ILB IB AI4 AO2 2878777 PHOENIX CONTACT Inline Block IO analog input/output module, INTERBUS, inputs: 0-20 mA.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

ILB IB AI4 AO2 2878777 PHOENIX CONTACT Inline Block IO analog input/output module, INTERBUS, inputs: 0-20 mA..

ILB IB AI4 AO2

2878777

PHOENIX_CONTACT

Available

Ship on today

Inline Block IO analog input/output module, INTERBUS, inputs: 0-20 mA, 4-20 mA, ±20 mA, 0-5 V, ±5 V,0-10 V, ±10 V, Pt 100, Pt 1000, Ni 1000..., outputs: 0-5 V, ±5 V, 0-10 V, ±10V, 0-20 mA, ±20 mA, 4-20 mA, 2, 3, 4-wire connection

More details


Programmable Logic Controllers Plcs

AUTOMATION Industrial Automation - PHOENIX CONTACT

I/O systems. Connectors - PHOENIX CONTACT

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Quantity Price
1+$786.38
2+$775.85
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Product description

The multifunctional, analog Inline Block I/O modules can be used universally. The four inputs either offer the difference measured between analog current / voltage signals or the option of connecting resistance thermometers (RTDs). Furthermore, the current or voltage actuators can be connected at the two outputs. In addition, all channels are equipped with shield connections as a standard and are provided with the 2, 3 or 4-conductor system. The analog signals are made available with a resolution of 16 bits.

The plugs can be labeled using hinged labeling fields. The fields have insert cards that can be labeled individually to suit the application. Additionally, there is the proven ZBFM-6... Zack marker strip for labeling the terminal points.

Dimensions

Width156 mm
Height141 mm
Depth57 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 60 °C
Ambient temperature (storage/transport)-25 °C ... 85 °C
Permissible humidity (operation)10 % ... 85 % (non-condensing)
Permissible humidity (storage/transport)10 % ... 95 % (non-condensing)
Air pressure (operation)80 kPa ... 108 kPa (up to 2000 m above sea level)
Air pressure (storage/transport)66 kPa ... 108 kPa (up to 3500 m above mean sea level)
Degree of protectionIP20

General

Net weight465 g
Mounting typeDIN rail

Interfaces

Fieldbus systemINTERBUS
DesignationInline local bus
Connection methodInline connector
Transmission speed500 kBit/s
Transmission physicsCopper

Inline potentials

Communications power UL24 V DC
Power supply at ULmax. 8 A
Current consumption from ULtyp. 100 mA
max. 175 mA (AO-I nominal load)
Segment supply voltage US24 V DC
Power supply at USmax. 8 A
Current consumption from USmax. 220 mA (Maximum full load)

Analog inputs

Number of inputsmax. 4 (Differential inputs, voltage or current can be chosen separately)
Connection methodSpring-cage connection
2, 3, 4-wire (shielded)
Input nameAnalog inputs
A/D conversion timetyp. 180 µs
Resolution A/D16 bit
Limit frequency (3 dB)120 Hz (default for 4.5 ms filter)
450 Hz (for 1.1 ms filter)
Measured value resolution16 bits (15 bits + sign bit)
Current input signal0 mA ... 20 mA
4 mA ... 20 mA
-20 mA ... 20 mA
Input resistance current inputtyp. 107 Ω
Voltage input signal0 V ... 5 V
-5 V ... 5 V
0 V ... 10 V
-10 V ... 10 V
Input resistance of voltage inputtyp. 276 kΩ
Number of inputs4 (differential inputs, voltage)
Type of protectionElectronic short-circuit protection
Open circuit responseGoes to 0 V
Voltage input signal0 V ... 5 V
-5 V ... 5 V
0 V ... 10 V
-10 V ... 10 V
Input resistance of voltage inputtyp. 276 kΩ
Number of inputs4 (Differential inputs, current)
Type of protectionElectronic short-circuit protection
Open circuit responseGoing to 0 mA; open-circuit detection from 4 mA ... 20 mA
Current input signal0 mA ... 20 mA
4 mA ... 20 mA
-20 mA ... 20 mA
Input resistance current inputtyp. 107 Ω
Number of inputs4
Input nameAnalog RTD inputs
Sensor types (RTD) that can be usedPt 100, Pt 500, Pt 1000, Ni 100, Ni 1000, Ni 1000 L&G
Linear resistance measuring range0 Ω ... 3200 Ω
0 Ω ... 9500 Ω
Protective circuitOverload protection, short-circuit protection of sensor supply

Analog outputs

Number of outputs2
Connection methodSpring-cage connection
2-wire (shielded)
Output nameAnalog outputs
D/A conversion timetyp. 70 µs
D/A resolution16 bit
Type of protectionShort-circuit protection of outputs
Protective circuit/componentElectronic
Data formatsIB IL, IB ST, IB RT, standardized representation, S7 compatible
Representation of output values16 bits (15 bits + sign)
Process data update17 ms
Current output signal0 mA ... 20 mA
4 mA ... 20 mA
-20 mA ... 20 mA
Load/output load current outputto 500 Ω
Voltage output signal0 V ... 5 V
-5 V ... 5 V
0 V ... 10 V
-10 V ... 10 V
Load/output load voltage output> 2 kΩ

Datasheet - PDF

Title: Language: Size: Type:
PHOENIX CONTACT-2878777-ILB IB AI4 AO2 English 144 Kbytes PHOENIX CONTACT-2878777-ILB IB AI4 AO2

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Últimas Opiniones de Nuestros Clientes

Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.