IB IL TEMP 2 UTH-XC-PAC 2701216 PHOENIX CONTACT Inline terminal View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

IB IL TEMP 2 UTH-XC-PAC 2701216 PHOENIX CONTACT Inline terminal

IB IL TEMP 2 UTH-XC-PAC

2701216

PHOENIX_CONTACT

Inline terminal

Inline, Temperature recording module, Analogue UTH inputs: 2 (Thermocouples or linear voltage), Connection technology: 2 conductors, transmission rate on local bus: 500 kBit/s, Variant Extreme Conditions, protection index: IP20, including Inline connector and marking surface

More details


PLC's > Fieldbus, decentr. periphery - analogue I/O module

I/O

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Best sellers

More info



Key Commercial Data

Orderkey2701216
Packing unit1 pc
Catalog pagePage 164 (C-6-2017)
GTIN4046356727846
Weight per Piece (excluding packing)105.000 g
Custom tariff number85389091
Country of originDE (Germany)

Note

Utilization restriction1

Dimensions

Dimensional drawing
Width12.2 mm
Height136.8 mm
Depth71.5 mm
Note on dimensionsHousing dimensions

Ambient conditions

Ambient temperature (operation)-25 °C ... 55 °C (Standard)
-40 °C ... 70 °C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)10 % ... 95 % (non-condensing)
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protectionIP20

General

Mounting typeDIN rail
Net weight105 g
Note on weight specificationswith connector
Operating modeProcess data operation with 2 words
Diagnostics messagesFailure of the internal I/O supply I/O error message sent to the bus coupler
Failure of or insufficient communications power ULI/O error message sent to the bus coupler
Peripheral fault Error message in the process data
User error Error message in the process data

Interfaces

DesignationInline local bus
No. of channels2
Connection methodInline data jumper
Transmission speed500 kbps

Inline potentials

DesignationCommunications power (UL)
Supply voltage7.5 V DC (via voltage jumper)
Current consumptiontyp. 43 mA
max. 60 mA
DesignationSupply of analog modules (UANA)
Supply voltage24 V DC (via voltage jumper)
Supply voltage range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current consumptiontyp. 11 mA
max. 18 mA
Power consumptiontyp. 587 mW

Analog inputs

Number of inputs2 (Thermocouples or linear voltage)
Input nameAnalog UTH inputs
Description of the inputInputs for thermocouples or linear voltage
Connection methodInline connector
Connection technology2-wire
Note regarding the connection technologyShielded compensating line for TC with encapsulated sensors
Sensor types that can be used (TC)U, T, L, J, E, K, N, S, R, B, C, W, HK
Measuring principleSuccessive approximation
Measured value representation16 bits (15 bits + sign bit)
A/D conversion timetyp. 120 µs (per channel)
Process data updatemax. 30 ms (For both channels)
Type of protectionSurge protection (TC channels)

Electrical isolation

Test section7.5 V supply (bus logics)/24 V analog supply (analog I/O) 500 V AC 50 Hz 1 min.
7.5 V supply (bus logics) / functional earth ground 500 V AC 50 Hz 1 min.
24 V analog supply (analog I/O) / functional earth ground 500 V AC 50 Hz 1 min.

Standards and Regulations

Connection in acc. with standardCUL
Protection classIII, IEC 61140, EN 61140, VDE 0140-1

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications


ETIM for 2701216 PLC's (EC001596)
Feature Name Feature Value
Supply voltage DC (EF007534) 19.2 V
Voltage type (supply voltage) (EF002991) DC
Input, current (EF003204) No
Input, voltage (EF003205) No
Input, resistor (EF003206) No
Input, resistance thermometer (EF003207) No
Input, thermocouple (EF003208) Yes
Input signal, configurable (EF003209) No
Output, current (EF003212) No
Output, voltage (EF003213) No
Output signal configurable (EF003214) No
Number of analogue inputs (EF001994) 0
Number of analogue outputs (EF001995) 0
Analogue inputs configurable (EF008518) No
Analogue outputs configurable (EF008519) No
Number of HW-interfaces industrial Ethernet (EF003020) 0
Number of interfaces PROFINET (EF006932) 0
Number of HW-interfaces RS-232 (EF003021) 0
Number of HW-interfaces RS-422 (EF003022) 0
Number of HW-interfaces RS-485 (EF003023) 0
Number of HW-interfaces serial TTY (EF003024) 0
Number of HW-interfaces parallel (EF003026) 0
Number of HW-interfaces wireless (EF006933) 0
Number of HW-interfaces USB (EF003025) 0
Number of HW-interfaces other (EF003027) 0
Supporting protocol for EtherCAT (EF017564) No
Supporting protocol for TCP/IP (EF003050) No
Supporting protocol for PROFIBUS (EF003052) No
Supporting protocol for CAN (EF003053) No
Supporting protocol for INTERBUS (EF003054) No
Supporting protocol for ASI (EF003051) No
Supporting protocol for KNX (EF003055) No
Supporting protocol for Modbus (EF003057) No
Supporting protocol for Data-Highway (EF003058) No
Supporting protocol for DeviceNet (EF003059) No
Supporting protocol for SUCONET (EF003060) No
Supporting protocol for LON (EF003017) No
Supporting protocol for PROFINET IO (EF007525) No
Supporting protocol for PROFINET CBA (EF007524) No
Supporting protocol for SERCOS (EF006657) No
Supporting protocol for Foundation Fieldbus (EF007522) No
Supporting protocol for EtherNet/IP (EF007521) No
Supporting protocol for AS-Interface Safety at Work (EF007519) No
Supporting protocol for DeviceNet Safety (EF007520) No
Supporting protocol for INTERBUS-Safety (EF006662) No
Supporting protocol for PROFIsafe (EF007526) No
Supporting protocol for SafetyBUS p (EF007527) No
Supporting protocol for other bus systems (EF003062) Yes
Radio standard Bluetooth (EF007178) No
Radio standard WLAN 802.11 (EF007179) No
Radio standard GPRS (EF008523) No
Radio standard GSM (EF008524) No
Radio standard UMTS (EF008525) No
IO link master (EF007298) No
System accessory (EF004118) Yes
Degree of protection (IP) (EF005474) IP20
Type of electric connection (EF003961) Other
Fieldbus connection over separate bus coupler possible (EF004002) Yes
Suitable for rail mounting (EF003972) Yes
Wall mounting/direct mounting (EF007020) Yes
Front built-in possible (EF007016) No
Rack-assembly possible (EF007018) No
Suitable for safety functions (EF001597) No
Performance level according to EN ISO 13849-1 (EF007399) None
Appendant operation agent (Ex ia) (EF004141) No
Appendant operation agent (Ex ib) (EF004142) No
Explosion safety category for gas (EF003997) None
Explosion safety category for dust (EF003998) None
Width (EF000008) 12.15 mm
Height (EF000040) 138.44 mm
Depth (EF000049) 70.51 mm

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.