ELR 3/ 9-400 2941701 PHOENIX CONTACT Electronic load relay, for direct driving of equipment in the 3-phase n.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

ELR 3/ 9-400 2941701 PHOENIX CONTACT Electronic load relay, for direct driving of equipment in the 3-phase n..

ELR 3/ 9-400

2941701

PHOENIX_CONTACT

Available

Ship on today

Electronic load relay, for direct driving of equipment in the 3-phase network, with light indicator and protection circuit, output: 110-440 V AC/3 x 9 A

More details


Programmable Logic Controllers Plcs

INTERFACE Signal converters, switching devices, and power supply units - PHOENIX CONTACT

Solid state relays and power electronics. Relay - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+165,76 €
2+162,01 €
3+160,37 €
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Dimensions

Width62 mm
Height84 mm
Depth110 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 60 °C
Ambient temperature (storage/transport)-20 °C ... 70 °C
Degree of protectionIP20

Input data

Input nameDevice supply
Protective circuitProtection against polarity reversal Polarity protection diode
Surge protection
Status displayYellow LED
Input nameControl input right/left
Nominal input voltage UN24 V DC
Input voltage range in reference to UN0.8 ... 1.2
Typical input current at UN16 mA
Reaction time in normal load operation20 ms
Transmission frequency1 Hz (At cos φ = 0.5)

Output data

Output nameAC output
Nominal output voltage400 V AC
Nominal output voltage range110 V AC ... 440 V AC
Periodic peak reverse voltage800 V
Mains frequency50 Hz
60 Hz
Leakage currenttyp. 7 mA
Residual voltagetyp. 1.5 V
Surge current230 A (tp = 10 ms, at 25 °C)
Type of protectionRC element
Protective circuit/componentRC element
Type of protectionSurge protection
Surge voltage protection> 750 V

Connection data, control circuit

Connection nameControl circuits
Connection methodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section solid0.2 mm² ... 6 mm²
Conductor cross section flexible0.2 mm² ... 4 mm²
Conductor cross section AWG24 ... 10

General

Test voltage input/output2.5 kV
Switching frequencymax. 10 Hz (At cos φ = 0.5)
Mounting positionVertical (horizontal DIN rail)
Assembly instructionsCan be aligned with > 20 mm spacing
Operating mode100% operating factor
DesignationAir clearances and creepage distances between the power circuits
Standards/regulationsEN 50178
Basic insulation
DesignationPower station requirements
EMC regulations
Standards/regulationsEN 61000-6-2
EN 61000-6-4

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2941701-ELR 3/ 9-400English118 KbytesPHOENIX CONTACT-2941701-ELR 3/ 9-400