EEM-MA600 2901366 PHOENIX CONTACT Measuring instrument View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

EEM-MA600 2901366 PHOENIX CONTACT Measuring instrument

EEM-MA600

2901366

PHOENIX_CONTACT

Measuring instrument

More details


INTERFACE Components (IF)

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

Go to successor article: EEM-MA770 2907945

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Key Commercial Data

Orderkey2901366
Packing unit1 pc
Catalog pagePage 208 (C-5-2017)
GTIN4046356584258
Weight per Piece (excluding packing)821.500 g
Custom tariff number90303100
Country of originTN (Tunisia)

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Dimensions

Width96 mm
Height96 mm
Depth82 mm
Installation depth with extension module80 mm
Installation depth without extension module60 mm

Ambient conditions

Ambient temperature (operation)-10 °C ... 55 °C (14 °F to 131 °F)
Ambient temperature (storage/transport)-20 °C ... 85 °C (-4 °F ... 185 °F)
Max. permissible relative humidity (operation)≤ 95 %
Max. salt spray content≤ 2.5 %

Input data

Measuring principleTrue r.m.s. value measurement
Acquisition of harmonicsup to 63rd harmonic
Measured valueAC sine (50/60 Hz)
Input nameVoltage measuring input V1, V2, V3
Input voltage range18 V AC ... 700 V AC (Phase/Phase)
11 V AC ... 404 V AC (Phase/neutral conductor)
Input voltage500 kV AC (Primary, via external voltage transducers)
Secondary: 60, 100, 110, 115, 120, 173, 190 V AC
Precision0.2 %
Input nameCurrent measurement I1, I2, I3
Input current rangevia external transformers
Input current9999 A (primary)
1 A and 5 A, secondary
Current measuring range0 A ... 9999 A
Overload capacity6 A (Permanent)
Response threshold from measuring range nominal value10 mA
Precision0.2 %
Current overload10 x INfor 1 s
Messbereich_Leistung0 MW ... 8000 MW
0 Mvar ... 8000 Mvar
0 MVA ... 8000 MVA
Precision0.5 %
Active energy (IEC 62053-22)Class 0.5 S
Reactive power (IEC 62053-23)Class 2
Voltage input signalVia function module

Output data

Output descriptionVia function module

Interfaces

Designationvia communication module

General

DisplayLCD display, backlighting
Measuring rateapproximately
Supply voltage230 V AC
Supply voltage range110 V AC ... 400 V AC ±10 %
Nominal power consumption10 VA
Power consumption20 VA (with max. number of extension modules)
Mains type3-phase (3 or 4-wire), 2-phase (2-wire), and single-phase (1-wire)
Colorblack
ConformanceCE-compliant
Rated insulation voltage at mains voltage < 300 V AC (L/N)III
Rated insulation voltage at mains voltage > 300 V AC - 600 V AC (L/N)II
Test voltage3.5 kV AC (50 Hz, 1 min.)

Connection data

Conductor cross section flexible min.0.5 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section solid min.0.5 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section AWG min.20
Conductor cross section AWG max.14
Connection methodCOMBICON plug-in screw terminal block
Stripping length6 mm
Tightening torque0.4 Nm
NoteVoltage and other connections
Conductor cross section flexible min.0.5 mm²
Conductor cross section flexible max.6 mm²
Conductor cross section solid min.0.5 mm²
Conductor cross section solid max.6 mm²
Conductor cross section AWG min.20
Conductor cross section AWG max.8
Connection methodScrew connection
Stripping length7 mm
NoteCurrent connection

UL data

Nominal supply voltage range110 V AC ... 240 V AC ±10 %
120 V DC ... 250 V DC ±10 %
Power consumption10 VA
Operating modeIndoor use
Surge voltagesTransient overvoltage according to installation classes
Overvoltage categoryI, II, III
Overvoltage category of the supplyMin. II
Altitude≤ 2000 m
Ambient temperature (operation)0 °C ... 40 °C
Max. permissible relative humidity (operation)80 % (up to 31°C)
50 % (at 40 °C)

Standards and Regulations

ConformanceCE-compliant
UL, USA/CanadaUL 61010-1
CSA-C22.2 No. 61010-1
cULus

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.