QUINT-DIODE/12-24DC/2X20/1X40 2320157 PHOENIX CONTACT Diode View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

QUINT-DIODE/12-24DC/2X20/1X40 2320157 PHOENIX CONTACT Diode

QUINT-DIODE/12-24DC/2X20/1X40

2320157

PHOENIX_CONTACT

Diode

More details


Power Supplies (PS)

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total price: $224.86
Unit price: $224.86

Quantity Price
1+$224.86
2+$200.16
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Often bought together

More info



Key Commercial Data

Orderkey2320157
Packing unit1 pc
Catalog pagePage 212 (C-6-2015)
GTIN4046356524766
Weight per Piece (excluding packing)750.000 g
Custom tariff number85049091
Country of originCN (China)

Dimensions

Width50 mm
Height130 mm
Depth125 mm

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)-40 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Climatic class3K3 (in acc. with EN 60721)
Degree of pollution2
Installation height2000 m

Input data

Nominal input voltage range12 V DC ... 24 V DC
12 V DC ... 24 V DC
Input voltage range10 V DC ... 30 V DC
10 V DC ... 30 V DC
Nominal input current2x 20 A (-25 °C ... 60 °C)
1x 40 A (-25 °C ... 60 °C)
Maximum input current2x 30 A (-25°C ... 40°C)
1x 60 A (-25°C ... 40°C)
Nominal input current2x 20 A (-25 °C ... 60 °C)
1x 40 A (-25 °C ... 60 °C)
Maximum input current2x 30 A (-25°C ... 40°C)
1x 60 A (-25°C ... 40°C)

Output data

Setting range of the output voltage (USet)12 V DC ... 24 V DC
Nominal output current (IN)40 A (Increasing power)
20 A (Redundancy)
Derating60 °C ... 70 °C (2.5%/K)
Connection in seriesNo
Power loss nominal load max.10 W (IOUT= 20 A)

General

Net weight0.75 kg
Efficiency> 97 %
> 97 %
Protection classIII
Degree of protectionIP20
MTBF (IEC 61709, SN 29500)40000000 h
Mounting positionhorizontal DIN rail NS 35, EN 60715
Assembly instructionsalignable: PN≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically
alignable: PN<50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom

Connection data, input

Connection methodScrew connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.6 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.4 mm²
Conductor cross section AWG min.12
Conductor cross section AWG max.10
Stripping length7 mm
Screw threadM3

Connection data, output

Connection methodScrew connection
Conductor cross section solid min.0.5 mm²
Conductor cross section solid max.16 mm²
Conductor cross section flexible min.0.5 mm²
Conductor cross section flexible max.16 mm²
Conductor cross section AWG min.10
Conductor cross section AWG max.6
Stripping length10 mm
Screw threadM4

Standards and Regulations

Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Connection in acc. with standardCUL
Standards/regulationsEN 61000-4-2
Contact discharge8 kV (Contact discharge)
Standards/regulationsEN 61000-4-3
Frequency range80 MHz ... 1 GHz
Test field strength20 V/m
Frequency range1 GHz ... 3 GHz
Test field strength10 V/m
Standards/regulationsEN 61000-4-4
CommentsCriterion A
Standards/regulationsEN 61000-6-3
EN 61000-4-6
Frequency range0.15 MHz ... 80 MHz
Voltage10 V
Low Voltage DirectiveConformance with Low Voltage Directive 2006/95/EC
Standard - Electrical safetyEN 60950-1/VDE 0805 (SELV)
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)
Standard – Safety extra-low voltageIEC 60950-1 (SELV) and EN 60204-1 (PELV)
Standard - Safe isolationDIN VDE 0100-410
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipmentEN 50178
UL approvalsUL/C-UL listed UL 508
UL/C-UL Recognized UL 60950-1
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
Shock18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation)< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
15 Hz ... 150 Hz, 2.3g, 90 min.
ATEX II 3G Ex nA IIC T4 Gc
KEMA 10 ATEX 0165X
IECExEx nA IIC T4 Gc
IECEx KEM 10.0091

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 25;
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.