Bolt connection terminal block, Connection method: Bolt connection, Number of positions: 3, Cross section: 6 mm²

More details


Enclosures connectivity

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



General

Number of levels1
Number of connections6
Nominal cross section70 mm²
Colorgray
Insulating materialPA
Flammability rating according to UL 94V0

General

Rated surge voltage8 kV
Pollution degree3
Overvoltage categoryIII
Insulating material groupI
Connection in acc. with standardIEC 60947-7-1
Maximum load current192 A (in case of a 70 mm² conductor cross section, the maximum load current must not be exceeded by the total current of all connected conductors.)
Nominal current IN192 A
Nominal voltage UN1000 V
Open side panelnein
Number of positions3

Dimensions

Width87 mm
Length136 mm
Height NS 35/7,567 mm
Height NS 35/1574.5 mm

Connection data

NoteConnection bolts
Connection methodBolt connection
Connection in acc. with standardIEC 60947-7-1
Conductor cross section solid min.6 mm²
Conductor cross section solid max.70 mm²
Conductor cross section AWG min.8
Conductor cross section AWG max.2/0
Conductor cross section flexible min.6 mm²
Conductor cross section flexible max.70 mm²
Min. AWG conductor cross section, flexible8
Max. AWG conductor cross section, flexible2/0
Cable lug connection according to standardDIN 46 234
Min. cross section for cable lug connection2.5 mm²
Max. cross section for cable lug connection70 mm²
Hole diameter8.4 mm
Width22 mm
Bolt diameter8 mm
Screw threadM8
Tightening torque, min6 Nm
Tightening torque max12 Nm
Cable lug connection according to standardDIN 46,235
Min. cross section for cable lug connection16 mm²
Max. cross section for cable lug connection70 mm²
Hole diameter8.4 mm
Width24 mm
Bolt diameter8 mm
Screw threadM8
Tightening torque, min6 Nm
Tightening torque max12 Nm
Screw threadM8
Tightening torque, min6 Nm
Tightening torque max12 Nm

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.