Product successfully added to your shopping cart
RAD-DI4-IFS
2901535
PHOENIX_CONTACT
1
I/O extension module
Safety
* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Orderkey | 2901535 |
---|---|
Packing unit | 1 pc |
Catalog page | Page 460 (C-6-2017) |
GTIN | 4046356610490 |
Weight per Piece (excluding packing) | 163.200 g |
Custom tariff number | 85177000 |
Country of origin | DE (Germany) |
Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
---|
Degree of protection | IP20 |
---|---|
Ambient temperature (operation) | -40 °C ... 70 °C |
-40 °F ... 158 °F | |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
-40 °F ... 185 °F | |
Permissible humidity (operation) | 20 % ... 85 % |
Permissible humidity (storage/transport) | 20 % ... 85 % |
Altitude | 2000 m |
Vibration (operation) | in accordance with IEC 60068-2-6: 5g, 10 Hz ... 150 Hz |
Shock | 16g, 11 ms |
Overvoltage category | II |
---|---|
Mounting position | any |
Assembly instructions | on standard DIN rail NS 35 in accordance with EN 60715 |
Degree of pollution | 2 |
Housing material | PA 6.6-FR |
Flammability rating according to UL 94 | V0 |
MTTF | 1766 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) |
653 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day)) | |
250 Years (Telcordia standard, temperature 40 °C, operating cycle 100 % (7 days a week, 24 hours a day)) |
Supply voltage range | 19.2 V DC ... 30.5 V DC (DIN rail connector) |
---|---|
Max. current consumption | ≤ 11 mA (At 24 V DC, at 25°C) |
Transient surge protection | Yes |
Description of the input | Digital input |
---|---|
Number of inputs | 4 |
Switching level "1" signal | 10 V AC/DC ... 50 V AC/DC (Low-voltage input) |
50 V AC/DC ... 250 V AC/DC (High-voltage input) | |
Switching level "0" signal | 0 V AC/DC ... 4 V AC/DC (Low-voltage input) |
0 V AC/DC ... 20 V AC/DC (High-voltage input) | |
Input frequency | ≤ 2 Hz |
Min. voltage input signal | 0 V AC/DC |
Max. voltage input signal | 250 V AC/DC |
Digital I/O | 300 V (Rated insulation voltage (in each case between the digital inputs // TBUS supply, reinforced insulation according to EN 61010)) |
---|
Connection method | Screw connection |
---|---|
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 14 |
Stripping length | 7 mm |
Tightening torque | 0.6 Nm |
Screw thread | M3 |
Status display | Green LED (supply voltage, PWR) |
---|---|
Green LED (bus communication, DAT) | |
Red LED (periphery error, ERR) | |
Yellow LED (digital input, DI1) | |
Yellow LED (digital input, DI2) | |
Yellow LED (digital input, DI3) | |
Yellow LED (digital input, DI4) |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
---|---|
Standard designation | EMC Directive 2014/30/EU |
Standards/regulations | EN 61000-6-2 |
Standard designation | EMC Directive 2014/30/EU |
Standards/regulations | EN 61000-6-4 |
Standard designation | Ex Directive (ATEX) |
Standards/regulations | EN 60079-0 |
Standard designation | Ex Directive (ATEX) |
Standards/regulations | EN-60079-15 |
Noise emission | EN 61000-6-4 |
Noise immunity | EN 61000-6-2 |
Flammability rating according to UL 94 | V0 |
Shock | 16g, 11 ms |
Vibration (operation) | in accordance with IEC 60068-2-6: 5g, 10 Hz ... 150 Hz |
Conformance | CE-compliant |
ATEX | II 3 G Ex nA IIC T4 Gc |
IECEx | Ex nA IIC T4 Gc |
UL, USA/Canada | UL 508 Listed |
Class I, Div. 2, Groups A, B, C, D T4A | |
Class I, Zone 2, IIC T4 | |
Noxious gas test | ISA-S71.04-1985 G3 Harsh Group A |
China RoHS | Environmentally Friendly Use Period = 50 |
---|---|
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
Title: | Size: | Type: |
---|---|---|
PDF CATALOG PHOENIX AUTOMATION EN.pdf | 35 Mbytes | |
PHOENIX CONTACT-2901535-RAD-DI4-IFS | 921 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.