SAC-FSA/ 3,0-93G/R4AQ 1406449 PHOENIX CONTACT Bus system cable View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

SAC-FSA/ 3,0-93G/R4AQ 1406449 PHOENIX CONTACT Bus system cable

SAC-FSA/ 3,0-93G/R4AQ

1406449

PHOENIX_CONTACT

50

Bus system cable

Cable EtherCAT®assembled, shielded, star quads, flexible AWG 22 (7 wires), RAL 6018 (yellow-green), M12 connection female, A-coded, SPEEDCON, 4 pin to RJ45/IP20 male connector, length: 3 m

More details


Sensors > Sensor-actuator patch cord

Industrial Field Connectivity (IFC)

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Key Commercial Data

Orderkey1406449
Packing unit1 pc
Minimum order quantity50 pc
NoteMade to Order (non-returnable)
GTIN4046356767361
Weight per Piece (excluding packing)231.170 g
Custom tariff number85444290
Country of originPL (Poland)

Dimensions

Length of cable3 m

Ambient conditions

Degree of protectionIP20

General

Rated voltage48 V AC
60 V DC
Number of positions4
Degree of pollution3
Insertion/withdrawal cycles≥ 100

Material

Flammability rating according to UL 94V0

Standards and Regulations

Flammability rating according to UL 94V0

Cable

Cable typePROFINET PVC stranded CAT5
Cable type (abbreviation)93B
Cable abbreviation2YY(ST)CY
UL AWM style21694
Cable structure1x4xAWG22/7; SF/TQ
Conductor cross section4x 0.34 mm²
AWG signal line22
Conductor structure signal line7x 0.25 mm
Core diameter including insulation1.55 mm
Wire colorsWhite, yellow, blue, orange
Overall twistStar quad
ShieldingAluminum-coated foil, tinned copper braided shield
Optical shield covering85 %
External sheath, colorgreen RAL 6018
Outer sheath thicknessapprox. 0.9 mm
External cable diameter D6.5 mm ±0.2 mm
Minimum bending radius, fixed installation3 x D
Minimum bending radius, flexible installation7 x D
Cable weight67 kg/km
Outer sheath, materialPVC
Material, inner sheathPVC
Material conductor insulationPE
Conductor materialTin-plated Cu litz wires
Insulation resistance≥ 500 MΩ*km
Loop resistance≤ 120.00 Ω/km
Wave impedance100 Ω ±15 Ω (at 100 MHz)
Near end crosstalk attenuation (NEXT)80 dB (with 1 MHz)
76 dB (at 4 МHz)
70 dB (at 10 MHz)
65 dB (at 16 MHz)
63 dB (at 20 МHz)
60 dB (at 31.25 МHz)
55 dB (at 62.5 МHz)
50 dB (at 100 MHz)
Attenuation2.1 dB (with 1 MHz)
4 dB (at 4 МHz)
6.3 dB (at 10 MHz)
8 dB (at 16 MHz)
9 dB (at 20 МHz)
11.4 dB (at 31.25 МHz)
16.5 dB (at 62.5 МHz)
21.3 dB (at 100 MHz)
Signal speed0.66 c
Signal runtime5.3 ns/m
Coupling resistance≤ 20.00 mΩ/m (at 10 MHz)
Nominal voltage, cable600 V
Test voltage Core/Core2000 V (50 Hz, 1 min.)
Test voltage Core/Shield2000 V (50 Hz, 1 min.)
Flame resistanceaccording to UL 1685 (CSA FT 4)
Resistance to oilResistant to oil to a limited extent
Other resistanceUV resistant According to UL 1581, Section 1200
Ambient temperature (operation)-40 °C ... 70 °C (cable, fixed installation)
-40 °C ... 70 °C (cable, flexible installation)

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications


Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.