IB IL AI 2-HART-PAC 2862149 PHOENIX CONTACT Inline analog input terminal block, complete with accessories (c.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

IB IL AI 2-HART-PAC 2862149 PHOENIX CONTACT Inline analog input terminal block, complete with accessories (c..

IB IL AI 2-HART-PAC

2862149

PHOENIX_CONTACT

Available

Ship on today

Inline analog input terminal block, complete with accessories (connector and labeling field), 2 inputs, 0-25 mA, 4-20 mA, 2-wire connection technology, HART functions, HART protocol transmission

More details


Programmable Logic Controllers Plcs

AUTOMATION Industrial Automation - PHOENIX CONTACT

I/O systems. Connectors - PHOENIX CONTACT

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Quantity Price
1+$592.49
2+$578.05
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Dimensions

Width48.8 mm
Height135 mm
Depth71.5 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 55 °C
Ambient temperature (storage/transport)-25 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (according to DIN EN 61131-2)
Permissible humidity (storage/transport)10 % ... 95 % (according to DIN EN 61131-2)
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protectionIP20

General

Net weight134 g
Mounting typeDIN rail

Interfaces

Fieldbus systemLokalbus
DesignationInline local bus
Connection methodInline data jumper
Transmission speed500 kBit/s
Transmission physicsCopper

Inline potentials

Communications power UL7.5 V DC
Current consumption from ULmax. 110 mA
typ. 95 mA
Current consumption from US0 A DC
I/O supply voltage UANA24 V DC
Current consumption from UANAmax. 150 mA
typ. 50 mA
Power consumptiontyp. 1.9 W

Analog inputs

Number of inputsmax. 2 (Differential inputs, current)
Connection methodInline shield connector
2-wire (shielded)
Input nameAnalog inputs
A/D conversion timeapprox. 10 µs (bus-synchronous)
Limit frequency (3 dB)25 Hz
Data formatsIL, standardized representation
Measuring principleSuccessive approximation
Measured value resolution16 bits (15 bits + sign bit)
Measured value representation16 bit two's complement
Current input signal4 mA ... 20 mA
0 mA ... 25 mA
Number of inputs2 (Differential inputs, current)
Current input signal4 mA ... 20 mA
0 mA ... 25 mA
Input resistance current input250 Ω

Datasheet - PDF

Title: Language: Size: Type:
PHOENIX CONTACT-2862149-IB IL AI 2-HART-PAC English 143 Kbytes PHOENIX CONTACT-2862149-IB IL AI 2-HART-PAC

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Últimas Opiniones de Nuestros Clientes

Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.