PHOENIX CONTACT  SAC-5P-M12MSB/ 2,0-900 1507065 - Image 1

Images are for illustrative purposes only. Please refer to data sheet for details.

SAC-5P-M12MSB/ 2,0-900 1507065 PHOENIX CONTACT Bus system cable

Reference: SAC-5P-M12MSB/ 2,0-900

Code: 1507065

Manufacturer: PHOENIX CONTACT

Description:

Bus system cable
Bus system cable, INTERBUS (16 MBit/s), 5-pole halogen-free, shielded, Straight M12 connector, encoding: B, to free cable end, cable length: 2 m
Bus system cable, INTERBUS (16 Mbps), 5-position, PUR halogen-free, may green RAL 6017, shielded, Plug straight M12, coding: B, on free cable end, cable length: 2 m

Categories:

  • Sensors > Sensor-actuator patch cord
  • PHOENIX CONTACT > Industrial Field Connectivity (IFC)

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX CONTACT

  • More Info
  • ETIM
  • PDF
  • Reviews
Guarantee, repair and return.

Unit Price: 27,42 €

This price is per unit and is the net value (not including taxes if applicable).

Calculate price by quantity

QuantityPrice

Standard lead time: 2-3 weeks.

  • These delivery times are an estimate any may vary when the item order has been processed.

LAST VIEWED

MORE INFO

Technical data

Notes
GeneralFurther products with variable cable type and variable cable length can be found in the accessories section

Product properties
Product typeData cable preassembled
ApplicationStandard
Sensor typeINTERBUS
Number of positions5
No. of cable outlets1
Shieldedyes
CodingB
Insulation characteristics
Overvoltage categoryII
Degree of pollution3

Interfaces
Bus systemINTERBUS
Signal type/categoryINTERBUS, 16 Mbps

Signaling
Status displayno
Status display presentNo

Electrical properties
Insulation resistance≥ 100 MΩ
Nominal voltage UN48 V AC
60 V DC
Nominal current IN4 A
Transmission mediumCopper

Mechanical properties
Mechanical data
Insertion/withdrawal cycles≥ 100

Material specifications
Flammability rating according to UL 94V0
Material of grip bodyTPU, hardly inflammable, self-extinguishing
Contact materialCuSn
Contact surface materialNi/Au
Contact carrier materialPA 6.6
Material for screw connectionZinc die-cast, nickel-plated

Connection data
Pin assignment
Contact Color (signal designation) Contact (optional)1 (Plug) YE (DO)
2 (Plug) GN (DO)
3 (Plug) GY (DI)
4 (Plug) PK (DI)
5 (Plug) BN (GND)

Connector
Connection 1
TypePlug straight M12
Number of positions5
Coding typeB (inverse)
Connection 2
Typefree cable end

Cable/line
Cable length2 m
INTERBUS [900]
Dimensional drawingygwyytzvdn.jpg
Cable weight70 kg/km
Number of positions6
Shieldedyes
Cable typeINTERBUS [900]
Conductor structure3 x 2 x 0.22 mm²
Signal speed0.66 c
Conductor structure signal line32x 0.10 mm
AWG signal line24
Conductor cross section3x 2x 0.22 mm²
External cable diameter8.00 mm
Outer sheath, materialPUR
External sheath, colormay green RAL 6017
Conductor materialBare Cu litz wires
Material wire insulationPE
Single wire, colorgreen-yellow, white-brown, gray-pink
Twisted pairs2 cores to the pair
Overall twist3 pairs to the core
Insulation resistance≥ 5 GΩ*km
Coupling resistance< 250.00 mΩ/m (at 30 MHz)
Loop resistance≤ 159.80 Ω/km
Wave impedance120 Ω ±20 % (at 64 kHz)
100 Ω ±15 % (with 1 MHz)
Cable capacity≤ 60 nF/km (At 800 Hz)
Nominal voltage, cable250 V (Peak value, not for high-power applications)
Test voltage Core/Core1500 Vrms
Test voltage Core/Shield1000.00 Vrms
Minimum bending radius, fixed installation7.5 x D
Minimum bending radius, flexible installation15 x D
Smallest bending radius, fixed installation60 mm
Smallest bending radius, movable installation120 mm
Dynamic load capacity (bending)Max. bending cycles: 5000000, Bending radius: 120 mm, Traversing path: 10 m, Traversing rate: 1.6 m/s, Acceleration: 3.2 m/s²
Near end crosstalk attenuation (NEXT)≥ 61 dB (at 772 kHz)
≥ 59 dB (with 1 MHz)
≥ 55 dB (at 2 МHz)
≥ 50 dB (at 4 МHz)
≥ 46 dB (at 8 МHz)
≥ 44 dB (at 10 MHz)
≥ 41 dB (at 16 MHz)
≥ 40 dB (at 20 МHz)
Shield attenuation≤ 15 dB/km (at 256 kHz)
≤ 24 dB/km (at 772 kHz)
≤ 27 dB/km (with 1 MHz)
≤ 52 dB/km (at 4 МHz)
≤ 84 dB/km (at 10 MHz)
≤ 112 dB/km (at 16 MHz)
≤ 119 dB/km (at 20 МHz)
Flame resistanceaccording to VDE 0472, Part 4, test type B
according to IEC 60332-1
Ambient temperature (operation)-40 °C ... 80 °C (cable, fixed installation)
-30 °C ... 70 °C (Cable, flexible installation)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP65
IP67
Ambient temperature (operation)-25 °C ... 90 °C (Plug / socket)

ETIM for 1507065 Sensors (EC001855)

Feature nameNumber of poles (EF001391)
Feature value5
Feature nameType of electrical connection, field-sided (EF005525)
Feature valueOther
Feature namePositioning cable feed, field-sided (EF005928)
Feature valueOther
Feature nameCable length (EF000536)
Feature value2 m
Feature nameMaterial of cable sheath (EF004136)
Feature valueOther
Feature nameHalogen free (EF000025)
Feature valueYes
Feature nameColour cable sheath (EF008249)
Feature valueOther
Feature nameWith LED indication (EF005950)
Feature valueNo
Feature nameScreened (EF000881)
Feature valueYes
Feature nameVulcanize (EF004115)
Feature valueNo
Feature nameMaterial contact body (EF008248)
Feature valueOther
Feature nameMaterial of contact surface (EF004020)
Feature valueOther
Feature namePermitted cable outer temperature after assembling without vibration (EF001686)
Feature value-40 °C
Feature namePermitted cable outer temperature during assembling/handling (EF001685)
Feature value-30 °C
Feature nameRated current In (EF008250)
Feature value4 A
Feature nameRated voltage (EF000228)
Feature value48 V
Feature nameDegree of protection (IP) (EF005474)
Feature valueIP65

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.