Feed-through terminal block
Feed-through terminal block, with flange on the left side, connection type: Annular cable terminal, Push-in connection, width: 17.5 mm, color: black, mounting: NS 35/7.5, NS 35/15, Direct mounting with a cable tie
Terminal blocks > Feed-through terminal block
Modular TBs
Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Orderkey | 3281111 |
|---|---|
| Packing unit | 50 pc |
| Note | Made to Order (non-returnable) |
| GTIN | 4055626620558 |
| Weight per Piece (excluding packing) | 9.440 g |
| Custom tariff number | 85369010 |
| Country of origin | IN (India) |
| Number of levels | 1 |
|---|---|
| Number of connections | 3 |
| Nominal cross section | 2.5 mm² |
| Color | black |
| Insulating material | PC |
| Flammability rating according to UL 94 | V0 |
| Rated surge voltage | 8 kV |
| Degree of pollution | 3 |
| Overvoltage category | III |
| Insulating material group | IIIa |
| Maximum power dissipation for nominal condition | 0.77 W |
| Ambient temperature (operation) | -40 °C ... 110 °C |
| Connection method | Ring cable lug |
| Connection in acc. with standard | IEC 60947-7-1 |
| Maximum load current | 24 A |
| Nominal current IN | 24 A |
| Nominal voltage UN | 690 V |
| Connection method | Push-in connection |
| Connection in acc. with standard | IEC 60947-7-1 |
| Maximum load current | 24 A (The maximum load current must not be exceeded by the total current of all connected conductors.) |
| Nominal current IN | 24 A |
| Nominal voltage UN | 690 V |
| Open side panel | Yes |
| Connection method | Ring cable lug |
|---|---|
| Connection in acc. with standard | IEC 60947-7-1 |
| Screw thread | M3,5 |
| Tightening torque, min | 1 Nm |
| Tightening torque max | 1.2 Nm |
| Stripping length | 10 mm ... 12 mm |
| Conductor cross section solid min. | 0.5 mm² |
| Conductor cross section solid max. | 2.5 mm² |
| Conductor cross section flexible min. | 0.14 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Min. AWG conductor cross section, flexible | 26 |
| Max. AWG conductor cross section, flexible | 14 |
| Conductor cross section flexible, with ferrule with plastic sleeve min. | 0.2 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve max. | 2.5 mm² |
| Cable lug connection according to standard | DIN 46234 |
| Min. cross section for cable lug connection | 0.14 mm² |
| Max. cross section for cable lug connection | 2.5 mm² |
| AWG min | 26 |
| AWG max | 16 |
| Hole diameter, min. | 3.7 mm |
| Cable lug width, max. | 6.8 mm |
| Bolt diameter | 3.5 mm |
| Screw thread | M3,5 |
| Tightening torque, min | 1 Nm |
| Tightening torque max | 1.2 Nm |
| Connection method | Push-in connection |
| Connection in acc. with standard | IEC 60947-7-1 |
| Stripping length | 10 mm ... 12 mm |
| Conductor cross section solid min. | 0.14 mm² |
| Conductor cross section solid max. | 2.5 mm² |
| Conductor cross section AWG min. | 26 |
| Conductor cross section AWG max. | 14 |
| Conductor cross section flexible min. | 0.14 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Min. AWG conductor cross section, flexible | 26 |
| Max. AWG conductor cross section, flexible | 14 |
| Conductor cross section flexible, with ferrule without plastic sleeve min. | 0.14 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve max. | 1.5 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve min. | 0.14 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve max. | 1.5 mm² |
| Conductor cross section solid min. | 0.5 mm² |
| Conductor cross section solid max. | 2.5 mm² |
| Conductor cross section AWG min. | 20 |
| Conductor cross section AWG max. | 14 |
| Conductor cross section flexible, with ferrule with plastic sleeve min. | 0.34 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve max. | 1.5 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve min. | 0.34 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve max. | 1.5 mm² |
| Connection method | Ring cable lug |
|---|---|
| Connection in acc. with standard | JIS 8207-7-1 |
| Conductor cross section flexible min. | 0.5 mm² |
| Conductor cross section flexible max. | 2 mm² |
| Cable lug connection according to standard | JIS 8207-7-1 |
| Min. cross section for cable lug connection | 0.5 mm² |
| Max. cross section for cable lug connection | 2 mm² |
| Hole diameter, min. | 3.7 mm |
| Cable lug width, max. | 6.8 mm |
| Bolt diameter | 3.5 mm |
| Screw thread | M3,5 |
| Tightening torque, min | 1 Nm |
| Tightening torque max | 1.3 Nm |
| Nominal current IN | 21 A |
| Maximum load current | 21 A |
| Nominal voltage UN | 600 V |
| Connection method | Push-in connection |
| Connection in acc. with standard | JIS 8207-7-1 |
| Single-wire/terminal point, solid diameter min. | 0.5 mm |
| Single-wire/terminal point, solid diameter max. | 1.6 mm |
| Conductor cross section flexible min. | 0.5 mm² |
| Conductor cross section flexible max. | 2 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve min. | 0.5 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve max. | 2 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve min. | 0.5 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve max. | 2 mm² |
| Connection cross sections directly pluggable | 0.8 mm 1.6 mm |
| Single-wire/terminal point, solid diameter min. | 0.8 mm |
| Single-wire/terminal point, solid diameter max. | 1.6 mm |
| Conductor cross section flexible, with ferrule without plastic sleeve min. | 0.5 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve max. | 2 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve min. | 0.5 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve max. | 1.25 mm² |
| Connection in acc. with standard | IEC 60947-7-1 |
|---|---|
| IEC 60947-7-1 | |
| Flammability rating according to UL 94 | V0 |
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
|---|---|
| No hazardous substances above threshold values |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG PHOENIX TERMINAL BLOCKS EN.pdf | 69 Mbytes |
|
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.