CTM 2X1-180DC-GS-P 2838623 PHOENIX CONTACT LSA-PLUS protective plug (COMTRAB CTM) with power cross and coars.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

CTM 2X1-180DC-GS-P 2838623 PHOENIX CONTACT LSA-PLUS protective plug (COMTRAB CTM) with power cross and coars..

CTM 2X1-180DC-GS-P

2838623

PHOENIX_CONTACT

10

Available

Ship on today

LSA-PLUS protective plug (COMTRAB CTM) with power cross and coarse surge protection for 2 signal lines. Nominal voltage: 180 V DC

More details


Overvoltage Protection Over Voltage

TRABTECH Power and Signal Quality - PHOENIX CONTACT

Surge protection for information technology - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
10+16,88 €
20+16,45 €
30+16,24 €
40+16,11 €
50+16,07 €
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Dimensions

Height21 mm
Width9.5 mm
Depth53.5 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 85 °C
Degree of protectionIP20

General

Housing materialPA
Flammability rating according to UL 94V0
Colorblack
Standards for cearances and creepage distancesDIN VDE 0110-1
IEC 60664-1
Overvoltage categoryII
Pollution degree2
Mounting typeOn CT-TERMIBLOCK and LSA-PLUS disconnect strip
TypeLSA-PLUS module
Direction of actionLine-Line & Line-Earth Ground
Arrester can be tested with CHECKMASTER from software version:From SW rev. 2.20
Near-end crosstalk attenuation aN between adjacent articles70 dB (up to 1 MHz 100 Ω system)
50 dB (up to 10 MHz 100 Ω system)
30 dB (up to 100 MHz, 100 Ω system)

Protective circuit

IEC test classificationA2
B1
B2
B3
C1
C2
C3
D1
D2
VDE requirement classA2
B1
B2
B3
C1
C2
C3
D1
D2
Nominal voltage UN180 V DC
Maximum continuous voltage UC± 180 V DC
Maximum continuous voltage UC (wire-ground)± 180 V DC
Nominal current IN120 mA (25 °C)
Operating effective current IC at UC≤ 2 µA
Residual current IPE≤ 2 µA
Nominal discharge current In (8/20) µs (Core-Earth)5 kA
Total surge current (8/20) µs10 kA
Total surge current (10/350) µs2.5 kA
Max. discharge current Imax (8/20) µs maximum (Core-Earth)10 kA (in total)
Nominal pulse current Ian (10/1000) µs (Core-Earth)200 A
Impulse discharge current (10/350)˽µs, peak value limp1 kA
Output voltage limitation at 1 kV/µs (Core-Earth) spike≤ 800 V
Output voltage limitation at 1 kV/µs (Core-Earth) static≤ 800 V
Residual voltage at In (conductor-ground)≤ 70 V
Residual voltage with Ian (10/1000)µs (conductor-ground)≤ 28 V
Voltage protection level Up (core-ground)≤ 900 V (C2 - 10 kV/5 kA, spike)
≤ 70 V (C2 - 10 kV/5 kA, static)
≤ 1 kV (C3, 7.5 kV/100 A, spike)
≤ 30 V (C3, 7.5 kV/100 A, static)
Response time tA (Core-Earth)≤ 100 ns
Input attenuation aE, asym.0.5 dB (≤ 10 MHz)
0.6 dB (up to 60 MHz in 100 Ω system)
1 dB (up to 100 MHz, 100 Ω)
Cut-off frequency fg (3 dB), asym. (PE) in 100 Ohm system> 100 MHz
Capacity (Core-Earth)5 pF (f=1 MHz / VR= 0 V)
Resistance in series5.5 Ω ±1.5 Ω (symmetry: +/- 0.5 Ω)
5.5 Ω (+/- 1.5 Ω)
Impulse durability (conductor-ground)C2 - 4 kV/2 kA
C3 - 100 A
B2 - 4 kV/100 A
D1 - 1 kA
Alternating current carrying capacity (conductor-ground)5 A - 1 s

Connection data

Connection methodcan be plugged into COMTRAB-TERMIBLOCK and LSA-PLUS disconnect and switching strips
Connection type INCOMTRAB plug-in system
Connection type OUTCOMTRAB plug-in system
Connection methodLSA-PLUS

Connection, equipotential bonding

Connection methodSpring contact

Standards and Regulations

Standards/regulationsIEC 61643-21