Branch terminal, nominal voltage: 1000 V, nominal current: 41 A, number of connections: 5, connection type: Push-in connection, 1st floor, Sizing section: 6 mm², cross-section: 0.5 mm² - 10 mm², Stud connection, Collective connection, mounting type: in base element, color: gray

Branch terminal block, nominal voltage: 1000 V, nominal current: 41 A, number of connections: 5, connection type: Push-in connection, 1st stage, Reference cross-section: 6 mm2, cross-section: 0.5 mm2 - 10 mm2, Bolted connection, Collective connection, Mounting type: on base, colour: grey

More details


Terminal blocks > Terminal block connector

Modular TBs

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total: $122.28
Unit price: $12.23
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Best sellers

More info



Key Commercial Data

Orderkey1017448
Packing unit10 pc
Minimum order quantity10 pc
GTIN4055626500638
Weight per Piece (excluding packing)37.700 g
Custom tariff number85369010
Country of originCN (China)

General

Number of levels1
Number of connections5
Potentials1
Nominal cross section6 mm²
Colorgray
Insulating materialPA
Flammability rating according to UL 94V0
Rated surge voltage8 kV
Overvoltage categoryIII
Insulating material groupI
Maximum power dissipation for nominal condition1.31 W
Maximum load current57 A
Maximum total current109 A (Bolt connection)
Nominal current IN41 A
Nominal voltage UN1000 V
Nominal current IN41 A
Open side panelNo
Shock protection test specificationDIN EN 50274 (VDE 0660-514):2002-11
Back of the hand protectionNot guaranteed
Finger protectionNot guaranteed
Result of surge voltage testTest passed
Surge voltage test setpoint9.8 kV
Result of power-frequency withstand voltage testTest passed
Power frequency withstand voltage setpoint2.2 kV
Result of the test for mechanical stability of terminal points (5 x conductor connection)Test passed
Result of bending testTest passed
Bending test rotation speed10 rpm
Bending test turns135
Bending test conductor cross section/weight0.5 mm² / 0.3 kg
6 mm2/ 1.4 kg
10 mm² / 2 kg
Tensile test resultTest passed
Conductor cross section tensile test0.5 mm²
Tractive force setpoint20 N
Conductor cross section tensile test6 mm²
Tractive force setpoint80 N
Conductor cross section tensile test10 mm²
Tractive force setpoint90 N
Result of tight fit on supportTest passed
Tight fit on carrierNS 35
Setpoint5 N
Result of voltage-drop testTest passed
Requirements, voltage drop≤ 3.2 mV
Result of temperature-rise testTest passed
Short circuit stability resultTest passed
Conductor cross section short circuit testing6 mm²
Short-time current0.72 kA
Conductor cross section short circuit testing10 mm²
Short-time current1.2 kA
Result of thermal testTest passed
Ageing test for screwless modular terminal block temperature cycles192
Proof of thermal characteristics (needle flame) effective duration30 s
Result of aging testTest passed
Oscillation, broadband noise test resultTest passed
Test specification, oscillation, broadband noiseDIN EN 50155 (VDE 0115-200):2008-03
Test spectrumService life test category 2, bogie-mounted
Test frequencyf1= 5 Hz to f2= 250 Hz
ASD level6.12 (m/s2)2/Hz
Acceleration3.12 g
Test duration per axis5 h
Test directionsX-, Y- and Z-axis
Shock test resultTest passed
Test specification, shock testDIN EN 50155 (VDE 0115-200):2008-03
Shock formHalf-sine
Acceleration30g
Shock duration18 ms
Number of shocks per direction3
Test directionsX-, Y- and Z-axis (pos. and neg.)
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))130 °C
Static insulating material application in cold-60 °C
Behavior in fire for rail vehicles (DIN 5510-2)Test passed
Flame test method (DIN EN 60695-11-10)V0
Oxygen index (DIN EN ISO 4589-2)>32 %
NF F16-101, NF F10-102 Class I2
NF F16-101, NF F10-102 Class F2
Surface flammability NFPA 130 (ASTM E 162)passed
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Smoke gas toxicity NFPA 130 (SMP 800C)passed
Calorimetric heat release NFPA 130 (ASTM E 1354)28 MJ/kg
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

Dimensions

Width31 mm
Length57.4 mm
Height32.3 mm
Hole diameter10.4 mm

Connection data

Feed-in connection1 level
Connection methodPush-in connection
Connection in acc. with standardIEC 60947-7-1
Conductor cross section solid min.0.5 mm²
Conductor cross section solid max.10 mm²
Conductor cross section AWG min.20
Conductor cross section AWG max.8
Conductor cross section flexible min.0.5 mm²
Conductor cross section flexible max.6 mm²
Min. AWG conductor cross section, flexible20
Max. AWG conductor cross section, flexible10
Conductor cross section flexible, with ferrule without plastic sleeve min.0.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.6 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min.0.5 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.6 mm²
Stripping length10 mm ... 12 mm
Internal cylindrical gageA5
NoteConnection bolts
Connection methodBolt connection
Connection in acc. with standardIEC 60947-7-1
Conductor cross section flexible min.6 mm²
Conductor cross section flexible max.120 mm²
Min. AWG conductor cross section, flexible10
Max. AWG conductor cross section, flexible250 kcmil
Hole diameter, min.10.4 mm
Cable lug width, max.32 mm
Bolt diameter10 mm
Screw threadM10
M10
Tightening torque, min10 Nm
Tightening torque max20 Nm

Standards and Regulations

Connection in acc. with standardIEC 60947-7-1
IEC 60947-7-1
Flammability rating according to UL 94V0
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications


ETIM for 1017448 Terminal blocks (EC000897)
Feature Name Feature Value
Connectable conductor cross section fine-strand without cable end sleeve (EF007341) 0.5 mm²
Connectable conductor cross section fine-strand with cable end sleeve (EF007339) 0.5 mm²
Connectable conductor cross section solid-core (EF007337) 0.5 mm²
Rated current In (EF008250) 41 A
Rated voltage (EF000228) 1000 V
Type of electrical connection 1 (EF002526) Other
Type of electrical connection 2 (EF002527) Other
Number of clamp positions per level (EF002660) 5
Suitable for conductor material (EF012572) Aluminium/copper
Material insulation body (EF007543) Other
Inflammability class of insulation material according to UL94 (EF002521) V0
Width (EF000008) 31.05 mm
Height (EF000040) 57.546666 mm
Depth (EF000049) 35.63009 mm
Closing plate required (EF002525) No
Colour (EF000007) Grey
Internally connected stages (EF002661) Yes

Datasheet - PDF

Title: Size: Type:
PDF CATALOG PHOENIX TERMINAL BLOCKS EN.pdf 69 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.