Device coupler in Zone 1 environment for FOUNDATION Fieldbus and PROFIBUS PA with terminal connections for eight branch outlets for fieldbus terminal equipment.

More details


PLC's > Fieldbus, decentr. periphery - power supply/segment module

Safety

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total: $2,822.99
Unit price: $2,822.99
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Best sellers

More info



Key Commercial Data

Orderkey2316311
Packing unit1 pc
Catalog pagePage 514 (C-6-2017)
GTIN4055626306803
Weight per Piece (excluding packing)1,190.000 g
Custom tariff number85389099
Country of originUS (United States)

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Dimensions

Dimensional drawing
Width279 mm
Height142 mm
Depth66 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 80 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)95 % (non-condensing)
Degree of protectionIP20
IP20, IP30 over trunk connections

General

Mounting positionOn horizontal and vertical DIN rail NS 35 in acc. with EN 60715
Net weight1190 g
Degree of pollution2
Overvoltage categoryII
ConformanceEMC 2014/30/EU
ATEX 2014/34/EU
Fieldbus FoundationFF-846

Power supply

Supply voltage range16 V DC ... 32 V DC (input on trunk line side)
Max. current consumption35 mA (trunk, no load)
350 mA (maximum trunk current)
Conductor cross section flexible max.0.20 mm²
Conductor cross section flexible min.2.50 mm²
Conductor cross section solid max.0.20 mm²
Conductor cross section solid min.2.50 mm²
Max. AWG conductor cross section, flexible12
Min. AWG conductor cross section, flexible24
Conductor cross section AWG max.12
Conductor cross section AWG min.24

Serial interface

Interface 1Foundation Fieldbus and PROFIBUS PA Segment
No. of ports8
Connection methodPluggable COMBICON screw connection for each spur
Termination resistorIntegrated termination, activated with bridge located in correct terminals
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Output nominal voltage≤ 14 V (each spur)
Output current35 mA (per spur)
Inductance Li0 µH
Max. output voltage Uo16.7 V

Safety data

Input voltage Ui32 V
Max. output voltage Uo16.7 V
Max. output current Io250 mA
Max. output power Po1.05 W
GroupIIC
Max. external capacity Co0.39 µF
GroupIIB
Max. external capacity Co2.33 µF
GroupIIC
Max. external inductivity Lo0.56 mH
GroupIIB
Max. external inductivity Lo2.27 mH
ATEXDEMKO 16ATEX 1689X
II 2(1) G Ex eb ib mb [ia Ga] IIC T4 Gb
II (1D) [Ex ia Da] IIIC
FISCO power supply (spur)
IECExIECEx UL 16.0114X
Ex eb ib mb [ia Ga] IIC T4 Gb
[Ex ia Da] IIIC
FISCO power supply (spur)
Safety-related maximum voltage Um253 V

Standards and Regulations

Type of testCorrosive resistance in acc. to ANSI-ISA 71.04-1985 - Severity level G3
DesignationStandards/regulations
Standards/regulationsRing wave noise immunidty in acc. with IEC 61000-4-12
DesignationStandards/regulations
Standards/regulationsDry heat in acc. with IEC 61131-2
DesignationStandards/regulations
Standards/regulationsDamp heat in acc. with IEC 61131-2
DesignationStandards/regulations
Standards/regulationsShock and vibration in acc. with EN 61131-2 and EN 50178
IEC 61158-2
Flammability rating according to UL 94V0
Shock15g for 11 ms
Vibration (operation)2g, 10 Hz ... 150 Hz
ConformanceEMC 2014/30/EU
ATEX 2014/34/EU
Fieldbus FoundationFF-846
GroupIIC
IIB
IIC
IIB
ATEXDEMKO 16ATEX 1689X
II 2(1) G Ex eb ib mb [ia Ga] IIC T4 Gb
II (1D) [Ex ia Da] IIIC
FISCO power supply (spur)
IECExIECEx UL 16.0114X
Ex eb ib mb [ia Ga] IIC T4 Gb
[Ex ia Da] IIIC
FISCO power supply (spur)
UL, USA/CanadaInstall in Class I, Div. 2, Groups A, B, C, D
Entity/FISCO spur to: Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III; Group IIIC
Class I, Zone 1 AEx eb ib mb [ia Ga] IIC T4 Gb
[AEx ia Da] IIIC
FISCO power supply (spur)
Ex eb ib mb [ia Ga] IIC T4 Gb
[Ex ia Da] IIIC
FISCO power supply (spur)

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications


ETIM for 2316311 PLC's (EC001600)
Feature Name Feature Value
Supply voltage DC (EF007534) 16 V
Voltage type (supply voltage) (EF002991) DC
Number of HW-interfaces industrial Ethernet (EF003020) 0
Number of interfaces PROFINET (EF006932) 0
Number of HW-interfaces RS-232 (EF003021) 0
Number of HW-interfaces RS-422 (EF003022) 0
Number of HW-interfaces RS-485 (EF003023) 8
Number of HW-interfaces serial TTY (EF003024) 0
Number of HW-interfaces parallel (EF003026) 0
Number of HW-interfaces wireless (EF006933) 0
Number of HW-interfaces USB (EF003025) 0
Number of HW-interfaces other (EF003027) 0
With optical interface (EF003028) No
System accessory (EF004118) Yes
Degree of protection (IP) (EF005474) IP20
Type of electric connection (EF003961) Other
With potential separation (EF003272) No
With power supply module (EF003993) No
Suitable as segment module (EF004104) Yes
Remote module (EF006653) No
Fieldbus connection over separate bus coupler possible (EF004002) Yes
Bus diagnosis possible (EF003989) No
Suitable for rail mounting (EF003972) Yes
Wall mounting/direct mounting (EF007020) No
Front built-in possible (EF007016) No
Rack-assembly possible (EF007018) No
Suitable for safety functions (EF001597) No
SIL according to IEC 61508 (EF009889) None
Performance level according to EN ISO 13849-1 (EF007399) None
Appendant operation agent (Ex ia) (EF004141) No
Appendant operation agent (Ex ib) (EF004142) No
Explosion safety category for gas (EF003997) None
Explosion safety category for dust (EF003998) None

Datasheet - PDF

Title: Size: Type:
PDF CATALOGUE AUTOMATION PHOENIX EN.pdf 35 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.