Product successfully added to your shopping cart
RAD-DAIO6-IFS
2901533
PHOENIX_CONTACT
1
I/O extension module
Radioline: I/O expansion module, 2 digital inputs and outputs (0 ... 250 V AC/DC) and 1 analog input (0/4 ... 20 mA) and analog output (0/4 ... 20 mA, 0 ... 10 V)
PLC's > Fieldbus, decentr. periphery - analogue/digital I/O module
Safety
Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Orderkey | 2901533 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 460 (C-6-2017) |
| GTIN | 4046356610216 |
| Weight per Piece (excluding packing) | 240.000 g |
| Custom tariff number | 85177000 |
| Country of origin | DE (Germany) |
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
| Degree of protection | IP20 |
|---|---|
| Ambient temperature (operation) | -40 °C ... 70 °C (>55°C derating) |
| -40 °F ... 158 °F (>131°F derating) | |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| -40 °F ... 185 °F | |
| Permissible humidity (operation) | 20 % ... 85 % |
| Permissible humidity (storage/transport) | 20 % ... 85 % |
| Altitude | 2000 m |
| Vibration (operation) | in accordance with IEC 60068-2-6: 5g, 10 Hz ... 150 Hz |
| Shock | 16g, 11 ms |
| Overvoltage category | II |
|---|---|
| Mounting position | any |
| Assembly instructions | on standard DIN rail NS 35 in accordance with EN 60715 |
| Degree of pollution | 2 |
| Housing material | PA 6.6-FR |
| Flammability rating according to UL 94 | V0 |
| MTTF | 889 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) |
| 391 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day)) | |
| 151 Years (Telcordia standard, temperature 40 °C, operating cycle 100 % (7 days a week, 24 hours a day)) |
| Supply voltage range | 19.2 V DC ... 30.5 V DC (DIN rail connector) |
|---|---|
| Max. current consumption | ≤ 95 mA (At 24 V DC, at 25°C) |
| Transient surge protection | Yes |
| Number of inputs | 1 |
|---|---|
| Current input signal | 0 mA ... 20 mA (can be set via DIP switches) |
| 4 mA ... 20 mA (can be set via DIP switches) | |
| Max. current input signal | 22 mA |
| Input resistance current input | < 70 Ω |
| Precision | ≤ 0.02 % (at 25 °C) |
| Temperature coefficient, typical | typ. 0.0025 %/K (at -40 °C ... +70 °C) |
| Supply voltage | ≥ 12 V DC (For passive sensors (via terminal PWR1, +I1)) |
| Resolution | 16 bit |
| Protective circuit | Short-circuit and overload protection |
| Description of the input | Digital input |
|---|---|
| Number of inputs | 2 |
| Switching level "1" signal | 10 V AC/DC ... 50 V AC/DC (Low-voltage input) |
| 50 V AC/DC ... 250 V AC/DC (High-voltage input) | |
| Switching level "0" signal | 0 V AC/DC ... 4 V AC/DC (Low-voltage input) |
| 0 V AC/DC ... 20 V AC/DC (High-voltage input) | |
| Input frequency | ≤ 2 Hz |
| Number of outputs | 1 |
|---|---|
| Voltage output signal | 0 V ... 10 V |
| Max. voltage output signal | approx. 10.83 V |
| Load | ≥ 10 kΩ |
| Precision | typ. 0.5 % (Voltage output) |
| Current output signal | 0 mA ... 20 mA |
| 4 mA ... 20 mA | |
| Max. current output signal | approx. 21.67 mA |
| Load | ≤ 500 Ω |
| Precision | ≤ 0.02 % (at 25 °C) |
| Resolution | 16 bit |
| Temperature coefficient, typical | typ. 0.0025 %/K (at -40 °C ... +70 °C) |
| Behavior of the outputs (adjustable via DIP switch) | Hold / Reset |
| Protective circuit | Transient protection of outputs |
| Number of outputs | 2 |
|---|---|
| Contact type | PDT |
| Contact material | AgSnO2 |
| Maximum switching voltage | 250 V AC/DC |
| Min. switching current | ≥ 10 mA |
| Max. switching current | 2 A (per channel) |
| Mechanical service life | 1x 107cycles |
| Electrical service life | 2x 105cycles (At 2 A, 250 V AC, cosφ 0.4) |
| 2x 105cycles (At 1 A, 24 V DC, L/R = 48 ms) | |
| Maximum switching frequency | 2 Hz |
| Switching capacity | 120 W (24 V DC) |
| 120 W (30 V DC) | |
| 20 W (48 V DC) | |
| 18 W (60 V DC) | |
| 22 W (110 V DC) | |
| 40 W (220 V DC) | |
| 42 W (250 V DC) | |
| 1250 VA | |
| Behavior of the outputs (adjustable via DIP switch) | Hold / Reset |
