MACX MCR-EX-SL-TC-I-NC 2865586 PHOENIX CONTACT Ex-i temperature measuring transducer: Converts signals from .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

MACX MCR-EX-SL-TC-I-NC 2865586 PHOENIX CONTACT Ex-i temperature measuring transducer: Converts signals from ..

MACX MCR-EX-SL-TC-I-NC

2865586

PHOENIX_CONTACT

Available

Ship on today

Ex-i temperature measuring transducer: Converts signals from thermocouples installed in Ex areas and mV sources and transmits a 0/4-20 mA signal to a load in a safe area. Freely programmable, 3-way isolation

More details


Programmable Logic Controllers Plcs

INTERFACE Signal converters, switching devices, and power supply units - PHOENIX CONTACT

MSR Components for Ex areas - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+227,06 €
2+221,76 €
3+219,13 €
4+218,72 €
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Dimensions

Width12.5 mm
Height99 mm
Depth114.5 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 60 °C (Any mounting position)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Maximum altitude≤ 2000 m
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Noise immunityEN 61000-6-2 When being exposed to interference, there may be minimal deviations.
Degree of protectionIP20

Input data

InputIntrinsically safe
Sensor types that can be used (TC)E, J, K, N as per IEC / EN 60584, L as per DIN 43760
Temperature measuring range-250 °C ... 1372 °C (Range depending on the sensor type)
Input signal range-20 mV ... 70 mV
Measuring range spanMin. 50 K for thermocouples, 3 mV for mV sources

Output data

Signal outputCurrent output
Current output signal0 mA ... 20 mA
4 mA ... 20 mA
Load/output load current output≤ 500 Ω
Output ripple (current)< 50 µAPP
Behavior in the event of a sensor errorAs per NE 43 or can be freely defined

Power supply

Nominal supply voltage24 V DC
Supply voltage range19.2 V DC ... 30 V DC (24 V DC (-20% ... +25%))
Max. current consumption< 40 mA (24 V DC)
Power consumption< 1 W

Connection data

Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Stripping length7 mm
Screw threadM3
Connection methodScrew connection
Tightening torque, min0.5 Nm
Tightening torque max0.6 Nm

General

No. of channels1
Temperature coefficient, typical0.01 %/K
Typical cold point errors± 1 K
Step response (0–99%)typ. 700 ms
≤ 1100 ms
Alignment zero± 5 %
Alignment span± 5 %
Status displayGreen LED (supply voltage, PWR)
Red LED, flashing (line, sensor error, ERR)
Red LED (module error, ERR)
Flammability rating according to UL 94V0
Pollution degree2
Overvoltage categoryII
Emitted interferenceEN 61000-6-4
Housing materialPA 66-FR
Colorgreen
DesignationInput/output/power supply
Electrical isolation300 Vrms (Rated insulation voltage (overvoltage category II; pollution degree 2, safe isolation as per EN 61010-1))
2.5 kV (50 Hz, 1 min., test voltage)
DesignationInput/output
Electrical isolation375 V (Peak value in accordance with EN 60079-11)
DesignationInput/power supply
Electrical isolation375 V (Peak value in accordance with EN 60079-11)
ConformanceCE-compliant, additionally EN 61326
ATEXEx II (1) G [Ex ia Ga] IIC/IIB
Ex II (1) D [Ex ia Da] IIIC
Ex II 3(1) G Ex nA ic [ia Ga] IIC T4 Gc X
IECEx[Ex ia Ga] IIC/IIB
[Ex ia Da] IIIC
Ex nA ic [ia Ga] IIC T4 Gc
UL, USA / CanadaClass I Div 2; IS for Class I, II, III Div 1

Safety characteristic data

Safety Integrity Level (SIL)2

Safety data

Max. output voltage Uo6 V
Max. output current Io4.7 mA
Max. output power Po7 mW
GroupIIC
Max. external inductivity Lo100 mH
Max. external capacity Co1.5 µF
GroupIIC
Max. external inductivity Lo10 mH
Max. external capacity Co1.9 µF
GroupIIC
Max. external inductivity Lo1 mH
Max. external capacity Co2.7 µF
GroupIIB
Max. external inductivity Lo100 mH
Max. external capacity Co7 µF
GroupIIB
Max. external inductivity Lo10 mH
Max. external capacity Co9.4 µF
GroupIIB
Max. external inductivity Lo1 mH
Max. external capacity Co15 µF
Safety-related maximum voltage Um253 V AC (125 V DC)

EMC data

DesignationElectromagnetic RF field
Standards/regulationsEN 61000-4-3
Typical deviation from the measuring range final value3 %
DesignationFast transients (burst)
Standards/regulationsEN 61000-4-4
Typical deviation from the measuring range final value3 %
DesignationConducted interferences
Standards/regulationsEN 61000-4-6
Typical deviation from the measuring range final value3 %