UKK 5-MTKD-P/P 2800017 PHOENIX CONTACT Feed-through terminal block View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

UKK 5-MTKD-P/P 2800017 PHOENIX CONTACT Feed-through terminal block

UKK 5-MTKD-P/P

2800017

PHOENIX_CONTACT

50

Feed-through terminal block

Feed-in terminal, with threaded sockets for test sockets to accommodate test pins, nominal voltage: 400 V, nominal current: 26 A, 1st floor, connection type: Screw connection, Sizing section: 4 mm², cross-section: 0.2 mm² - 4 mm².2. Floor, connection type: Screw connection, Sizing cross-section: 4 mm², cross-section: 0.25 mm² - 4 mm², Mounting: NS 35/7.5, NS 35/15, NS 32, color: gray

Feed-through terminal block, With test socket screws for insertion of test plugs, nom. voltage: 400 V, nominal current: 26 A, 1 level, connection method: Screw connection, Rated cross section: 4 mm2, cross section: 0.2 mm2 - 4 mm2, 2nd level, connection method: Screw connection, Rated cross section: 4 mm2, cross section: 0.25 mm2 - 4 mm2, mounting: NS 35/7,5, NS 35/15, NS 32, color: gray

More details


Modular TBs

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Often bought together

Best sellers

More info



Technical data

Product properties
Product typeFeed-through terminal block
Number of connections4
Number of rows2
Data management status
Article revision06
Insulation characteristics
Overvoltage categoryIII
Degree of pollution3

Electrical properties
Rated surge voltage6 kV
Maximum power dissipation for nominal condition1.02 W

Connection data
Number of connections per level2
Nominal cross section4 mm²
1 level
Screw threadM3
Tightening torque0.6 ... 0.8 Nm
Stripping length8 mm
Internal cylindrical gageA3
Connection in acc. with standardIEC 60947-7-1
Conductor cross section rigid0.2 mm² ... 4 mm²
Cross section AWG24 ... 12 (converted acc. to IEC)
Conductor cross section flexible0.2 mm² ... 4 mm²
Conductor cross section, flexible [AWG]24 ... 12 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)0.25 mm² ... 4 mm²
Flexible conductor cross section (ferrule with plastic sleeve)0.25 mm² ... 1.5 mm²
2 conductors with same cross section, solid0.2 mm² ... 1.5 mm²
2 conductors with same cross section, flexible0.2 mm² ... 1.5 mm²
2 conductors with same cross section, flexible, with ferrule without plastic sleeve0.25 mm² ... 1.5 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve0.5 mm² ... 1.5 mm²
Nominal current26 A
Maximum load current26 A (with 4 mm² conductor cross section)
Nominal voltage400 V
Nominal cross section4 mm²
2nd level
Screw threadM3
Internal cylindrical gageA4
Connection in acc. with standardIEC 60947-7-1
Conductor cross section rigid0.25 mm² ... 4 mm²
Cross section AWG24 ... 12 (converted acc. to IEC)
Conductor cross section flexible0.25 mm² ... 4 mm²
Conductor cross-section flexible (ferrule without plastic sleeve)0.25 mm² ... 4 mm²
Flexible conductor cross section (ferrule with plastic sleeve)0.25 mm² ... 2.5 mm²
2 conductors with same cross section, solid0.2 mm² ... 1.5 mm²
2 conductors with same cross section, flexible0.2 mm² ... 1.5 mm²
2 conductors with same cross section, flexible, with ferrule without plastic sleeve0.25 mm² ... 1.5 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve0.5 mm² ... 1.5 mm²
Nominal current12 A
Maximum load current12 A (with 4 mm² conductor cross section)
Nominal voltage400 V
Nominal cross section4 mm²

Dimensions
Width6.1 mm

Material specifications
Colorgray (RAL 7042)
Flammability rating according to UL 94V2
Insulating material groupI
Insulating materialPA

Mechanical properties
Mechanical data
Open side panelNo

Environmental and real-life conditions
Ambient conditions
Ambient temperature (operation)-60 °C ... 105 °C (max. short-term operating temperature RTI Elec.)
Ambient temperature (storage/transport)-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Ambient temperature (assembly)-5 °C ... 70 °C
Ambient temperature (actuation)-5 °C ... 70 °C
Permissible humidity (storage/transport)30 % ... 70 %

Standards and regulations
Connection in acc. with standardIEC 60947-7-1
IEC 60947-7-1

Mounting
Mounting typeNS 35/7,5
NS 35/15
NS 32

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.