Product successfully added to your shopping cart
MINI MCR-2-POT-UI-PT
2902017
PHOENIX_CONTACT
1
Resistance/potiposition transducer
Configurable potentiometer position converter with plug-in connection technology for connecting potentiometers from 0 Ω ... 100 Ω at 0 kΩ ... 100 kΩ. Configurable via DIP switch or software. Push-in connection technology, standard configuration
Sensors > Isolation amplifier
INTERFACE Components (IF)
Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Utilization restriction | |
| EMC note | EMC: class A product, see manufacturer's declaration in the download area |
| Product type | Potiposition transducer |
| Product family | MINI Analog Pro |
| No. of channels | 1 |
| Configuration | DIP switches |
| Software | |
| App | |
| Data management status | |
| Article revision | 14 |
| Insulation characteristics | |
| Overvoltage category | II |
| Pollution degree | 2 |
| Functionality | |
| Configuration | DIP switches |
| Software | |
| App | |
| Electrical isolation | 3-way isolation |
| Protective circuit | Transient protection |
| Step response (0–99%) | < 60 ms |
| Maximum temperature coefficient | 0.01 %/K |
| Temperature coefficient, typical | 0.01 %/K |
| Maximum transmission error | < 0.1 % (R < 240 Ω = < 0,2 %) |
| Electrical isolation Input/output/power supply | |
| Rated insulation voltage | 300 Vrms |
| Test voltage | 3 kV AC (50 Hz, 60 s) |
| Insulation | Reinforced insulation according to IEC/EN 61010-1 |
| Supply | |
| Nominal supply voltage | 24 V DC |
| Supply voltage range | 9.6 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715) |
| Typical current consumption | 33 mA (24 V DC) |
| 68 mA (12 V DC) | |
| Power consumption | ≤ 850 mW (at IOUT= 20 mA, 9.6 V DC, 600 Ω load) |
| Signal: Resistance | |
| Number of inputs | 1 |
| Available input sources | 3-wire potentiometer |
| Resistance range | 0 Ω ... 100 Ω |
| 0 Ω ... 100 kΩ | |
| Signal: Voltage/current | |
| Number of outputs | 1 |
| Voltage output signal | 1 V ... 5 V (via DIP switch) |
| 10 V ... 0 V (via DIP switch) | |
| 0 V ... 5 V (via DIP switch) | |
| 0 V ... 10 V (via DIP switch) | |
| 0 V ... 10.5 V (can be set via software) | |
| Max. voltage output signal | 12.3 V |
| Non-load voltage | < 17.5 V |
| Current output signal | 0 mA ... 20 mA (via DIP switch) |
| 4 mA ... 20 mA (via DIP switch) | |
| 20 mA ... 0 mA (via DIP switch) | |
| 20 mA ... 4 mA (via DIP switch) | |
| 0 mA ... 21 mA (can be set via software) | |
| Max. current output signal | 24.6 mA |
| Short-circuit current | < 31.5 mA |
| Load/output load voltage output | ≥ 10 kΩ |
| Load/output load current output | ≤ 600 Ω (20 mA) |
| Ripple | < 20 mVPP |
| < 20 mVPP(10 kΩ) | |
| Resolution, outputs (voltage) | 1 mV |
| Resolution, outputs (current) | 2 µA |
| Behavior in the event of a sensor error | configurable |
| Connection method | Push-in connection |
| Stripping length | 10 mm |
| Conductor cross section rigid | 0.2 mm² ... 2.5 mm² (with ferrule) |
| 0.14 mm² ... 2.5 mm² (without ferrule) | |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| Conductor cross section AWG | 24 ... 12 (flexible) |
| Ex installation (EPL) | Gc |
| Div. 2 |
| Data: IFS interface | |
| Connection method | Micro USB type B |
| Operating voltage display | Green LED |
| Error indication | Red LED |
| Width | 6.2 mm |
| Height | 109.81 mm |
| Depth | 119.2 mm |
| Color | gray (RAL 7042) |
| Housing material | PBT |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 2 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 2 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 2 |
| Ambient conditions | |
| Degree of protection | IP20 (not assessed by UL) |
| Ambient temperature (operation) | -40 °C ... 70 °C |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Altitude | ≤ 2000 m |
| Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
