PHOENIX CONTACT  DEK-TR/INV 2964319 - Image 1

Images are for illustrative purposes only. Please refer to data sheet for details.

DEK-TR/INV 2964319 PHOENIX CONTACT Switching amplifier

Reference: DEK-TR/INV

Code: 2964319

Manufacturer: PHOENIX CONTACT

Description:

Switching amplifier
Inverter module. The inverter module reverses the signals from the ground-connected NPN transistor outputs into positive-connected PNP outputs, as well as the PNP connection signals into NPN connection signals.

Categories:

  • Relays > Optocoupler
  • PHOENIX CONTACT > Industrial Relays

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX CONTACT

  • More Info
  • ETIM
  • PDF
  • Reviews
Guarantee, repair and return.

Unit Price: 22,75 €

This price is per unit and is the net value (not including taxes if applicable).

Calculate price by quantity

QuantityPrice

Standard lead time: 2-3 weeks.

  • These delivery times are an estimate any may vary when the item order has been processed.

LAST VIEWED

MORE INFO

Key Commercial Data

Orderkey2964319
Packing unit10 pc
Catalog pagePage 453 (C-5-2017)
GTIN4017918176068
Weight per Piece (excluding packing)19.900 g
Custom tariff number85364190
Country of originCN (China)

Dimensions

Width6.2 mm
Height80 mm
Depth56 mm

General

Supply voltage range20 V DC ... 30 V DC (UV)
Continuous current200 mA
Residual voltage drop< 1 V
Leakage current< 1 mA
Max. transmission frequency15 kHz

NPN input/PNP output

Switch-on threshold< 5 V (at UV= 24 V; < (UV- 19 V))
Switch-off threshold> 15 V (at UV= 24 V; > (UV- 9 V))
Min. limit values-2 V
Max. limit values26 V (at UV= 24 V; UV+ 2 V)

PNP input/NPN output

Switch-on threshold> 19 V
Switch-off threshold< 9 V
Min. limit values-2 V
Max. limit values26 V (at UV= 24 V; UV+ 2 V)

Connection data

Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.4 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Connection methodScrew connection
Stripping length8 mm
Screw threadM3

Ambient conditions

Ambient temperature (operation)-20 °C ... 50 °C
Ambient temperature (storage/transport)-20 °C ... 70 °C

General

Type of noteNote on application
NoteUse of EB 80-DIK... bridges in the DEK terminal blocks: Absorption of humidity from the ambient air as well as an unfavorable tolerance between a larger number of DEK terminal blocks and the EB 80-DIK... bridge may cause (minor) expansion of the DEK housing. When the EB 80-DIK... bridges are used, therefore, it is recommended that these be disconnected after about 10 to 12 DEK terminal blocks and a wire bridge to the next DEK terminal block be inserted in their place.

Standards and Regulations

Connection in acc. with standardCUL
Standards/regulationsIEC 60664

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

ETIM for 2964319 Relays (EC001504)

Feature nameWith LED indication (EF005950)
Feature valueNo

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.