AC charging controller
The EV Charge Control is used to charge electric vehicles in a three-phase alternating current network in accordance with IEC 61851-1 Mode 3. All the control functions required for this are integrated. Additional functions are available for different charging applications.
EV charge control is used to charge electrical vehicles on the 3-phase AC mains power supply according to IEC 61851-1 Mode 3. All necessary control functions are integrated. Additional functions are available for various charging applications.
E-Mobility
Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Product type | AC charging controller |
| Product family | CHARX control advanced |
| Application | AC charging controller for commercial applications (EU) |
| Operating mode | Stand-Alone |
| Client | |
| Charging standard | Type 2 |
| Charging mode | Mode 3, Case B + C |
| Data management status | |
| Article revision | 15 |
| Charging controllers | |
| Number of charging points | 1 |
| Type of charging current | AC 3-phase |
| Current consumption | < 1 W |
| Locking release in the event of mains failure | With EM-EV-CLR-12V locking release module (Item No. 2903246) as an option |
| Supply | |
| Supply voltage | 230 V |
| Supply voltage range | 110 V AC ... 240 V AC (nominal voltage range) |
| 95 V AC ... 264 V AC | |
| Max. current consumption | 40 mA |
| Nominal power consumption | < 1 W (No-load) |
| Frequency range | 45 Hz ... 65 Hz |
| Digital | |
| Number of digital inputs | 4 |
| Frequency range | 50 Hz ... 60 Hz |
| Nominal current IN | ≤ 8 mA |
| Nominal input voltage UN | 24 V |
| Input voltage range U1 | -3 V ... 5 V (Off) |
| Input voltage range U2 | 15 V ... 30 V (On) |
| Digital | |
| Output name | 4 digital outputs |
| Connection technology | Screw connection |
| Maximum output voltage | 30 V |
| Maximum output current | 0.2 A (Total current for all outputs; internally supplied) |
| Maximum output current per channel | 0.6 A (Per output; externally supplied) |
| Digital | |
| Output name | Relay output V1.2 |
| Maximum switching voltage | 250 V AC |
| Max. switching current | 2 A |
| Switching | |
| Output name | Relay output C1.2 |
| Minimum switching capacity | 1500 VA |
| Maximum switching voltage | 250 V AC (External supply) |
| Max. switching current | 2 A |
| Switching | |
| Output name | Relay output R1.3and R2.4 |
| Minimum switching capacity | 180 VA |
| Maximum switching voltage | 30 V AC/DC (External supply) |
| Max. switching current | 2 A |
| Conductor connection | |
| Connection method | Screw connection |
| Conductor cross section rigid | 0.2 mm² ... 4 mm² |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section AWG | 24 ... 12 |
| Interface | Ethernet (1x) |
| RS-485 | |
| Interface | RS-485 2-wire |
| Bus system | RS-485 |
| Connection method | Screw connection |
| Number of interfaces | 1 |
| Number of supported devices | 1 |
| Transmission speed | 9.6 kbps (Standard) |
| Transmission speed range | 2.4 kbps ... 19.2 kbps (adjustable) |
| Data flow control/protocols | Modbus/RTU (slave) |
| Ethernet | |
| Interface | Ethernet |
| Bus system | RJ45 |
| Connection method | RJ45 jack |
| Number of interfaces | 1 |
| Serial transmission speed | 10/100 Mbps |
| Transmission length | max. 100 m (with shielded, twisted-pair data cable) |
| Protocols supported | Modbus/TCP |
| Ambient conditions | |
| Degree of protection | IP20 |
| Ambient temperature (operation) | -25 °C ... 60 °C |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Permissible humidity (operation) | 30 % ... 95 % (non-condensing) |
| Conformity/Approvals | |
| Conformance | CE-compliant |
| Electromagnetic compatibility | Conformance with EMC Directive 2004/108/EC |
| Low Voltage Directive | Conformance with LV directive 2006/95/EC |
| Noise immunity | EN 61000-6-2 |
| Housing | DIN 43880 |
| Noise emission | EN 61000-6-3 |
| Standards | |
| Standards/regulations | IEC 61851-1 |
| Mounting type | DIN rail mounting |
| Mounting position | any |
| Feature Name | Feature Value |
|---|---|
| Emergency release at power failure (EF009316) | Yes |
| Max. number of addressable charging points (EF009156) | 1 |
| With communication interface (EF006609) | Yes |
| Width (EF000008) | 71.6 mm |
| Height (EF000040) | 90 mm |
| Depth (EF000049) | 61 mm |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG PHOENIX CHARGING TECHNOLOGY ELECTROMOBILITY EN.pdf | 6 Mbytes |
|
| PHOENIX CONTACT-2902802-EM-CP-PP-ETH | 196 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.