| CE | |
| Certificate | CE-compliant |
| ATEX | |
| Identification | II 3 G Ex ec IIC T4 Gc |
| Certificate | BVS 20 ATEX E 024 X |
| UKCA Ex (UKEX) | |
| Identification | II 3 G Ex ec IIC T4 Gc |
| Certificate | PxCIF21UKEX2902049X |
| IECEx | |
| Identification | Ex ec IIC T4 Gc |
| Certificate | IECEx BVS 20.0017X |
| UL, USA/Canada | |
| Identification | UL 508 Listed |
| Class I, Div. 2, Groups A, B, C, D T5 | |
| Class I, Zone 2, Group IIC T5 | |
| Shipbuilding approval | |
| Certificate | DNV GL TAA00002UA |
| EAC Ex | |
| Identification | 2Ex ec IIC T4 Gc |
| Certificate | BY/112 02.01 TP012 103.01 00079 |
| DNV GL data | |
| Temperature | B |
| Humidity | B |
| Vibration | A |
| EMC | A |
| Enclosure | Required protection according to the Rules shall be provided upon installation on board |
| Electromagnetic compatibility | Conformance with EMC directive |
| Noise immunity | EN 61000-6-2 |
| Note | When being exposed to interference, there may be minimal deviations. |
| Noise emission | EN 61000-6-4 |
| Electrostatic discharge | |
| Standards/regulations | EN 61000-4-2 |
| Electrostatic discharge | |
| Comments | Safety measures must be taken to prevent electrostatic discharge. |
| Electromagnetic HF field | |
| Designation | Electromagnetic RF field |
| Standards/regulations | EN 61000-4-3 |
| Typical deviation from the measuring range final value | 0.2 % |
| Fast transients (burst) | |
| Designation | Fast transients (burst) |
| Standards/regulations | EN 61000-4-4 |
| Typical deviation from the measuring range final value | 0.4 % |
| Surge current load (surge) | |
| Standards/regulations | EN 61000-4-5 |
| Conducted interference | |
| Designation | Conducted interferences |
| Standards/regulations | EN 61000-4-6 |
| Typical deviation from the measuring range final value | 0.2 % |
| Electrical isolation | 3-way isolation |
| Mounting type | DIN rail mounting |
| Assembly note | The DIN rail connector can be used for bridging the supply voltage. It can be snapped onto a 35 mm EN 60715 DIN rail. |
| Mounting position | any |
| Feature Name | Feature Value |
|---|---|
| Type of power supply (EF001469) | Other |
| Rated supply voltage DC (EF007078) | 9.6 V |
| Number of input ranges -60 mV ... +60 mV (EF006927) | 0 |
| Number of input ranges -100 mV ... +100 mV (EF006912) | 0 |
| Number of input ranges -300 mV ... +300 mV (EF006920) | 0 |
| Number of input ranges -500 mV ... +500 mV (EF006926) | 0 |
| Number of input ranges -1 V ... +1 V (EF006906) | 0 |
| Number of input ranges -2 V ... +2 V (EF006913) | 0 |
| Number of input ranges -2.5 V ... +2.5 V (EF006915) | 0 |
| Number of input ranges -5 V ... +5 V (EF006923) | 0 |
| Number of input ranges -10 V ... +10 V (EF006909) | 0 |
| Number of input ranges -20 V ... +20 V (EF006917) | 0 |
| Number of input ranges 0 mV ... 60 mV (EF006905) | 0 |
| Number of input ranges 0 mV ... 100 mV (EF006893) | 0 |
| Number of input ranges 0 mV ... 200 mV (EF006898) | 0 |
| Number of input ranges 0 mV ... 300 mV (EF006901) | 0 |
| Number of input ranges 0 mV ... 500 mV (EF006904) | 0 |
| Number of input ranges 0 V ... 1 V (EF006890) | 0 |
| Number of input ranges 0 V ... 2 V (EF006894) | 0 |
| Number of input ranges 0 V ... 2.5 V (EF006895) | 0 |
| Number of input ranges 0 V ... 5 V (EF006903) | 0 |
| Number of input ranges 0 V ... 10 V (EF006892) | 0 |
| Number of input ranges 0 V ... 20 V (EF006897) | 0 |
| Number of input ranges 0 V ... 24 V (EF006899) | 0 |
| Number of input ranges 0 V ... 30 V (EF006900) | 0 |
| Number of input ranges 1 V ... 5 V (EF006907) | 0 |
| Number of input ranges 2 V ... 10 V (EF006914) | 0 |
| Number of input ranges +5 V ... -5 V (EF006889) | 0 |
| Number of input ranges +10 V ... -10 V (EF006888) | 0 |
| Number of input ranges 5 V ... 0 V (EF006924) | 0 |
| Number of input ranges 5 V ... 1 V (EF006925) | 0 |
