PLC-OSP-110DC/110DC/ 3RW 2982566 PHOENIX CONTACT Solid-state relay module View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

PLC-OSP-110DC/110DC/ 3RW 2982566 PHOENIX CONTACT Solid-state relay module

PLC-OSP-110DC/110DC/ 3RW

2982566

PHOENIX_CONTACT

Solid-state relay module

More details


INTERFACE Components (IF)

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Key Commercial Data

Orderkey2982566
Packing unit10 pc
NoteMade to Order (non-returnable)
Catalog pagePage 415 (C-5-2017)
GTIN4046356082488
Weight per Piece (excluding packing)33.490 g
Custom tariff number85364900
Country of originDE (Germany)

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Dimensions

Width6.2 mm
Height80 mm
Depth86 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 70 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Degree of protectionIP20

Input data

Nominal input voltage UN110 V DC
Input voltage range in reference to UN0.7 ... 1.25 (t < 1 s = 0.6 ... 1.4 x UN)
Input voltage range77 V DC ... 137.5 V DC
Switching threshold "0" signal in reference to UN< 0.3
Switching threshold "1" signal in reference to UN> 0.6
Typical input current at UN5.5 mA
Typical response time400 µs
Typical turn-off time200 µs
Operating voltage displayYellow LED
Type of protectionReverse polarity protection
Surge protection
Protective circuit/componentSeries polarity protection diode
Surge voltage protection> 150 V
Transmission frequency300 Hz
Power dissipation for nominal condition0.61 W

Output data

Output nominal voltage110 V DC
Output voltage range12 V DC ... 140 V DC (t < 1 s = 1.40 x UN)
Limiting continuous current3 A (see derating curve)
Surge voltage protection> 150 V
Voltage drop at max. limiting continuous current< 150 mV
Output circuit2-wire, floating
Type of protectionReverse polarity protection
Surge protection
Protective circuit/componentParallel polarity protection diode

Connection data, input side

Connection nameInput side
Connection methodSpring-cage connection
Stripping length8 mm
Conductor cross section solid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Conductor cross section AWG26 ... 14

Connection data, output side

Connection nameOutput side
Connection methodSpring-cage connection
Stripping length8 mm
Conductor cross section solid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Conductor cross section AWG26 ... 14

General

Test voltage input/output2.5 kVrms
Mounting positionany
Assembly instructionsIn rows with zero spacing
Operating mode100% operating factor
DesignationAir clearances and creepage distances between the power circuits
Standards/regulationsIEC 60664
EN 50178
Degree of pollution2
Overvoltage categoryIII

Standards and Regulations

Connection in acc. with standardCUL
DesignationAir clearances and creepage distances between the power circuits
Standards/regulationsIEC 60664
EN 50178
Rated insulation voltage160 V DC
Rated surge voltage4 kV
InsulationBasic insulation
Degree of pollution2
Overvoltage categoryIII

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.