| Digital I/O | 300 V (Rated insulation voltage (in each case between the digital inputs // digital outputs // TBUS supply, reinforced insulation according to EN 61010)) |
|---|---|
| Analog I/O | 50 V (Rated insulation voltage (in each case between the TBUS analog inputs / analog outputs / supply, reinforced insulation according to EN 61010)) |
| Digital/analog I/O | 300 V (Rated insulation voltage (in each case between the digital inputs and outputs and between the analog inputs and outputs, reinforced insulation according to EN 61010)) |
| Connection method | Screw connection |
|---|---|
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 2.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 14 |
| Stripping length | 7 mm |
| Tightening torque | 0.6 Nm |
| Screw thread | M3 |
| Status display | Green LED (supply voltage, PWR) |
|---|---|
| Green LED (bus communication, DAT) | |
| Red LED (periphery error, ERR) | |
| Yellow LED (digital input, DI1) | |
| Yellow LED (digital input, DI2) | |
| Yellow LED (digital output, DO1) | |
| Yellow LED (digital output, DO2) |
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
|---|---|
| Standard designation | EMC Directive 2014/30/EU |
| Standards/regulations | EN 61000-6-2 |
| Standard designation | EMC Directive 2014/30/EU |
| Standards/regulations | EN 61000-6-4 |
| Standard designation | Ex Directive (ATEX) |
| Standards/regulations | EN 60079-0 |
| Standard designation | Ex Directive (ATEX) |
| Standards/regulations | EN-60079-15 |
| Flammability rating according to UL 94 | V0 |
| Shock | 16g, 11 ms |
| Vibration (operation) | in accordance with IEC 60068-2-6: 5g, 10 Hz ... 150 Hz |
| Conformance | CE-compliant |
| ATEX | II 3 G Ex nA nC IIC T4 Gc |
| IECEx | Ex nA nC IIC T4 Gc |
| UL, USA/Canada | UL 508 Listed |
| Class I, Div. 2, Groups A, B, C, D T4A | |
| Class I, Zone 2, IIC T4 | |
| Noxious gas test | ISA-S71.04-1985 G3 Harsh Group A |
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Feature Name | Feature Value |
|---|---|
| Analogue inputs configurable (EF008518) | No |
| Analogue outputs configurable (EF008519) | No |
| Number of digital inputs (EF001992) | 0 |
| Number of digital outputs (EF001993) | 0 |
| Digital inputs configurable (EF008516) | No |
| Digital outputs configurable (EF008520) | No |
| Type of voltage (input voltage) (EF003033) | DC |
| Short-circuit protection, digital outputs available (EF003320) | No |
| Analogue input, current (EF003219) | No |
| Analogue input, voltage (EF003221) | No |
| Analogue input, resistor (EF003222) | No |
| Analogue input, resistor temperature (EF003224) | No |
| Analogue input, thermocouple (EF003225) | No |
| Analogue input signal configurable (EF003227) | No |
| Analogue output, current (EF003234) | No |
| Analogue output, voltage (EF003235) | No |
| Analogue output signal configurable (EF003236) | No |
| Number of HW-interfaces industrial Ethernet (EF003020) | 0 |
| Number of interfaces PROFINET (EF006932) | 0 |
| Number of HW-interfaces RS-232 (EF003021) | 0 |
| Number of HW-interfaces RS-422 (EF003022) | 0 |
| Number of HW-interfaces RS-485 (EF003023) | 0 |
| Number of HW-interfaces serial TTY (EF003024) | 0 |
| Number of HW-interfaces parallel (EF003026) | 0 |
| Number of HW-interfaces wireless (EF006933) | 0 |
| Number of HW-interfaces other (EF003027) | 0 |
| With optical interface (EF003028) | No |
| IO link master (EF007298) | No |
| System accessory (EF004118) | Yes |
| Degree of protection (IP) (EF005474) | IP20 |
| Fieldbus connection over separate bus coupler possible (EF004002) | Yes |
| Wall mounting/direct mounting (EF007020) | No |
| Front built-in possible (EF007016) | No |
| Rack-assembly possible (EF007018) | No |
| Suitable for safety functions (EF001597) | No |
| Appendant operation agent (Ex ia) (EF004141) | No |
| Appendant operation agent (Ex ib) (EF004142) | No |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE AUTOMATION PHOENIX EN.pdf | 35 Mbytes |
|
| PHOENIX CONTACT-2901533-RAD-DAIO6-IFS | 917 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.