HC-D 64-ESTC-R 1679498 PHOENIX CONTACT HEAVYCON male insert, D64 series, 64-pos., crimp connection, rolled c.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

HC-D 64-ESTC-R 1679498 PHOENIX CONTACT HEAVYCON male insert, D64 series, 64-pos., crimp connection, rolled c..

HC-D 64-ESTC-R

1679498

PHOENIX_CONTACT

10

Available

Ship on today

HEAVYCON male insert, D64 series, 64-pos., crimp connection, rolled contacts

More details


Core End Sleeves Cable Crimp

PLUSCON Field cabling - PHOENIX CONTACT

Heavy industrial connectors - PLUSCON heavy - PHOENIX CONTACT

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Quantity Price
10+$16.25
20+$15.70
30+$15.44
40+$15.28
60+$15.15
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



General

NoteFor HEAVYCON ADVANCE housings of B24 type and HEAVYCON housings of B24/48 types, crimp contacts CK1,6-ER / CK1,6-BR (crimp contacts not included in the scope of supply)
Connection methodCrimp connection
Pollution degree3
Overvoltage categoryIII
Constructional and testing regulationsDIN VDE 0627/86
DIN VDE 0110/02.79
DIN VDE 0110-1/04.97
IEC 60664-1, DIN IEC 60512
IEC 60352
Number of positions64+PE
Insertion/withdrawal cycles≥ 500
TypeB24
Connection in acc. with standardIEC / EN
Conductor cross section0.14 mm² ... 1.5 mm²
Connection cross section AWG26 ... 16
Stripping length of the individual wire3 mm +0,5 mm (0.14 mm² ... 0.5 mm²)
3.5 mm +1 (0.5 mm² ... 1.5 mm²)
Assembly instructions- Use of HC-CST (1676857) coding pins and HC-CBU (1676860) coding sockets has been prescribed.
ConnectionConnectors may be plugged in only when there is no load/voltage.

Ambient conditions

Ambient temperature (operation)-40 °C ... 125 °C (including heating up of contacts)

Material data

Flammability rating according to UL 94V0
Contact materialCopper alloy
Contact surface materialAg (alternatively Au)
Contact carrier materialPC

Electrical characteristics

Rated voltage (III/3)250 V
Rated surge voltage4 kV
Rated current10 A

Datasheet - PDF

Title: Language: Size: Type:
PHOENIX CONTACT-1679498-HC-D 64-ESTC-R English 135 Kbytes PHOENIX CONTACT-1679498-HC-D 64-ESTC-R

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Últimas Opiniones de Nuestros Clientes

Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.