IB IL TEMP 4/8 RTD-PAC 2863915 PHOENIX CONTACT Inline function terminal View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

IB IL TEMP 4/8 RTD-PAC 2863915 PHOENIX CONTACT Inline function terminal

IB IL TEMP 4/8 RTD-PAC

2863915

PHOENIX_CONTACT

Inline function terminal

More details


I/O

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total price: $543.86
Unit price: $543.86

Quantity Price
1+$543.86
2+$498.60
3+$481.94
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Often bought together

More info



Key Commercial Data

Orderkey2863915
Packing unit1 pc
Catalog pagePage 165 (C-6-2017)
GTIN4017918955410
Weight per Piece (excluding packing)190.000 g
Custom tariff number85389091
Country of originDE (Germany)

Note

Utilization restriction1

Dimensions

Dimensional drawing
Width48.8 mm
Height136.8 mm
Depth71.5 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 55 °C
Ambient temperature (storage/transport)-25 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (according to DIN EN 61131-2)
Permissible humidity (storage/transport)10 % ... 95 % (according to DIN EN 61131-2)
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protectionIP20

General

Mounting typeDIN rail
Net weight190 g
Operating modeProcess data mode with 5 words/1 word PCP

Interfaces

DesignationInline local bus
Connection methodInline data jumper
Transmission speed500 kbps
Transmission physicsCopper

Inline potentials

DesignationCommunications power (UL)
Supply voltage7.5 V DC (via voltage jumper)
Current consumptiontyp. 75 mA
max. 100 mA
DesignationSupply of analog modules (UANA)
Supply voltage24 V DC (via voltage jumper)
Supply voltage range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current consumptiontyp. 28 mA
max. 55 mA
Power consumptiontyp. 1.24 W

Analog inputs

Number of inputs8
Input nameAnalog RTD inputs
Description of the inputInput for resistive temperature sensors
Connection methodSpring-cage connection
Connection technology2, 3-conductor
Sensor types (RTD) that can be usedPt, Ni, KTY, Cu sensors, linear resistors
Linear resistance measuring range0 Ω ... 400 Ω
0 Ω ... 20 kΩ
Measuring principleSuccessive approximation
Measured value representation16 bits (15 bits + sign bit)
A/D conversion timemax. 10 µs
Process data update6 ms (Up to 230 ms possible depending on operating mode)
Data formatsIB IL, IB ST, S7 compatible

Electrical isolation

Test section7.5 V supply (bus logic)/±15.5 V, ±5 V analog supply (analog I/O) 500 V AC 50 Hz 1 min.
7.5 V supply (bus logics) / functional earth ground 500 V AC 50 Hz 1 min.
±15.5 V, ±5 V analog supply (analog I/O)/functional earth ground 500 V AC 50 Hz 1 min.

Standards and Regulations

Protection classIII, IEC 61140, EN 61140, VDE 0140-1

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.