Product successfully added to your shopping cart
FL MC EF 1300 MM SC
2902853
PHOENIX_CONTACT
1
FO converter with SC duplex fiber optic connection (1300 nm), for converting 10/100Base-T(X) to multi-mode fiberglass (50/125 µm). Auto negotiation and auto MDI(X) function. Comprehensive link diagnostics. DIN-rail mountable, 18 ... 30 V DC supply.
Safety
* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Width | 22.5 mm |
---|---|
Height | 99 mm |
Depth | 114.5 mm |
Ambient temperature (operation) | -40 °C ... 65 °C |
---|---|
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Permissible humidity (operation) | 30 % ... 95 % (non-condensing) |
Permissible humidity (storage/transport) | 30 % ... 95 % (non-condensing) |
Altitude | 5000 m (For restrictions see manufacturer's declaration) |
2000 m (With UL approval) | |
Degree of protection | IP20 |
Electrical isolation | according to IEEE 802.3 |
---|---|
VCC // FE // Ethernet | |
Latency | ± 1.3 µs (Store&Forward mode, 10/100 Mbps, depending on the frame size) |
Test voltage data interface/power supply | 1.5 kVrms(50 Hz, 1 min.) |
Standards/regulations | EN 60950-1 |
Electromagnetic compatibility | Conformance with EMC Directive 2004/108/EC (valid until 19.04.2016) / 2014/30/EU (valid from 20.04.2016) |
Net weight | 179 g |
Housing material | PA 6.6-FR |
Color | green |
MTBF | 479 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) |
140 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day)) | |
MTTF | 1400 Years (SN 29500 standard, temperature 25°C, operating cycle 21 % (5 days a week, 8 hours a day)) |
599 Years (SN 29500 standard, temperature 40 °C, operating cycle 34.25 % (5 days a week, 12 hours a day)) | |
101 Years (SN 29500 standard, temperature 40°C, operating cycle 100 % (7 days a week, 24 hours a day)) | |
Conformance | CE-compliant |
ATEX | Ex II 3 G Ex nA IIC T4 Gc X (Please follow the special installation instructions in the documentation!) |
Ex II (2) D [Ex op is Db] IIIC (PTB 06 ATEX 2042 U) (Please follow the special installation instructions in the documentation!) | |
Ex II (2) G [Ex op is Gb] IIC (PTB 06 ATEX 2042 U) (Please follow the special installation instructions in the documentation!) | |
UL, USA / Canada | cULus listed UL 508 |
Class I, Zone 2, AEx nA IIC T4 | |
Class I, Zone 2, Ex nA IIC T4 Gc X | |
Class I, Div. 2, Groups A, B, C, D |
Supply voltage range | 18 V DC ... 30 V DC (Screw connection) |
---|---|
18 V DC ... 30 V DC (as an alternative or redundant, via backplane bus contact and system current supply) | |
Typical current consumption | < 100 mA (24 V DC) |
Protective circuit | Protection against polarity reversal |
Connection method | Plug-in screw terminal block (COMBICON), redundancy possible |
Conductor cross section flexible max. | 2.50 mm² |
Conductor cross section flexible min. | 0.20 mm² |
Conductor cross section solid max. | 2.50 mm² |
Conductor cross section solid min. | 0.20 mm² |
Max. AWG conductor cross section, flexible | 14 |
Min. AWG conductor cross section, flexible | 24 |
Conductor cross section AWG max. | 14 |
Conductor cross section AWG min. | 24 |
Interface 1 | Ethernet interface, 10/100BASE-T(X) in acc. with IEEE 802.3u |
---|---|
Connection method | RJ45 socket, shielded |
Transmission medium | Copper |
Transmission length | 100 m (twisted pair, shielded) |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 14 |
Auto-negotiation modes | Auto |
Link through | Link fault pass through |
Basic functions | Store-and-forward media converter |
MDI-/MDI-X switchover | Auto-MDI(X) |
Signal LEDs | Activity, link status, 10/100 Mbps |
Transmit capacity, minimum | ≥ -23.5 dBm ((50/125 µm) dynamic in link mode (average)) |
---|---|
≥ -20 dBm ((62,5/125 µm) dynamic in link mode (average)) | |
Transmit capacity, maximum | ≤ -14 dBm ((50/125 µm) dynamic in link mode (average)) |
≤ -14 dBm ((62,5/125 µm) dynamic in link mode (average)) | |
Minimum receiver sensitivity | -31 dBm (dynamic in link mode (average)) |
Overrange receiver | -14 dBm (dynamic in link mode (average)) |
Wavelength | 1300 nm |
Transmission length incl. 3 dB system reserve | 6.4 km (with F-G 50/125 0,7 dB/km F 1000) |
2.8 km (with F-G 50/125 1,6 dB/km F 800) | |
10 km (with F-G 62,5/125 0,7 dB/km F 1000) | |
3 km (with F-G 62.5/125 2.6 dB/km F 600) | |
2 km (with 2GK200/230 GI-HCS) | |
Transmission medium | Multi-mode fiberglass |
GI-HCS fiber | |
Connection method | SC duplex |
Title: | Size: | Type: |
---|---|---|
PHOENIX CONTACT-2902853-FL MC EF 1300 MM SC | 191 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.