| Number of input ranges 10 V ... 0 V (EF006910) | 0 |
| Number of input ranges 10 V ... 2 V (EF006911) | 0 |
| Number of input ranges 0 mA ... 5 mA (EF006902) | 0 |
| Number of input ranges 0 mA ... 10 mA (EF006891) | 0 |
| Number of input ranges 0 mA ... 20 mA (EF006896) | 0 |
| Number of input ranges 4 mA ... 20 mA (EF006921) | 0 |
| Number of input ranges -5 mA ... +5 mA (EF006922) | 0 |
| Number of input ranges -10 mA ... +10 mA (EF006908) | 0 |
| Number of input ranges -20 mA ... +20 mA (EF006916) | 0 |
| Number of input ranges 20 mA ... 0 mA (EF006918) | 0 |
| Number of input ranges 20 mA ... 4 mA (EF006919) | 0 |
| Number of output ranges -60 mV ... +60 mV (EF006880) | 0 |
| Number of output ranges -100 mV ... +100 mV (EF006865) | 0 |
| Number of output ranges -300 mV ... +300 mV (EF006873) | 0 |
| Number of output ranges -500 mV ... +500 mV (EF006879) | 0 |
| Number of output ranges -1 V ... +1 V (EF006859) | 0 |
| Number of output ranges -2 V ... +2 V (EF006866) | 0 |
| Number of output ranges -2.5 V ... +2.5 V (EF006868) | 0 |
| Number of output ranges -5 V ... +5 V (EF006876) | 0 |
| Number of output ranges -10 V ... +10 V (EF006862) | 0 |
| Number of output ranges -20 V ... +20 V (EF006870) | 0 |
| Number of output ranges 0 mV ... 60 mV (EF006858) | 0 |
| Number of output ranges 0 mV ... 100 mV (EF006846) | 0 |
| Number of output ranges 0 mV ... 200 mV (EF006851) | 0 |
| Number of output ranges 0 mV ... 300 mV (EF006854) | 0 |
| Number of output ranges 0 mV ... 500 mV (EF006857) | 0 |
| Number of output ranges 0 V ... 1 V (EF006843) | 0 |
| Number of output ranges 0 V ... 2 V (EF006847) | 0 |
| Number of output ranges 0 V ... 2.5 V (EF006848) | 0 |
| Number of output ranges 0 V ... 5 V (EF006856) | 1 |
| Number of output ranges 0 V ... 10 V (EF006845) | 1 |
| Number of output ranges 0 V ... 20 V (EF006850) | 0 |
| Number of output ranges 0 V ... 24 V (EF006852) | 0 |
| Number of output ranges 0 V ... 30 V (EF006853) | 0 |
| Number of output ranges 1 V ... 5 V (EF006860) | 1 |
| Number of output ranges 2 V ... 10 V (EF006867) | 0 |
| Number of output ranges +5 V ... -5 V (EF006842) | 0 |
| Number of output ranges +10 V ... -10 V (EF006841) | 0 |
| Number of output ranges 5 V ... 0 V (EF006877) | 0 |
| Number of output ranges 5 V ... 1 V (EF006878) | 0 |
| Number of output ranges 10 V ... 0 V (EF006863) | 1 |
| Number of output ranges 10 V ... 2 V (EF006864) | 0 |
| Number of output ranges 0 mA ... 5 mA (EF006855) | 0 |
| Number of output ranges 0 mA ... 10 mA (EF006844) | 0 |
| Number of output ranges 0 mA ... 20 mA (EF006849) | 1 |
| Number of output ranges 4 mA ... 20 mA (EF006874) | 1 |
| Number of output ranges -5 mA ... +5 mA (EF006875) | 0 |
| Number of output ranges -10 mA ... +10 mA (EF006861) | 0 |
| Number of output ranges -20 mA ... +20 mA (EF006869) | 0 |
| Number of output ranges 20 mA ... 0 mA (EF006871) | 1 |
| Number of output ranges 20 mA ... 4 mA (EF006872) | 1 |
| Number of channels (EF000259) | 1 |
| Malfunction message output (EF007499) | No |
| Inherently safe according to EN 60947-5-6 NAMUR (EF007112) | No |
| SIL according to IEC 61508 (EF009889) | None |
| Height (EF000040) | 109.81 mm |
| Width (EF000008) | 6.2 mm |
| Depth (EF000049) | 119.2 mm |
| Power consumption (EF000346) | 0.85 W |
| Load (EF007096) | 600 Ohm |
| Operating temperature (EF002393) | -40 °C |
| Temperature drift (EF007507) | 0.01 %/K |
| Construction type of device (EF007276) | Built-in device |
| Type of electric connection (EF003961) | Other |
| Mounting method (EF000003) | Snap mounting support rail |
| Degree of protection (IP) (EF005474) | IP20 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG PHOENIX INTERFACE TECHNOLOGY AND SWITCHING DEVICES EN.pdf | 29 Mbytes |
|
| PHOENIX CONTACT-2902017-MINI MCR-2-POT-UI-PT | 134 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.