PHOENIX CONTACT  IL EIP BK DI8 DO4 2TX-PAC 2897758 - Image 1

Images are for illustrative purposes only. Please refer to data sheet for details.

IL EIP BK DI8 DO4 2TX-PAC 2897758 PHOENIX CONTACT Bus coupler

Reference: IL EIP BK DI8 DO4 2TX-PAC

Code: 2897758

Manufacturer: PHOENIX CONTACT

Description:

Bus coupler
Inline, Bus coupler, EtherNet/IP™, RJ45 female, Digital inputs: 8, 24 VDC, connection technology: 3 conductors, Digital outputs:4, 24 VDC, 500 mA, connection technology:3 conductors, transmission speed on the local bus:500 kBit/s / 2 MBit/s, protection index: IP20, including Inline connectors and marking fields
Inline, Bus coupler, EtherNet/IP™, RJ45 female, Digital inputs: 8, 24 V DC, connection technology: 3 conductors, Digital outputs: 4, 24 V DC, 500 mA, connection technology: 3 conductors, transmission speed on the local bus: 500 kBit/s / 2 MBit/s, protection index: IP20, including Inline connectors and marking fields

Categories:

  • PLC's > Fieldbus, decentr. periphery - communication module
  • PHOENIX CONTACT > I/O

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX CONTACT

  • More Info
  • ETIM
  • PDF
  • Reviews
Guarantee, repair and return.

Unit Price: 522,48 €

This price is per unit and is the net value (not including taxes if applicable).

Calculate price by quantity

QuantityPrice
Stock delivery monday. 3 units.

More units, standard lead time: 2-3 weeks.

  • These delivery times are an estimate any may vary when the item order has been processed.

LAST VIEWED

MORE INFO

Key Commercial Data

Orderkey2897758
Packing unit1 pc
Catalog pagePage 126 (C-6-2017)
GTIN4046356157926
Weight per Piece (excluding packing)320.000 g
Custom tariff number85176200
Country of originDE (Germany)

Note

Utilization restriction1

Dimensions

Dimensional drawing
Width80 mm
Height119.8 mm
Depth71.5 mm
Note on dimensionsSpecfications with connectors

Ambient conditions

Ambient temperature (operation)-25 °C ... 60 °C
Ambient temperature (storage/transport)-25 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)10 % ... 95 % (non-condensing)
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protectionIP20

General

Mounting typeDIN rail
Net weight320 g
Note on weight specificationswith connectors
Diagnostics messagesShort-circuit / overload of the digital outputs Yes
Sensor supply failure Yes
Failure of the actuator supply Yes

Interfaces

DesignationEtherNet/IP™
No. of channels2
Connection methodRJ45 socket
Note on the connection methodAuto negotiation and autocrossing
Transmission speed10/100 Mbps (half or full duplex (automatic detection))
Transmission physicsEthernet in RJ45 twisted pair
Permissible conductor cross section0.14 mm² ... 0.22 mm² (twisted pair)
DesignationInline local bus
Connection methodInline data jumper
Transmission speed500 kbps / 2 Mbps (automatic detection, no combined system)

System limits of the bus coupler

DesignationSystem limits of the bus coupler
Amount of process datamax. 512 Byte (per station)
Number of supported devicesmax. 63 (per station)
Number of local bus devices that can be connectedmax. 61 (on board I/Os are two devices)
Number of devices with parameter channelmax. 8
Number of supported branch terminals with remote bus branch0

