FO converters
Fiber optic adapter (spare device B), for 10/100Base-T(X) duplex transmission to single Simplex fiberglass with WDM (Wavelength Division Multiplex) technology, SC Simplex fiber optic connection (1550/1310nm). Set of devices necessary for the service (model A and model B).
Data and telecommunication > Media converter
Safety
Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Orderkey | 2902659 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 336 (C-6-2017) |
| GTIN | 4046356669696 |
| Weight per Piece (excluding packing) | 120.000 g |
| Custom tariff number | 85176200 |
| Country of origin | DE (Germany) |
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
| Ambient temperature (operation) | -40 °C ... 65 °C |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Permissible humidity (operation) | 30 % ... 95 % (non-condensing) |
| Permissible humidity (storage/transport) | 30 % ... 95 % (non-condensing) |
| Altitude | 5000 m (For restrictions see manufacturer's declaration) |
| 2000 m (With UL approval) | |
| Degree of protection | IP20 |
| Electrical isolation | according to IEEE 802.3 |
|---|---|
| VCC // FE // Ethernet | |
| Latency | ± 1.3 µs (Store&Forward mode, 10/100 Mbps, depending on the frame size) |
| Test voltage data interface/power supply | 1.5 kVrms(50 Hz, 1 min.) |
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
| Net weight | 120 g |
| Housing material | PA 6.6-FR |
| Color | green |
| MTBF | 492 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) |
| 133 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day)) | |
| Conformance | CE-compliant |
| ATEX | II 3 G Ex nA IIC T4 Gc X (Please follow the special installation instructions in the documentation!) |
| UL, USA/Canada | cULus listed UL 508 |
| Class I, Zone 2, AEx nA IIC T4 | |
| Class I, Zone 2, Ex nA IIC T4 Gc X | |
| Class I, Div. 2, Groups A, B, C, D |
| Nominal supply voltage | |
|---|---|
| Supply voltage range | 18 V DC ... 30 V DC (Screw connection) |
| 18 V DC ... 30 V DC (as an alternative or redundant, via backplane bus contact and system current supply) | |
| Typical current consumption | < 110 mA (24 V DC) |
| Protective circuit | Reverse polarity protection |
| Connection method | Plug-in screw terminal block (COMBICON), redundancy possible |
| Conductor cross section flexible max. | 2.50 mm² |
| Conductor cross section flexible min. | 0.20 mm² |
| Conductor cross section solid max. | 2.50 mm² |
| Conductor cross section solid min. | 0.20 mm² |
| Max. AWG conductor cross section, flexible | 14 |
| Min. AWG conductor cross section, flexible | 24 |
| Conductor cross section AWG max. | 14 |
| Conductor cross section AWG min. | 24 |
| Interface 1 | Ethernet interface, 10/100Base-T(X) in acc. with IEEE 802.3u |
|---|---|
| No. of ports | 1 |
| Connection method | RJ45 socket, shielded |
| Transmission medium | Copper |
| Transmission length | 100 m (shielded twisted pair) |
| Auto-negotiation modes | Auto |
| Link through | Link fault pass through |
| Basic functions | Store-and-forward media converter |
| MDI-/MDI-X switchover | Auto-MDI(X) |
| Signal LEDs | Activity, link status, 10/100 Mbps |
| Transmit capacity, minimum | ≥ ((9/125 µm) dynamic in link mode (average)) |
|---|---|
| Transmit capacity, maximum | ≤ -8 dBm ((9/125 µm) dynamic in link mode (average)) |
| Minimum receiver sensitivity | min. -31 dBm (dynamic in link mode (average)) |
| Overrange receiver | -3 dBm (dynamic in link mode (average)) |
| Wavelength | 1310 nm (Send) |
| 1550 nm (Receiving) | |
| Transmission length incl. 3 dB system reserve | 38 km (With F-E 9/125 0.36 dB/km) |
| 34 km (With F-E 9/125 0.4 dB/km) | |
| 28 km (With F-E 9/125 0.5 dB/km) | |
| 21 km (with F-G 62,5/125 0,7 dB/km F 1000) | |
| 5.5 km (with F-G 62.5/125 2.6 dB/km F 600) | |
| 21 km (with F-G 50/125 0,7 dB/km F 1200) | |
| 9 km (with F-G 50/125 1,6 dB/km F 800) | |
| Transmission medium | Multi-mode fiberglass |
| Single-mode fiberglass | |
| Connection method | SC simplex |
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
|---|---|
| Type of test | Free fall in acc. with IEC 60068-2-32 |
| Test result | 1 m |
| Type of test | Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 |
| Test result | 5g, 10...150 Hz, 2.5 h, in XYZ direction |
| Type of test | Shock in acc. with EN 60068-2-27/IEC 60068-2-27 |
| Test result | 25g, 11 ms period, half-sine shock pulse |
| Free from substances that could impair the application of coating | according to P-VW 3.10.7 57 65 0 VW-AUDI-Seat central standard |
| Standards/regulations | EN 61000-4-2 |
| Contact discharge | ± 6 kV (Test Level 3) |
| Indirect discharge | ± 6 kV |
| Standards/regulations | EN 61000-4-3 |
| Frequency range | 80 MHz ... 3 GHz (Test Level 3) |
| Standards/regulations | EN 61000-4-4 |
| Comments | Criterion B |
| Standards/regulations | EN 61000-4-5 |
| Signal | ± 1 kV (Data line, asymmetrical) |
| Standards/regulations | EN 55032 |
| EN 61000-4-6 | |
| Frequency range | 0.15 MHz ... 80 MHz |
| Designation | Air clearances and creepage distances |
| Standards/regulations | EN 60950-1 |
| Electrical isolation | according to IEEE 802.3 |
| Conformance | CE-compliant |
| ATEX | II 3 G Ex nA IIC T4 Gc X |
| UL, USA/Canada | cULus listed UL 508 |
| Class I, Zone 2, AEx nA IIC T4 | |
| Class I, Zone 2, Ex nA IIC T4 Gc X | |
| Class I, Div. 2, Groups A, B, C, D | |
| DNV GL-Temperature | B |
| DNV GL-Humidity | A |
| DNV GL-Vibration | A |
| DNV GL-EMC | B |
| DNV GL-Enclosure | Required protection according to the Rules shall be provided upon installation on board |
| Noxious gas test | ISA-S71.04-1985 G3 Harsh Group A |
| Shipbuilding approval | DNV GL |
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Feature Name | Feature Value |
|---|---|
| Ethernet (EF003535) | No |
| Fast Ethernet (EF003536) | No |
| Gigabit Ethernet (EF003546) | No |
| Power over Ethernet (EF005178) | Yes |
| Voltage type (supply voltage) (EF002991) | DC |
| Supply voltage DC (EF007534) | 18 V |
| Height (EF000040) | 99 mm |
| Width (EF000008) | 22.6 mm |
| Depth (EF000049) | 114.2 mm |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE AUTOMATION PHOENIX EN.pdf | 35 Mbytes |
|
| PHOENIX CONTACT-2902659-FL MC EF WDM-B SC | 214 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.