C-UFB- 5DC/E 75 2763604 PHOENIX CONTACT Surge protection device View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

C-UFB- 5DC/E 75 2763604 PHOENIX CONTACT Surge protection device

C-UFB-5DC/E 75

2763604

PHOENIX_CONTACT

Product on demand only, returns will not be accepted.

Surge protection device

Adapter with coarse and fine surge protection, for coaxial signal interfaces with display without earth potential, signal voltage of 5 V, connection: Female-male BNC

More details


Earthing, lightning and surge protection > Surge protection device for data networks/MCR-technology

Trabtech (TT)

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Best sellers

More info



Key Commercial Data

Orderkey2763604
Packing unit10 pc
Catalog pagePage 177 (C-4-2017)
GTIN4017918347772
Weight per Piece (excluding packing)102.800 g
Custom tariff number85363010
Country of originDE (Germany)

Dimensions

Height25.4 mm
Width25.4 mm
Depth93 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 80 °C
Degree of protectionIP20

General

Housing materialAluminum
Colorblack
Standards for cearances and creepage distancesVDE 0110-1
IEC 60664-1
Mounting typeConnection-specific intermediate plugging
TypeAttachment plug
Direction of actionLine-Shield/Earth Ground

Protective circuit

IEC test classificationC2
C3
D1
Maximum continuous voltage UC5 V DC
Rated current185 mA (25 °C)
Operating effective current ICat UC≤ 300 µA
Residual current IPE≤ 2 µA
Nominal discharge current In(8/20) µs (line-earth)10 kA
Nominal discharge current In(8/20) µs (line-shield)10 kA
Total discharge current Itotal(8/20) µs20 kA
Output voltage limitation at 1 kV/µs (line-earth) spike≤ 500 V
Output voltage limitation at 1 kV/µs (line-shield) spike≤ 35 V
Output voltage limitation at 1 kV/µs (line-shield) static≤ 15 V
Residual voltage at In(line-shield)≤ 12 V
Voltage protection level Up(line-earth)≤ 500 V (C1 - 1 kV/500 A)
≤ 500 V (C3 - 10 A)
Voltage protection level Up(line-shield)≤ 25 V (C3 - 10 A)
≤ 55 V (C1 - 1 kV/500 A)
Response time tA(line-earth)≤ 100 ns
Response time tA (line-shield)≤ 500 ns
Input attenuation aE, asym.1.3 dB (≤ 5 MHz)
Cut-off frequency fg (3 dB), asym. (shield) in 50 Ohm systemtyp. 80 MHz
Surge protection fault messagenone
Impulse durability (line-earth)C2 - 10 kV/5 kA
D1 - 2.5 kA

Connection data

Connection methodBNC 75 Ω
Connection method INBNC socket
Connection method OUTBNC plug

Connection, equipotential bonding

Connection methodPVC litz wire

Standards and Regulations

Standards/regulationsIEC 61643-21
Standards/specificationsIEC 61643-21 2000

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications


Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.