| Product type | Electronic motor manager |
| Operating mode | 100% operating factor |
| Number of phases | 3 |
| Mains type | 3-phase |
| Test voltage input/output | 2.5 kV |
| Supply | |
| Input name | Device supply |
| Nominal supply voltage | 24 V DC |
| Supply voltage range with reference to UVN | 0.8 ... 1.2 |
| Quiescent current | 80 mA AC |
| Current consumption | 80 mA |
| Protective circuit | Reverse polarity protection; Series polarity protection diode |
| Surge protection | |
| Operating voltage display | Green LED |
| Error indication | Red LED |
| Status display | LED (yellow) |
| Supply | |
| Input name | Supply voltage for 2 A digital outputs |
| Nominal supply voltage | 24 V DC ±20 % |
| Nominal input voltage UN | 24 V DC ±20 % |
| Typical input current at UN | 2 A |
| Control | |
| Input name | Control input right/left |
| Nominal input voltage UN | 24 V DC |
| Input voltage range in reference to UN | 0.8 ... 1.2 |
| 0.8 ... 1.2 | |
| Typical input current at UN | 7 mA |
| Current consumption | 7 mA |
| Reaction time in normal load operation | < 25 ms |
| Typical response time | < 25 ms |
| Typical turn-off time | < 25 ms |
| Reaction time in normal load operation | < 25 ms |
| Status display | LED yellow, forward running (R), LED yellow, reverse running (L) |
| Measurement | |
| Input name | Voltage measuring input V1, V2, V3 |
| Input voltage range | 110 V AC ... 550 V AC (conductor voltage) |
| Mains frequency | 50 Hz |
| 60 Hz | |
| Typical input current at UN | 6 mA (At 550 V AC, per line) |
| Current consumption | 6 mA (at 550 V AC) |
| Protective circuit | Surge protection |
| RC element; RC element | |
| Measurement | |
| Input name | Current measuring input L1/T1, L2/T2, L3/T3 |
| Mains frequency | 50 Hz |
| 60 Hz | |
| Typical input current at UN | max. 5 A |
| Power measurement | |
| Basic accuracy | ± 2 % (Of input value, type < ± 1 %, cosφ 0.7, tu 20 °C, I = 5 A) |
| Power range | 0.1 kW ... 5 kW (x transformation ratio of external current transducers) |
| Voltage measurement/star voltage | |
| Basic accuracy | ± 2 % (Of end value, typ. < ±0.5 %) |
| Voltage range | 0 V ... 318 V (Toward virtual star point) |
| Current measurement | |
| Basic accuracy | ± 2 % (Of end value, typ. < ±1 %) |
| Current range | 0.25 A ... 5 A (x transformation ratio of external current transducers) |
| Measuring via | Current transformer for any conductor current |
| Acknowledging contacts O1-O4 | |
| Note | The meaning of the acknowledgement outputs can be freely parameterized, see user manual |
| Number of outputs | 4 |
| Nominal output voltage | UVN- 1 V |
| Continuous load current | 50 mA |
| Residual voltage | < 1 V |
| Switching outputs 2 A | |
| Nominal output voltage | 24 V DC |
| Nominal output voltage range (factor) | 0.8 ... 1.2 |
| Continuous load current | 2 A |
| Protective circuit | Reverse polarity protection |
| Surge protection | |
| short-circuit and overload proof | |
| Control circuits | |
| Connection method | Screw connection |
| Stripping length | 8 mm |
| Screw thread | M3 |
| Conductor cross section rigid | 0.2 mm² ... 6 mm² |
| Conductor cross section flexible | 0.2 mm² ... 4 mm² |
| Conductor cross section AWG | 24 ... 10 |
| Load circuit | |
| Connection method | Screw connection |
| Stripping length | 8 mm |
| Screw thread | M3 |
| Conductor cross section rigid | 0.2 mm² ... 6 mm² |
| Conductor cross section flexible | 0.2 mm² ... 4 mm² |
| Conductor cross section AWG | 24 ... 10 |
| Data | |
| Interface | RS-232 |
| Transmission speed | 19200 bit (baud) |
| Width | 62 mm |
| Height | 107 mm |
| Depth | 120 mm |
| Color | green (RAL 6021) |
| Ambient conditions | |
| Degree of protection | IP20 |
| Ambient temperature (operation) | -20 °C ... 60 °C |
| Ambient temperature (storage/transport) | -20 °C ... 70 °C |
| Air clearances and creepage distances between the power circuits | |
| Standards/regulations | DIN EN 50178 |
| safe isolation | |
| Power station requirements | |
| Standards/regulations | DWR 1300/ZXX01/DD/7080.8d |
| EMC regulations | |
| Standards/regulations | EN 61000-6-2 |
| EN 61000-6-4 | |
| Assembly note | Can be aligned with > 20 mm spacing |
| Mounting position | Vertical (horizontal DIN rail) |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.