SC 2,5-RZ/ 2 3041516 PHOENIX CONTACT COMBI receptacle View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

SC 2,5-RZ/ 2 3041516 PHOENIX CONTACT COMBI receptacle

SC 2,5-RZ/ 2

3041516

PHOENIX_CONTACT

50

COMBI receptacle

More details


Modular TBs

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Quantity Price
50+$2.54
100+$2.17
150+$2.01
200+$1.98
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Key Commercial Data

Orderkey3041516
Packing unit50 pc
Minimum order quantity50 pc
NoteMade to Order (non-returnable)
Catalog pagePage 316 (C-1-2017)
GTIN4017918922733
Weight per Piece (excluding packing)7.000 g
Custom tariff number85366990
Country of originPL (Poland)

General

Number of positions2
Number of levels1
Number of connections1
Nominal cross section2.5 mm²
Colorgray
Insulating materialPA
Flammability rating according to UL 94V0
Maximum load current24 A (with a 2.5 mm² conductor cross section)
Rated surge voltage6 kV
Degree of pollution3
Overvoltage categoryIII
Insulating material groupI
Maximum power dissipation for nominal condition0.77 W
Maximum load current24 A (with 4 mm² conductor cross section)
Nominal current IN24 A
Nominal voltage UN500 V
Open side panelYes
Insertion/withdrawal cycles mechanical100
Result of surge voltage testTest passed
Surge voltage test setpoint7.3 kV
Result of power-frequency withstand voltage testTest passed
Power frequency withstand voltage setpoint1.89 kV
Result of tight fit on supportTest passed
Tight fit on carrierMetal wall 1 mm
Setpoint1 N
Short circuit stability resultTest passed
Conductor cross section short circuit testing2.5 mm²
Short-time current0.3 kA
Result of thermal testTest passed
Proof of thermal characteristics (needle flame) effective duration30 s
Oscillation, broadband noise test resultTest passed
Test specification, oscillation, broadband noiseDIN EN 50155 (VDE 0115-200):2008-03
Test spectrumService life test category 1, class B, body mounted
Test frequencyf1= 5 Hz to f2= 150 Hz
ASD level0.964 (m/s2)2/Hz
Acceleration0.58 g
Test duration per axis5 h
Test directionsX-, Y- and Z-axis
Shock test resultTest passed
Test specification, shock testDIN EN 50155 (VDE 0115-200):2008-03
Shock formHalf-sine
Acceleration5 g
Shock duration30 ms
Number of shocks per direction3
Test directionsX-, Y- and Z-axis (pos. and neg.)
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))130 °C
Static insulating material application in cold-60 °C
Behavior in fire for rail vehicles (DIN 5510-2)Test passed
Flame test method (DIN EN 60695-11-10)V0
Oxygen index (DIN EN ISO 4589-2)>32 %
NF F16-101, NF F10-102 Class I2
NF F16-101, NF F10-102 Class F2
Surface flammability NFPA 130 (ASTM E 162)passed
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Smoke gas toxicity NFPA 130 (SMP 800C)passed
Calorimetric heat release NFPA 130 (ASTM E 1354)28 MJ/kg
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

Dimensions

Width10.4 mm
End cover width2.2 mm
Length37.2 mm
Height21.8 mm
Hole diameter3.5 mm
Drill hole spacing5.2 mm
Plate thickness0.8 mm ... 1.5 mm
Pitch5.2 mm

Connection data

Connection methodSpring-cage connection
Stripping length8 mm ... 10 mm
Connection in acc. with standardIEC 61984
Conductor cross section solid min.0.08 mm²
Conductor cross section solid max.4 mm²
Conductor cross section AWG min.28
Conductor cross section AWG max.12
Conductor cross section flexible min.0.08 mm²
Conductor cross section flexible max.2.5 mm²
Min. AWG conductor cross section, flexible28
Max. AWG conductor cross section, flexible14
Conductor cross section flexible, with ferrule without plastic sleeve min.0.14 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.2.5 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min.0.14 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.2.5 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max.0.5 mm²
Internal cylindrical gageA3

Standards and Regulations

Connection in acc. with standardCUL
IEC 61984
Flammability rating according to UL 94V0
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.