MCR-C-I-U- 4-DC 2814511 PHOENIX CONTACT MCR 3-way isolating amplifier, for electrical isolation of analog si.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

MCR-C-I-U- 4-DC 2814511 PHOENIX CONTACT MCR 3-way isolating amplifier, for electrical isolation of analog si..

MCR-C-I-U- 4-DC

2814511

PHOENIX_CONTACT

5

Available

Ship on today

MCR 3-way isolating amplifier, for electrical isolation of analog signals, input signal: 4 mA ... 20 mA, output signal: 0 V... 10 V

More details


Programmable Logic Controllers Plcs

INTERFACE Signal converters, switching devices, and power supply units - PHOENIX CONTACT

Modular Converter MCR technique. Analog - PHOENIX CONTACT

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Dimensions

Width12.5 mm
Height99 mm
Depth114.5 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 60 °C

Input data

Description of the inputCurrent input
Configurable/programmableno
Current input signal4 mA ... 20 mA
Max. input current50 mA
Input resistance current input50 Ω

Output data

Configurable/programmableno
Voltage output signal0 V ... 10 V
Max. output voltage15 V
Load/output load voltage output≥ 10 kΩ
Linear transmission range (in reference to the output range end value)-10 % ... 110 %

Power supply

Supply voltage range20 V DC ... 30 V DC
Typical current consumption< 15 mA (without load)

Connection data

Connection methodPluggable screw connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Stripping length8 mm
Screw threadM3

General

No. of channels1
Maximum transmission error≤ 0.3 % (of final value)
Transmission error, typical< 0.2 % (of final value)
Max. scale factor error< 0.3 % (of final value)
Maximum temperature coefficient< 0.015 %/K
Limit frequency (3 dB)30 Hz
Step response (10-90%)11 ms
Protective circuitTransient protection
Test voltage, input/output/supply1.5 kV (50 Hz, 1 min.)
Colorgreen
Housing materialPolyamide PA non-reinforced
Mounting positionany
ConformanceCE-compliant

Datasheet - PDF

Title: Language: Size: Type:
PHOENIX CONTACT-2814511-MCR-C-I-U- 4-DC English 117 Kbytes PHOENIX CONTACT-2814511-MCR-C-I-U- 4-DC

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Últimas Opiniones de Nuestros Clientes

Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.