AXC F 1050 2404701 PHOENIX CONTACT Controller View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

AXC F 1050 2404701 PHOENIX CONTACT Controller

AXC F 1050

2404701

PHOENIX_CONTACT

Controller

Axial control for the Axioline direct I/O control system. With 2 Ethernet interfaces and programmability in accordance with IEC 61131-3. Complete with connector and labeling surface.

More details


Control Systems (CST)

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Key Commercial Data

Orderkey2404701
Packing unit1 pc
NoteMade to Order (non-returnable)
GTIN4055626426310
Weight per Piece (excluding packing)225.600 g
Custom tariff number85371091
Country of originDE (Germany)

Dimensions

Width45 mm
Height125.9 mm
Depth74 mm

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)-25 °C ... 60 °C up to 2000 m above mean sea level
-25 °C ... 55 °C up to 3000 m above mean sea level
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (according to DIN EN 61131-2, non-condensing, no ice formation)
Permissible humidity (storage/transport)10 % ... 95 % (according to DIN EN 61131-2, non-condensing, no ice formation)
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)58 kPa ... 106 kPa (up to 4500 m above mean sea level)
Shock30g, 11 ms period, half-sine shock pulse, according to IEC 60068-2-27
Vibration (operation)5g

Control system

Engineering toolPLCnext Engineer
Programming languages supportedProgramming in acc. with IEC 61131-3
Configuration toolConfig+ Version 1.01 or later

IEC 61131 runtime system

Engineering toolPLCnext Engineer
Program memory2 Mbyte
Mass storage2 Mbyte
Retentive mass storage48 kByte (NVRAM)
Number of control tasks8
Realtime clockYes

Fieldbus function

Designation
Amount of process datamax. 4096 Bit (Axioline F local bus (input))
max. 4096 Bit (Axioline F local bus (output))
max. 32768 Bit (per station)
Number of supported devicesmax. 63 (per station)
Number of local bus devices that can be connectedmax. 63 (observe current consumption)

Data interfaces

InterfaceAxioline F local bus
Number1
Connection methodBus base module
Transmission speed100 Mbps
InterfaceService
Number1
Connection methodMicro USB type B
Transmission speedmax. 115.2 kbps
InterfaceEthernet
Number2
Connection methodRJ45 socket
Transmission speed10/100 Mbps

PROFINET

Device functionPROFINET controller, PROFINET device
SpecificationVersion 2.3
Update ratemin. 32 ms (16 devices)
min. 32 ms (8 devices)
min. 16 ms (4 devices)
min. 8 ms (2 devices)
min. 4 ms (1st device)

Power supply

Supply voltage range19.2 V DC ... 30 V DC
Power dissipationmax. 3 W

Mechanical design

Weight225.6 g

General data

ProcessorAltera Nios II 1x 100 MHz

Standards and Regulations

Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Interference emissionNoise emission test according to EN 61000-6-3 Radio noise emission EN 55032 Class B
Immunity to surgeNoise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), fieldbus cable shield: ±1 kV
Immunity to burstNoise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
Immunity to EFNoise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
Immunity to ESDNoise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
Immunity to conducted interferenceNoise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A; Test voltage 10 V
Vibration (storage/transport)5g
Shock30g, 11 ms period, half-sine shock pulse, according to IEC 60068-2-27
Vibration (operation)5g
Shock (operation)10g (Bump endurance test according to EN 60068-2-29)

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications


Datasheet - PDF

Title: Size: Type:
PDF CATALOG PHOENIX AUTOMATION EN .pdf 35 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.