FLM TEMP 4 RTD M12 2736819 PHOENIX CONTACT The local bus device has 4 inputs for resistive temperature senso.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

FLM TEMP 4 RTD M12 2736819 PHOENIX CONTACT The local bus device has 4 inputs for resistive temperature senso..

FLM TEMP 4 RTD M12

2736819

PHOENIX_CONTACT

Available

Ship on today

The local bus device has 4 inputs for resistive temperature sensors. Functions: 180 µs A/D conversion time, measured value output in 16-bit values, 500 kbaud/2 Mbaud selection, PCP configuration, short-circuit/overload protection, M12 fast connection technology.

More details


Programmable Logic Controllers Plcs

AUTOMATION Industrial Automation - PHOENIX CONTACT

I/O systems. Connectors - PHOENIX CONTACT

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Quantity Price
1+$471.10
2+$458.41
3+$455.01
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Dimensions

Width70 mm
Height178 mm
Depth50 mm
Drill hole spacing168 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 60 °C
Ambient temperature (storage/transport)-25 °C ... 85 °C
Permissible humidity (storage/transport)95 %
Air pressure (operation)80 kPa ... 106 kPa (up to 2000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protectionIP65/IP67

General

Net weight280 g
Mounting typeWall mounting

Interfaces

DesignationFieldline local bus
Connection methodM12 connector, B-coded
Transmission speed500 kBit/s / 2 MBit/s
Transmission physicsCopper

Power supply for module electronics

Supply voltage24 V DC
Supply voltage range18 V DC ... 30 V DC (including ripple)

Fieldline potentials

Voltage supply UL24 V DC
Power supply at ULmax. 4 A
Current consumption from ULmax. 100 mA (At 2 Mbaud)
typ. 70 mA
Voltage supply US24 V DC
Power supply at USmax. 4 A
Current consumption from UStyp. 5 mA (plus power supply for sensors)
max. 400 mA

Analog inputs

Number of inputsmax. 4 (for resistance temperature detectors)
Connection methodM12 connector
2, 3, 4-wire (shielded)
Number of inputsmax. 4 (for resistance temperature detectors)
Connection methodM12 connector
2, 3, 4-wire (shielded)
Sensor types (RTD) that can be usedPt, Ni, KTY sensors, linear resistors
Process data updateDependent on the connection method
Input filter time4.1 ms (default setting or 0.6 ms; adjustable for each channel)

Datasheet - PDF

Title: Language: Size: Type:
PHOENIX CONTACT-2736819-FLM TEMP 4 RTD M12 English 111 Kbytes PHOENIX CONTACT-2736819-FLM TEMP 4 RTD M12

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.