Product successfully added to your shopping cart
IBS IL 24 RB-T-2MBD-PAC
2861962
PHOENIX_CONTACT
1
Branch terminal
INTERBUS branch terminal block, 2MBD, with accessories, with remote bus switch, 24 V DC
Inline, branch terminal, INTERBUS, Inline shield plug, with remote bus branch, transmission speed in the local bus: 2 Mbps, degree of protection: IP20, including Inline connector and marking field
PLC's > Fieldbus, decentr. periphery - communication module
I/O
Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Dimensional drawing | ![]() |
| Width | 12.2 mm |
| Height | 135 mm |
| Depth | 71.5 mm |
| Note on application | |
| Note on application | Only for industrial use |
| INTERBUS | |
| Connection method | Inline data jumper |
| Transmission speed | 2 Mbps |
| INTERBUS | |
| Connection method | Inline shield connector |
| Transmission speed | 2 Mbps |
| Transmission physics | RS-485 |
| Inline local bus | |
| Connection method | Inline data jumper |
| Transmission speed | 2 Mbps |
| Transmission physics | Copper |
| System limits | |
| Number of local bus devices that can be connected | max. 63 (Consider the logic current consumed by the devices; the branch terminal does not count as an Inline station device.) |
| Module | |
| ID code (dec.) | 04 |
| ID code (hex) | 04 |
| Length code (hex) | 0 |
| Length code (dec) | 0 |
| Process data channel | 0 bit |
| Input address area | 0 Byte |
| Output address area | 0 Byte |
| Register length | 0 bit |
| Required parameter data | 0 Byte |
| Required configuration data | 0 Byte |
| Product type | I/O component |
| Product family | Inline |
| Type | modular |
| Scope of delivery | including Inline connector and labeling field |
| Special properties | with remote bus branch |
| Data management status | |
| Article revision | 07 |
| Maximum power dissipation for nominal condition | 0.7 W |
| Potentials: Supply of analog modules (UANA) | |
| Supply voltage | 24 V DC (via voltage jumper) |
| Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
| Current draw | typ. 29 mA |
| Electrical isolation/isolation of the voltage ranges | |
| Test voltage: 5 V supply, incoming remote bus, electrically isolated from 5 V supply, outgoing remote bus | 500 V AC, 50 Hz, 1 min. |
| Test voltage: 5 V supply, incoming remote bus, electrically isolated from 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply, 5 V logics supply branch terminal block | 500 V AC, 50 Hz, 1 min. |
| Test voltage: 5 V supply, incoming remote bus, electrically isolated from 24 V main supply, 24 V segment supply | 500 V AC, 50 Hz, 1 min. |
| Test voltage: 5 V supply incoming remote bus / functional ground | 500 V AC, 50 Hz, 1 min. |
| Test voltage: 5 V supply, outgoing remote bus, electrically isolated from 5 V supply, incoming remote bus | 500 V AC, 50 Hz, 1 min. |
| Test voltage: 5 V supply, outgoing remote bus, electrically isolated from 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply, 5 V logics supply branch terminal block | 500 V AC, 50 Hz, 1 min. |
| Test voltage: 5 V supply, outgoing remote bus, electrically isolated from 24 V main supply, 24 V segment supply | 500 V AC, 50 Hz, 1 min. |
| Test voltage: 5 V supply outgoing remote bus, electrically isolated from functional ground | 500 V AC, 50 Hz, 1 min. |
| Test voltage: 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply, 5 V logics supply branch terminal block, electrically isolated from 5 V supply incoming remote bus | 500 V AC, 50 Hz, 1 min. |
| Test voltage: 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply, 5 V logics supply branch terminal block, electrically isolated from 5 V supply outgoing remote bus | 500 V AC, 50 Hz, 1 min. |
| Test voltage: 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply, 5 V logics supply branch terminal block, electrically isolated from 24 V main supply, 24 V segment supply | 500 V AC, 50 Hz, 1 min. |
| Test voltage: 7.5 V communications power, 24 V analog supply, 24 V bus terminal module supply, 5 V communications power, bus branch terminal electrically isolated from functional ground | 500 V AC, 50 Hz, 1 min. |
| Test voltage: 24 V main supply, 24 V segment supply, electrically isolated from 5 V supply, incoming remote bus | 500 V AC, 50 Hz, 1 min. |
| Test voltage: 24 V main supply, 24 V segment supply, electrically isolated from 5 V supply, outgoing remote bus | 500 V AC, 50 Hz, 1 min. |
| Test voltage: 24 V main supply, 24 V segment supply, electrically isolated from 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply, 5 V logics supply branch terminal block | 500 V AC, 50 Hz, 1 min. |
| Test voltage: 24 V main supply, 24 V segment supply, electrically isolated from the functional ground | 500 V AC, 50 Hz, 1 min. |
| Connection technology | |
| Connection name | Inline connector |
| Conductor connection | |
| Connection method | Spring-cage connection |
| Conductor cross section rigid | 0.08 mm² ... 1.5 mm² |
| Conductor cross section flexible | 0.08 mm² ... 1.5 mm² |
| Conductor cross section AWG | 28 ... 16 |
| Stripping length | 8 mm |
| Inline connector | |
| Connection method | Spring-cage connection |
| Conductor cross section, rigid | 0.08 mm² ... 1.5 mm² |
| Conductor cross section, flexible | 0.08 mm² ... 1.5 mm² |
| Conductor cross section AWG | 28 ... 16 |
| Stripping length | 8 mm |
| Ambient conditions | |
| Ambient temperature (operation) | -25 °C ... 55 °C |
| Degree of protection | IP20 |
| Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Ambient temperature (storage/transport) | -25 °C ... 85 °C |
| Permissible humidity (operation) | 10 % ... 95 % (according to DIN EN 61131-2) |
| Permissible humidity (storage/transport) | 10 % ... 95 % (according to DIN EN 61131-2) |
| Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
| Mounting type | DIN rail mounting |
| Feature Name | Feature Value |
|---|---|
| Supply voltage DC (EF007534) | 24 V |
| Supporting protocol for EtherCAT (EF017564) | No |
| Supporting protocol for EtherNet/IP (EF007521) | No |
| Radio standard Bluetooth (EF007178) | No |
| Radio standard WLAN 802.11 (EF007179) | No |
| Radio standard GPRS (EF008523) | No |
| IO link master (EF007298) | No |
| System accessory (EF004118) | Yes |
| Degree of protection (IP) (EF005474) | IP20 |
| With potential separation (EF003272) | Yes |
| Fieldbus connection over separate bus coupler possible (EF004002) | Yes |
| Suitable for rail mounting (EF003972) | Yes |
| Wall mounting/direct mounting (EF007020) | No |
| Front built-in possible (EF007016) | No |
| Rack-assembly possible (EF007018) | No |
| Suitable for safety functions (EF001597) | No |
| Performance level according to EN ISO 13849-1 (EF007399) | None |
| Appendant operation agent (Ex ia) (EF004141) | No |
| Appendant operation agent (Ex ib) (EF004142) | No |
| Explosion safety category for gas (EF003997) | None |
| Explosion safety category for dust (EF003998) | None |
| Width (EF000008) | 12.15 mm |
| Height (EF000040) | 136.04 mm |
| Depth (EF000049) | 70.51 mm |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG PHOENIX AUTOMATION EN.pdf | 35 Mbytes |
|
| PHOENIX CONTACT-2861962-IBS IL 24 RB-T-2MBD-PAC | 140 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.