) 0
Number of output ranges 0 V ... 1 V (EF006843) 0
Number of output ranges 0 V ... 2 V (EF006847) 0
Number of output ranges 0 V ... 2.5 V (EF006848) 0
Number of output ranges 0 V ... 5 V (EF006856) 1
Number of output ranges 0 V ... 10 V (EF006845) 1
Number of output ranges 0 V ... 20 V (EF006850) 0
Number of output ranges 0 V ... 24 V (EF006852) 0
Number of output ranges 0 V ... 30 V (EF006853) 0
Number of output ranges 1 V ... 5 V (EF006860) 1
Number of output ranges 2 V ... 10 V (EF006867) 0
Number of output ranges +5 V ... -5 V (EF006842) 0
Number of output ranges +10 V ... -10 V (EF006841) 0
Number of output ranges 5 V ... 0 V (EF006877) 0
Number of output ranges 5 V ... 1 V (EF006878) 0
Number of output ranges 10 V ... 0 V (EF006863) 1
Number of output ranges 10 V ... 2 V (EF006864) 0
Number of output ranges 0 mA ... 5 mA (EF006855) 0
Number of output ranges 0 mA ... 10 mA (EF006844) 0
Number of output ranges 0 mA ... 20 mA (EF006849) 1
Number of output ranges 4 mA ... 20 mA (EF006874) 1
Number of output ranges -5 mA ... +5 mA (EF006875) 0
Number of output ranges -10 mA ... +10 mA (EF006861) 0
Number of output ranges -20 mA ... +20 mA (EF006869) 0
Number of output ranges 20 mA ... 0 mA (EF006871) 1
Number of output ranges 20 mA ... 4 mA (EF006872) 1
Number of channels (EF000259) 1
Malfunction message output (EF007499) No
Inherently safe according to EN 60947-5-6 NAMUR (EF007112) No
SIL according to IEC 61508 (EF009889) None
Height (EF000040) 93.1 mm
Width (EF000008) 6.2 mm
Depth (EF000049) 101.2 mm
Power consumption (EF000346) 0.5 W
Load (EF007096) 500 Ohm
Operating temperature (EF002393) -20 °C
Temperature drift (EF007507) 0.02 %/K
Construction type of device (EF007276) Built-in device
Type of electric connection (EF003961) Screw connection
Mounting method (EF000003) Snap mounting support rail
Degree of protection (IP) (EF005474) IP20

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.