IB IL RS UNI-2MBD-PAC 2701025 PHOENIX CONTACT Inline function terminal View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

IB IL RS UNI-2MBD-PAC 2701025 PHOENIX CONTACT Inline function terminal

IB IL RS UNI-2MBD-PAC

2701025

PHOENIX_CONTACT

Inline function terminal

Inline communication terminal block, for serial data transmission, complete with accessories (connector and marking surface), 1 serial input and output channel in RS-485/422- or RS-232 execution, transmission speed 2 MBaud

Inline, Communication terminal, interface RS-232, RS-485, RS-422: 1 (be operated simultaneously), transmission speed in the local bus: 2 Mbps, degree of protection: IP20, including Inline connectors and marking fields

More details


I/O

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Technical data

Dimensions
Dimensional drawingnmwuvoqfyi.jpg
Width24.3 mm
Height135.4 mm
Depth71.5 mm

Notes
Note on application
Note on applicationOnly for industrial use

Interfaces
Inline local bus
Number of interfaces2
Connection methodInline data jumper
Transmission speed2 Mbps
RS-232, RS-485, RS-422
Number of interfaces1 (be operated simultaneously)
Connection methodSpring-cage connection
Note on the connection methodUse shielded cables.
Transmission speed110 bps ... 250000 bps (can be parameterized)
Transmission physicsCopper
Protocols supportedTransparent, end-to-end, XON/XOFF
Termination resistortyp. 120 Ω (active, integrated)
Data bits5 ... 8
Stop bits1 or 2
Input buffer4 kByte
Output buffer1 kByte

System properties
Module
ID code (dec.)223
ID code (hex)DF
Length code (hex)1F
Length code (dec)31
Process data channel496 bit
Input address areamax. 62 Byte
Output address areamax. 62 Byte
Register length64 Byte
Required parameter data23 Byte
Required configuration data5 Byte

Product properties
Product typeI/O component
Product familyInline
Typemodular
Scope of deliveryincluding Inline connectors and marking fields
Insulation characteristics
Overvoltage categoryII (IEC 60664-1, EN 60664-1)
Pollution degree2 (IEC 60664-1, EN 60664-1)

Electrical properties
Maximum power dissipation for nominal conditionmax. 1.3 W
Potentials
Power consumptionmax. 1.3 W (at ULand UM, within the permissible operating temperature)
Potentials: Communications power (UL)
Supply voltage7.5 V DC (via voltage jumper)
Current drawmax. 90 mA (all connections of the serial interface are short-circuited)
typ. 78 mA
Power consumptiontyp. 585 mW
Potentials: Main circuit supply (UM)
Supply voltage24 V DC (via voltage jumper)
Current drawmax. 25 mA
typ. 15 mA
Electrical isolation/isolation of the voltage ranges
Test voltage: Serial interface/7.5 V supply (bus logic)500 V AC, 50 Hz, 1 min.
Test voltage: Serial interface/24 V supply UM500 V AC, 50 Hz, 1 min.
Test voltage: Serial interface/functional ground500 V AC, 50 Hz, 1 min.
Test voltage: 7.5 V supply (bus logic)/functional ground500 V AC, 50 Hz, 1 min.
Test voltage: 24 V supply (UM)/functional ground500 V AC, 50 Hz, 1 min.

Connection data
Connection technology
Connection nameInline connector
Conductor connection
Connection methodSpring-cage connection
Conductor cross section rigid0.08 mm² ... 1.5 mm²
Conductor cross section flexible0.08 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16
Stripping length8 mm
Inline connector
Connection methodSpring-cage connection
Conductor cross section, rigid0.08 mm² ... 1.5 mm²
Conductor cross section, flexible0.08 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16
Stripping length8 mm

Environmental and real-life conditions
Ambient conditions
Ambient temperature (operation)-25 °C ... 55 °C
Degree of protectionIP20
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)-25 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)10 % ... 95 % (non-condensing)

Standards and regulations
Protection classIII (IEC 61140, EN 61140, VDE 0140-1)

Mounting
Mounting typeDIN rail mounting

Datasheet - PDF

Title: Size: Type:
PDF CATALOG PHOENIX AUTOMATION EN.pdf 35 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.