Product successfully added to your shopping cart
EEM-MA600
2901366
PHOENIX_CONTACT
1
Measuring instrument
INTERFACE Components (IF)
* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Orderkey | 2901366 |
---|---|
Packing unit | 1 pc |
Catalog page | Page 208 (C-5-2017) |
GTIN | 4046356584258 |
Weight per Piece (excluding packing) | 821.500 g |
Custom tariff number | 90303100 |
Country of origin | TN (Tunisia) |
Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
---|
Width | 96 mm |
---|---|
Height | 96 mm |
Depth | 82 mm |
Installation depth with extension module | 80 mm |
Installation depth without extension module | 60 mm |
Ambient temperature (operation) | -10 °C ... 55 °C (14 °F to 131 °F) |
---|---|
Ambient temperature (storage/transport) | -20 °C ... 85 °C (-4 °F ... 185 °F) |
Max. permissible relative humidity (operation) | ≤ 95 % |
Max. salt spray content | ≤ 2.5 % |
Measuring principle | True r.m.s. value measurement |
---|---|
Acquisition of harmonics | up to 63rd harmonic |
Measured value | AC sine (50/60 Hz) |
Input name | Voltage measuring input V1, V2, V3 |
Input voltage range | 18 V AC ... 700 V AC (Phase/Phase) |
11 V AC ... 404 V AC (Phase/neutral conductor) | |
Input voltage | 500 kV AC (Primary, via external voltage transducers) |
Secondary: 60, 100, 110, 115, 120, 173, 190 V AC | |
Precision | 0.2 % |
Input name | Current measurement I1, I2, I3 |
Input current range | via external transformers |
Input current | 9999 A (primary) |
1 A and 5 A, secondary | |
Current measuring range | 0 A ... 9999 A |
Overload capacity | 6 A (Permanent) |
Response threshold from measuring range nominal value | 10 mA |
Precision | 0.2 % |
Current overload | 10 x INfor 1 s |
Messbereich_Leistung | 0 MW ... 8000 MW |
0 Mvar ... 8000 Mvar | |
0 MVA ... 8000 MVA | |
Precision | 0.5 % |
Active energy (IEC 62053-22) | Class 0.5 S |
Reactive power (IEC 62053-23) | Class 2 |
Voltage input signal | Via function module |
Display | LCD display, backlighting |
---|---|
Measuring rate | approximately |
Supply voltage | 230 V AC |
Supply voltage range | 110 V AC ... 400 V AC ±10 % |
Nominal power consumption | 10 VA |
Power consumption | 20 VA (with max. number of extension modules) |
Mains type | 3-phase (3 or 4-wire), 2-phase (2-wire), and single-phase (1-wire) |
Color | black |
Conformance | CE-compliant |
Rated insulation voltage at mains voltage < 300 V AC (L/N) | III |
Rated insulation voltage at mains voltage > 300 V AC - 600 V AC (L/N) | II |
Test voltage | 3.5 kV AC (50 Hz, 1 min.) |
Conductor cross section flexible min. | 0.5 mm² |
---|---|
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section solid min. | 0.5 mm² |
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section AWG min. | 20 |
Conductor cross section AWG max. | 14 |
Connection method | COMBICON plug-in screw terminal block |
Stripping length | 6 mm |
Tightening torque | 0.4 Nm |
Note | Voltage and other connections |
Conductor cross section flexible min. | 0.5 mm² |
Conductor cross section flexible max. | 6 mm² |
Conductor cross section solid min. | 0.5 mm² |
Conductor cross section solid max. | 6 mm² |
Conductor cross section AWG min. | 20 |
Conductor cross section AWG max. | 8 |
Connection method | Screw connection |
Stripping length | 7 mm |
Note | Current connection |
Nominal supply voltage range | 110 V AC ... 240 V AC ±10 % |
---|---|
120 V DC ... 250 V DC ±10 % | |
Power consumption | 10 VA |
Operating mode | Indoor use |
Surge voltages | Transient overvoltage according to installation classes |
Overvoltage category | I, II, III |
Overvoltage category of the supply | Min. II |
Altitude | ≤ 2000 m |
Ambient temperature (operation) | 0 °C ... 40 °C |
Max. permissible relative humidity (operation) | 80 % (up to 31°C) |
50 % (at 40 °C) |
China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
---|---|
No hazardous substances above threshold values |
Title: | Size: | Type: |
---|---|---|
PDF CATALOG PHOENIX INTERFACE TECHNOLOGY AND SWITCHING DEVICES EN.pdf | 27 Mbytes | |
PHOENIX CONTACT-2901366-EEM-MA600 | 111 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.