VAL-MS-T1/T2 335/12.5 ST 2800190 PHOENIX CONTACT L-N replacement plug for VAL-MS-T1/T2 335/12.5 plug-in ligh.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

VAL-MS-T1/T2 335/12.5 ST 2800190 PHOENIX CONTACT L-N replacement plug for VAL-MS-T1/T2 335/12.5 plug-in ligh..

VAL-MS-T1/T2 335/12.5 ST

2800190

PHOENIX_CONTACT

10

Available

Ship on today

L-N replacement plug for VAL-MS-T1/T2 335/12.5 plug-in lighting/surge arrester.

More details


Overvoltage Protection Over Voltage

TRABTECH Power and Signal Quality - PHOENIX CONTACT

Surge protection - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
10+63,45 €
20+63,26 €
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Dimensions

Height47 mm
Width17.7 mm
Depth67.3 mm
Horizontal pitch1 Div.

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)-40 °C ... 80 °C
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 m (amsl (above mean sea level))
Permissible humidity (operation)5 % ... 95 %
Shock (operation)30g (half sinus / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (operation)7.5g (10 ... 500 Hz / 2.5 h / X, Y, Z)

General

IEC power supply systemTN-C
TN-S
TT
Housing materialPA 6.6
PBT
Flammability rating according to UL 94V-0
Colorjet black RAL 9005
Standards for cearances and creepage distancesDIN EN 60664-1
EN 61643-1
Mounting typeOn base element
TypeDIN rail module, two-section, divisible
Surge protection fault messageoptical
Direction of actionL-N / L-PEN

Protective circuit

IEC test classificationI / II
T1 / T2
T1
EN typeT1 / T2
T1
Nominal voltage UN240/415 V AC (TN-C, TN-S)
Maximum continuous operating voltage UC335 V AC
Nominal frequency fN50 Hz (60 Hz)
Residual current IPE≤ 800 µA
Standby power consumption PC≤ 270 mVA
Max. discharge current Imax (8/20) µs50 kA
Nominal discharge current In (8/20) µs12.5 kA
Voltage protection level Up≤ 1.2 kV
≤ 1.6 kV (30 kA - 8/20µs)
Response time tA≤ 25 ns
Max. backup fuse with branch wiring160 A AC (gG)
Short-circuit current rating ISCCR25 kA

Connection, protective circuit

Connection type INFLASHTRAB/VALVETRAB plug-in system
Connection type OUTFLASHTRAB/VALVETRAB plug-in system

Standards and Regulations

Standards/regulationsIEC 61643-11 2011
EN 61643-11 2012

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2800190-VAL-MS-T1/T2 335/12.5 STEnglish119 KbytesPHOENIX CONTACT-2800190-VAL-MS-T1/T2 335/12.5 ST

Reviews (0)