DT-TELE-RJ45 2882925 PHOENIX CONTACT Attachment plug with surge protection for analog and digital telecommun.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

DT-TELE-RJ45 2882925 PHOENIX CONTACT Attachment plug with surge protection for analog and digital telecommun..

DT-TELE-RJ45

2882925

PHOENIX_CONTACT

Available

Ship on today

Attachment plug with surge protection for analog and digital telecommunications interfaces (VDSL up to 50 Mbps). Connection: RJ45 (RJ12/RJ11) and screw terminal block (COMBICON). Alternatively, can be snapped onto a DIN rail.

More details


Overvoltage Protection Over Voltage

TRABTECH Power and Signal Quality - PHOENIX CONTACT

Surge protection for information technology - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+98,97 €
2+96,08 €
4+93,74 €
6+92,57 €
8+91,95 €
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Dimensions

Height103 mm
Width25 mm
Depth63 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 85 °C
Degree of protectionIP20

General

Housing materialZinc die-cast
Colorsilver/black
Standards for cearances and creepage distancesIEC 60664-1
VDE 0110-1
Mounting typeConnection-specific attachment plug and DIN rail, 35 mm
TypeAttachment plug for DIN rail mounting
Number of positions4
Direction of actionLine-Line & Line-Ground/Shield

Protective circuit

IEC test classificationB2
C1
C2
C3
D1
VDE requirement classB2
C1
C2
C3
D1
Maximum continuous voltage UC185 V DC
130 V AC
Maximum continuous voltage UC (wire-wire)185 V DC
130 V AC
Maximum continuous voltage UC (wire-ground)185 V DC
Nominal current IN≤ 380 mA (25 °C)
Operating effective current IC at UC≤ 6 µA
Standby power consumption PC≤ 2010 mVA
Residual current IPE≤ 4 µA
Nominal discharge current In (8/20) µs (Core-Core)≤ 5 kA
Nominal discharge current In (8/20) µs (Core-Earth)≤ 5 kA
Total surge current (8/20) µs10 kA
Nominal pulse current Ian (10/1000) µs (Core-Core)100 A
Nominal pulse current Ian (10/1000) µs (Core-Earth)100 A
Nominal pulse current Ian (10/700) µs (Core-Core)150 A
Nominal pulse current Ian (10/700) µs (Core-Earth)150 A
Output voltage limitation at 1 kV/µs (Core-Core) static≤ 250 V
Output voltage limitation at 1 kV/µs (Core-Earth) static≤ 250 V
Residual voltage at In (conductor-conductor)≤ 120 V
Residual voltage at In (conductor-ground)≤ 120 V
Voltage protection level Up (core-core)≤ 250 V (B2 - 100 A)
≤ 250 V (C1 - 500 A)
≤ 250 V (C2 - 5 kA)
Voltage protection level Up (core-ground)≤ 250 V (B2 - 100 A)
≤ 250 V (C1 - 500 A)
≤ 250 V (C2 - 5 kA)
Response time tA (Core-Core)≤ 100 ns
Response time tA (Core-Earth)≤ 100 ns
Input attenuation aE, sym.typ. 0.5 dB (≤ 5 MHz)
typ. 0.3 dB (≤ 8 MHz / 150 Ω)
typ. 0.3 dB (≤ 2.5 MHz / 600 Ω)
Cut-off frequency fg (3 dB), sym. in 100 Ohm systemtyp. 50 MHz
Resistance in series3.3 Ω 10 %
Impulse durability (conductor-conductor)C1 - 1 kV/500 A
C2 - 10 kV/5 kA
B2 - 4 kV/100 A
Impulse durability (conductor-ground)B2 - 4 kV/100 A
C1 - 1 kV/500 A
C2 - 10 kV/5 kA
D1 - 1 kA

Connection data

Connection methodRJ45/Combicon
Connection type INRJ45 socket
MC 1,5/4
Connection type OUTRJ45 socket
MC 1,5/4
Connection methodScrew connection
Screw threadM2
Tightening torque0.22 Nm
Stripping length7 mm
Conductor cross section flexible min.0.14 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section solid min.0.14 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section AWG min.28
Conductor cross section AWG max.16

Connection, equipotential bonding

Connection methodCable connection/DIN rail

Standards and Regulations

Standards/regulationsIEC 61643-21

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2882925-DT-TELE-RJ45English118 KbytesPHOENIX CONTACT-2882925-DT-TELE-RJ45