Inline potentials

DesignationBus coupler supply UBC; Communications power UL(7.5 V) and the analog supply UANA(24 V) are generated from the bus coupler supply.
Supply voltage24 V DC (via Inline connector)
Supply voltage range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current consumption80 mA (without connected I/O terminal blocks)
max. 0.98 A
DesignationCommunications power (UL)
Supply voltage7.5 V DC
Power supply unitmax. 0.8 A DC
DesignationSupply of analog modules (UANA)
Supply voltage24 V DC
Supply voltage range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Power supply unitmax. 0.5 A DC
DesignationMain circuit supply (UM)
Supply voltage24 V DC (via Inline connector)
Supply voltage range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Power supply unitmax. 8 A DC (sum of UM+ US)
Current consumption3 mA (without sensors)
max. 8 A DC
DesignationSegment circuit supply (US)
Supply voltage24 V DC (via Inline connector)
Supply voltage range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Power supply unitmax. 8 A DC (sum of UM+ US)
Current consumptionmax. 8 A DC
Type of protectionShort-circuit protection of the communications power
Short-circuit protection of the analog supply
Power consumptiontyp. 3 W (entire device)
Current consumption6 mA (Without connected peripherals)

Digital inputs

Input nameDigital inputs
Description of the inputEN 61131-2 type 1
Connection methodInline connector
Connection technology3-wire
Number of inputs8
Typical response timeapprox. 500 µs
Type of protectionReverse polarity protection
Input voltage24 V DC
Input voltage range "0" signal-30 V DC ... 5 V DC
Input voltage range "1" signal15 V DC ... 30 V DC
Nominal input current at UINtyp. 3 mA
Typical input current per channeltyp. 3 mA
Delay at signal change from 0 to 11.2 ms
Delay at signal change from 1 to 01.2 ms

Digital outputs

Output nameDigital outputs
Connection methodInline connector
Connection technology3-wire
Number of outputs4
Type of protectionShort-circuit and overload protection
Output voltage24 V DC -1 V (At nominal current)
Nominal output voltage24 V DC
Maximum output current per channel500 mA
Maximum output current per module / terminal block2 A
Maximum output current per module2 A
Nominal load, inductive12 VA (1.2 H, 48 Ω)
Nominal load, lamp12 W
Nominal load, ohmic12 W

Standards and Regulations

Mechanical testsVibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
Shock in acc. with EN 60068-2-27/IEC 60068-2-27 Operation: 25g, 11 ms duration, semi-sinusoidal shock impulse
Connection in acc. with standardCUL
Protection classIII, IEC 61140, EN 61140, VDE 0140-1

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications

ETIM for 2897758 PLC's (EC001604)

Feature nameSupply voltage DC (EF007534)
Feature value19.2 V
Feature nameVoltage type (supply voltage) (EF002991)
Feature valueDC
Feature nameSupporting protocol for EtherCAT (EF017564)
Feature valueNo
Feature nameSupporting protocol for EtherNet/IP (EF007521)
Feature valueYes
Feature nameRadio standard Bluetooth (EF007178)
Feature valueNo
Feature nameRadio standard WLAN 802.11 (EF007179)
Feature valueNo
Feature nameRadio standard GPRS (EF008523)
Feature valueNo
Feature nameIO link master (EF007298)
Feature valueNo
Feature nameSystem accessory (EF004118)
Feature valueYes
Feature nameDegree of protection (IP) (EF005474)
Feature valueIP20
Feature nameWith potential separation (EF003272)
Feature valueNo
Feature nameFieldbus connection over separate bus coupler possible (EF004002)
Feature valueYes
Feature nameSuitable for rail mounting (EF003972)
Feature valueYes
Feature nameWall mounting/direct mounting (EF007020)
Feature valueNo
Feature nameFront built-in possible (EF007016)
Feature valueNo
Feature nameRack-assembly possible (EF007018)
Feature valueNo
Feature nameSuitable for safety functions (EF001597)
Feature valueNo
Feature namePerformance level according to EN ISO 13849-1 (EF007399)
Feature valueNone
Feature nameAppendant operation agent (Ex ia) (EF004141)
Feature valueNo
Feature nameAppendant operation agent (Ex ib) (EF004142)
Feature valueNo
Feature nameExplosion safety category for gas (EF003997)
Feature valueNone
Feature nameExplosion safety category for dust (EF003998)
Feature valueNone
Feature nameWidth (EF000008)
Feature value80 mm
Feature nameHeight (EF000040)
Feature value120.55 mm
Feature nameDepth (EF000049)
Feature value71.24238 mm

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.