The output loop-fed head transmitter transmits up to two sensor signals from RTD and CT sensors, as well as resistance and voltage transmitters via HART or 4 ... 20 mA, configurable. SIL2/3

More details


INTERFACE Components (IF)

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Key Commercial Data

Orderkey2908742
Packing unit1 pc
NoteMade to Order (non-returnable)
Catalog pagePage 187 (C-5-2017)
GTIN4055626347783
Weight per Piece (excluding packing)186.600 g
Custom tariff number85437090
Country of originDE (Germany)

Ambient conditions

Ambient temperature (operation)-40 °C ... 85 °C
-40 °C ... 70 °C (SIL active)
Ambient temperature (storage/transport)-50 °C ... 100 °C
Maximum altitude≤ 4000 m (Above sea level)

Input data

Sensor types (RTD) that can be usedPt, Ni, Cu sensors: 2, 3, 4-wire
Sensor types that can be used (TC)A, B, C, D, E, J, K, L, N, R, S, T, U
Linear resistance measuring range10 Ω ... 2000 Ω (Minimum measuring span: 10 Ω)

Output data

Configurable/programmableno
Current output signal4 mA ... 20 mA (HART)
20 mA ... 4 mA (HART)
Max. output current23 mA

Power supply

Supply voltage range11 V ... 42 V (Standard)
11 V ... 32 V (SIL active)
Max. current consumption≤ 23 mA

Connection data

Connection methodPush-in connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.16
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Stripping length10 mm

General

Overvoltage categoryII
Degree of pollution2
Assembly instructionsInstallation in connecting head B in accordance with DIN EN 50446
ConformanceCE-compliant
ATEX II 3G Ex nA IIC T6...T4 Gc
UL, USA/CanadaUL 61010 Recognized
FM approvalNI / Class I / Div. 1, 2 / Group ABCD T6/T5/T4
CSANI, Class I, Div. 2, Groups A, B, C, D

Standards and Regulations

ConformanceCE-compliant
ATEX II 3G Ex nA IIC T6...T4 Gc
UL, USA/CanadaUL 61010 Recognized
FM approvalNI / Class I / Div. 1, 2 / Group ABCD T6/T5/T4
CSANI, Class I, Div. 2, Groups A, B, C, D

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications


Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.