STTBS 2,5 3038464 PHOENIX CONTACT Double-level spring-cage terminal block View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

STTBS 2,5 3038464 PHOENIX CONTACT Double-level spring-cage terminal block

STTBS 2,5

3038464

PHOENIX_CONTACT

Double-level spring-cage terminal block

Double-deck spring terminal block, nominal voltage: 500 V, nominal current: 22 A, connection type: Spring connection, 1st and 2nd floor, Sizing cross-section: 2.5 mm², cross-section: 0.08 mm² - 4 mm², mounting class: NS 35/7.5, NS 35/15, color: gray

Double-level spring-cage terminal block, nom. voltage: 500 V, nominal current: 22 A, connection method: Spring-cage connection, 1st and 2nd level, Rated cross section: 2.5 mm2, cross section: 0.08 mm2 - 4 mm2, mounting type: NS 35/7,5, NS 35/15, color: gray

More details


Terminal blocks > Feed-through terminal block

Modular TBs

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Often bought together

Best sellers

More info



Technical data

Product properties
Product typeMulti-level terminal block
Number of connections4
Number of rows2
Potentials2
Data management status
Article revision08
Insulation characteristics
Overvoltage categoryIII
Degree of pollution3

Electrical properties
Rated surge voltage6 kV
Maximum power dissipation for nominal condition0.77 W

Connection data
Number of connections per level2
Nominal cross section2.5 mm²
1st and 2nd level
Stripping length8 mm ... 10 mm
Internal cylindrical gageA3
Connection in acc. with standardIEC 60947-7-1
Conductor cross section rigid0.08 mm² ... 4 mm²
Cross section AWG28 ... 12 (converted acc. to IEC)
Conductor cross section flexible0.08 mm² ... 2.5 mm²
Conductor cross section, flexible [AWG]28 ... 14 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)0.14 mm² ... 2.5 mm²
Flexible conductor cross section (ferrule with plastic sleeve)0.14 mm² ... 2.5 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve0.5 mm²
Nominal current22 A
Maximum load current26 A (with 4 mm² conductor cross section)
Nominal voltage500 V
Nominal cross section2.5 mm²

Ex data
Rated data (ATEX/IECEx)
Identification II 2 G  Ex eb IIC Gb
Operating temperature range-60 °C ... 110 °C
Ex-certified accessories3038503 D-STTBS 2,5
1204517 SZF 1-0,6X3,5
3022276 CLIPFIX 35-5
3022218 CLIPFIX 35
List of bridgesPlug-in bridge / FBS 2-5 / 3030161
Plug-in bridge / FBS 3-5 / 3030174
Plug-in bridge / FBS 4-5 / 3030187
Plug-in bridge / FBS 5-5 / 3030190
Plug-in bridge / FBS 10-5 / 3030213
Plug-in bridge / FBS 20-5 / 3030226
Plug-in bridge / FBS 50-5 / 3038930
Bridge data19 A / 2.5 mm²
Ex temperature increase40 K (19.5 A / 2.5 mm²)
Rated voltage440 V
for bridging with bridge440 V
- At bridging between non-adjacent terminal blocks352 V
- At cut-to-length bridging220 V
- At cut-to-length bridging with cover220 V
Rated insulation voltage400 V
output(Permanent)
Ex level General
Rated current19.5 A
Maximum load current23.5 A
Ex connection data General
Nominal cross section2.5 mm²
Rated cross section AWG14
Connection capacity rigid0.08 mm² ... 4 mm²
Connection capacity AWG28 ... 12
Connection capacity flexible0.08 mm² ... 2.5 mm²
Connection capacity AWG28 ... 14
output(Permanent)
Ex level Level 1
Contact resistance1.25 mΩ
output(Permanent)
Ex level Level 2
Contact resistance0.83 mΩ

Dimensions
Width5.2 mm
End cover width2.2 mm
Height78 mm
Depth on NS 35/7,555 mm
Depth on NS 35/1562.5 mm

Material specifications
Colorgray (RAL 7042)
Flammability rating according to UL 94V0
Insulating material groupI
Insulating materialPA
Static insulating material application in cold-60 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))125 °C
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3
Calorimetric heat release NFPA 130 (ASTM E 1354)27,5 MJ/kg
Surface flammability NFPA 130 (ASTM E 162)passed
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Smoke gas toxicity NFPA 130 (SMP 800C)passed

Electrical tests
Surge voltage test
Test voltage setpoint7.3 kV
ResultTest passed
Short-time withstand current 2.5 mm²0.3 kA
Short-time withstand current 4 mm²0.48 kA
ResultTest passed
Power-frequency withstand voltage
Test voltage setpoint1.89 kV
ResultTest passed

Mechanical properties
Mechanical data
Open side panelYes

Mechanical tests
Mechanical strength
ResultTest passed
Attachment on the carrier
DIN rail/fixing supportNS 35
Test force setpoint1 N
ResultTest passed
Test for conductor damage and slackening
Rotation speed10 rpm
Revolutions135
Conductor cross section/weight0.08 mm² / 0.1 kg
2.5 mm² / 0.7 kg
4 mm² / 0.9 kg
ResultTest passed

Environmental and real-life conditions
Aging
Temperature cycles192
ResultTest passed
Needle-flame test
Time of exposure30 s
ResultTest passed
Oscillation/broadband noise
SpecificationDIN EN 50155 (VDE 0115-200):2008-03
SpectrumService life test category 2, bogie-mounted
Frequencyf1= 5 Hz to f2= 250 Hz
ASD level6.12 (m/s²)²/Hz
Acceleration3.12g
Test duration per axis5 h
Test directionsX-, Y- and Z-axis
ResultTest passed
Shocks
SpecificationDIN EN 50155 (VDE 0115-200):2008-03
Pulse shapeHalf-sine
Acceleration30g
Shock duration18 ms
Number of shocks per direction3
Test directionsX-, Y- and Z-axis (pos. and neg.)
ResultTest passed
Ambient conditions
Ambient temperature (operation)-60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Ambient temperature (storage/transport)-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Ambient temperature (assembly)-5 °C ... 70 °C
Ambient temperature (actuation)-5 °C ... 70 °C
Permissible humidity (operation)20 % ... 90 %
Permissible humidity (storage/transport)30 % ... 70 %

Standards and regulations
Connection in acc. with standardIEC 60947-7-1

Mounting
Mounting typeNS 35/7,5
NS 35/15

ETIM for 3038464 Terminal blocks (EC000897)
Feature Name Feature Value
Connectable conductor cross section fine-strand without cable end sleeve (EF007341) 0.08 mm²
Connectable conductor cross section fine-strand with cable end sleeve (EF007339) 0.14 mm²
Connectable conductor cross section solid-core (EF007337) 0.08 mm²
Rated current In (EF008250) 22 A
Rated voltage (EF000228) 500 V
Type of electrical connection 1 (EF002526) Spring clamp connection
Type of electrical connection 2 (EF002527) Spring clamp connection
Number of levels (EF002659) 2
Number of clamp positions per level (EF002660) 2
Suitable for conductor material (EF012572) Aluminium/copper
Mounting method (EF000003) DIN rail (top hat rail) 35 mm
Material insulation body (EF007543) Other
Inflammability class of insulation material according to UL94 (EF002521) V0
Width (EF000008) 5.2 mm
Height (EF000040) 78 mm
Depth (EF000049) 55 mm
Closing plate required (EF002525) Yes
Colour (EF000007) Grey
Internally connected stages (EF002661) No

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.