EMM W3/ 5-500 2963556 PHOENIX CONTACT Electronic motor management unit without power section View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

EMM W3/ 5-500 2963556 PHOENIX CONTACT Electronic motor management unit without power section

EMM W3/ 5-500

2963556

PHOENIX_CONTACT

Electronic motor management unit without power section

More details


Home > PHOENIX CONTACT

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete.

Go to successor article: EMM 3- 24DC/500AC-16-IFS 2297523

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Technical data

Product properties
Product typeElectronic motor manager
Operating mode100% operating factor

Electrical properties
Number of phases3
Mains type3-phase
Test voltage input/output2.5 kV
Supply
Input nameDevice supply
Nominal supply voltage24 V DC
Supply voltage range with reference to UVN0.8 ... 1.2
Quiescent current80 mA AC
Current consumption80 mA
Protective circuitReverse polarity protection; Series polarity protection diode
Surge protection
Operating voltage displayGreen LED
Error indicationRed LED
Status displayLED (yellow)
Supply
Input nameSupply voltage for 2 A digital outputs
Nominal supply voltage24 V DC ±20 %
Nominal input voltage UN24 V DC ±20 %
Typical input current at UN2 A

Input data
Control
Input nameControl input right/left
Nominal input voltage UN24 V DC
Input voltage range in reference to UN0.8 ... 1.2
0.8 ... 1.2
Typical input current at UN7 mA
Current consumption7 mA
Reaction time in normal load operation< 25 ms
Typical response time< 25 ms
Typical turn-off time< 25 ms
Reaction time in normal load operation< 25 ms
Status displayLED yellow, forward running (R), LED yellow, reverse running (L)
Measurement
Input nameVoltage measuring input V1, V2, V3
Input voltage range110 V AC ... 550 V AC (conductor voltage)
Mains frequency50 Hz
60 Hz
Typical input current at UN6 mA (At 550 V AC, per line)
Current consumption6 mA (at 550 V AC)
Protective circuitSurge protection
RC element; RC element
Measurement
Input nameCurrent measuring input L1/T1, L2/T2, L3/T3
Mains frequency50 Hz
60 Hz
Typical input current at UNmax. 5 A
Power measurement
Basic accuracy± 2 % (Of input value, type < ± 1 %, cosφ 0.7, tu 20 °C, I = 5 A)
Power range0.1 kW ... 5 kW (x transformation ratio of external current transducers)
Voltage measurement/star voltage
Basic accuracy± 2 % (Of end value, typ. < ±0.5 %)
Voltage range0 V ... 318 V (Toward virtual star point)
Current measurement
Basic accuracy± 2 % (Of end value, typ. < ±1 %)
Current range0.25 A ... 5 A (x transformation ratio of external current transducers)
Measuring viaCurrent transformer for any conductor current

Output data
Acknowledging contacts O1-O4
NoteThe meaning of the acknowledgement outputs can be freely parameterized, see user manual
Number of outputs4
Nominal output voltageUVN- 1 V
Continuous load current50 mA
Residual voltage< 1 V
Switching outputs 2 A
Nominal output voltage24 V DC
Nominal output voltage range (factor)0.8 ... 1.2
Continuous load current2 A
Protective circuitReverse polarity protection
Surge protection
short-circuit and overload proof

Connection data
Control circuits
Connection methodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section rigid0.2 mm² ... 6 mm²
Conductor cross section flexible0.2 mm² ... 4 mm²
Conductor cross section AWG24 ... 10
Load circuit
Connection methodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section rigid0.2 mm² ... 6 mm²
Conductor cross section flexible0.2 mm² ... 4 mm²
Conductor cross section AWG24 ... 10

Interfaces
Data
InterfaceRS-232
Transmission speed19200 bit (baud)

Dimensions
Width62 mm
Height107 mm
Depth120 mm

Material specifications
Colorgreen (RAL 6021)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP20
Ambient temperature (operation)-20 °C ... 60 °C
Ambient temperature (storage/transport)-20 °C ... 70 °C

Standards and regulations
Air clearances and creepage distances between the power circuits
Standards/regulationsDIN EN 50178
safe isolation
Power station requirements
Standards/regulationsDWR 1300/ZXX01/DD/7080.8d
EMC regulations
Standards/regulationsEN 61000-6-2
EN 61000-6-4

Mounting
Assembly noteCan be aligned with > 20 mm spacing
Mounting positionVertical (horizontal DIN rail)

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.