Product successfully added to your shopping cart
RAD-2400-IFS
2901541
PHOENIX_CONTACT
1
2400 MHz wireless transceiver with RS-232, RS-485 2-wire interface, expandable with I/O extension modules, with screw connection, antenna connection:RSMA (female), including DIN rail connector, without antenna
Safety
* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Radioline is the new wireless system for large systems. Special features include extremely easy assignment of inputs and outputs by simply turning the thumbwheel - without any programming. Radioline transmits I/O signals (I/O mode) or serial data (serial mode) and is therefore very versatile. Alternatively, I/O signals can now also be connected to controllers directly using the Modbus protocol (PLC/Modbus RTU mode).
In addition, you can implement various network structures: from a simple point-to-point connection to complex mesh networks. Thanks to the latest Trusted Wireless technology, Radioline is the ideal choice for industrial use.
Width | 17.5 mm |
---|---|
Height | 99 mm |
Depth | 114.5 mm |
Degree of protection | IP20 |
---|---|
Ambient temperature (operation) | -40 °C ... 70 °C (>55°C derating) |
-40 °F ... 158 °F (>131°F derating) | |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
-40 °F ... 185 °F | |
Permissible humidity (operation) | 20 % ... 85 % |
Permissible humidity (storage/transport) | 20 % ... 85 % |
Altitude | 2000 m |
Vibration (operation) | in accordance with IEC 60068-2-6: 5g, 10 Hz ... 150 Hz |
Shock | 16g, 11 ms |
Operating mode | I/O data (Default setting, configuration via thumbwheel) |
---|---|
Serial data (Activation and configuration via PSI-CONF software) | |
PLC/Modbus RTU mode (Activation and configuration via PSI-CONF software) | |
Overvoltage category | II |
Assembly instructions | on standard DIN rail NS 35 in accordance with EN 60715 |
Pollution degree | 2 |
Housing material | PA 6.6-FR |
Flammability rating according to UL 94 | V0 |
MTTF | 778 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) |
358 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day)) | |
142 Years (Telcordia standard, temperature 40 °C, operating cycle 100 % (7 days a week, 24 hours a day)) | |
Wireless licences | Australia |
Belgium | |
Bulgaria | |
Denmark | |
Germany | |
Estonia | |
France | |
Finland | |
Greece | |
Great Britain | |
Italy | |
Ireland | |
Iceland | |
Canada | |
Croatia | |
Liechtenstein | |
Luxembourg | |
Latvia | |
Lithuania | |
Malta | |
Morocco | |
Netherlands | |
Norway (The device may not be operated within 20 km of Ny Ålesund town center.) | |
Austria | |
Poland | |
Portugal | |
Romania | |
Russia | |
Sweden | |
Switzerland | |
Slovakia | |
Slovenia | |
Singapore | |
Spain | |
South Africa | |
Thailand | |
Czech Republic | |
Turkey (The device may only be operated with Phoenix Contact antennas in accordance with the “Short Range Radio Devices (SRD) Regulations” Gazette No. 26464 dated March 16, 2007.) | |
Hungary | |
USA | |
Ukraine | |
United Arab Emirates | |
Cyprus (rep.) | |
Export note | *The range may be considerably above or below that stated. It is dependent on the environment, antenna technology, transmission power, and the product used. |
Supply voltage range | 19.2 V DC ... 30.5 V DC |
---|---|
Max. current consumption | ≤ 65 mA (@ 24 V DC, @ 25°C, stand-alone) |
Transient surge protection | Yes |
Antenna connection | RSMA (female) |
---|---|
Direction | Bi-directional |
Frequency | 2400 MHz |
Frequency range | 2.4002 GHz ... 2.4785 GHz |
Number of channel groups | 8 |
Number of channels per group | 55 |
Channel distance | 1.3 MHz |
Data rate | 16 kbps (adjustable) |
125 kbps (Default setting, adjustable) | |
250 kbps (adjustable) | |
Receiver sensitivity | -106 dBm (16 kbps) |
-96 dBm (125 kbps) | |
-93 dBm (250 kbps) | |
Transmit capacity, minimum | 0 dBm |
Transmit capacity, maximum | ≤ 20 dBm (Outside of Europe, adjustable via software) |
≤ 19 dBm (Europe, can be set via software, depends on the data rate) | |
18 dBm (Default setting, adjustable) | |
Range | ± 5 km (The range may be considerably above or below that stated, and depends on the environment, antenna technology, and the product used) |
Security | 128-bit data encryption |
Interface 1 | RS-232 |
---|---|
Connection method | COMBICON plug-in screw terminal block |
3-conductor | |
Transmission length | ≤ 15 m |
Transmission speed | 0,3 ... 115,2 kbit/s |
Interface 2 | RS-485 |
Connection method | COMBICON plug-in screw terminal block |
2-wire | |
Transmission length | ≤ 1200 m |
Termination resistor | 390 Ω (switchable via DIP switches) |
150 Ω (switchable via DIP switches) | |
390 Ω (switchable via DIP switches) | |
Transmission speed | 0,3 ... 187,5 kbit/s |
Interface 3 | Configuration interface |
Connection method | S-PORT (socket) |
Designation | Wireless module |
---|---|
Number of supported devices | ≤ 250 (Addressing via PSI-CONF software) |
≤ 99 (Addressing via thumbwheel) | |
Number of possible extension modules | ≤ 32 (per wireless module) |
Designation | Wireless network |
I/O data mode | ≤ 99 (I/O extension modules per wireless network, serial interfaces deactivated) |
Serial data mode | 0 (no I/O extension modules can be used) |
PLC/Modbus RTU mode | ≤ 99 (I/O extension modules per wireless network, access to extension modules via Modbus RTU protocol) |
Number of outputs | 1 |
---|---|
Voltage output signal | 0 V ... 3 V |
Number of outputs | 1 |
---|---|
Contact type | PDT |
Contact material | PdRu, gold-plated |
Maximum switching voltage | 30 V AC/DC |
60 V DC | |
Max. switching current | 500 mA (30 V AC/DC) |
Electrical service life | 5 x 105cycles with 0.5 A @ 30 V DC |
Connection method | Screw connection |
---|---|
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 14 |
Stripping length | 7 mm |
Tightening torque | 0.6 Nm |
Screw thread | M3 |
Status display | Green LED (supply voltage, PWR) |
---|---|
Green LED (bus communication, DAT) | |
Red LED (periphery error, ERR) | |
3 x green, 1 x yellow LED (LED bar graph receive quality, RSSI) | |
Green LED (receive data, RX) | |
Green LED (transmit data, TX) |
Conformance | CE compliance (R&TTE directive 1999/5/EC) |
---|---|
IECEx | Ex nA nC IIC T4 Gc |
UL, USA / Canada | UL 508 Listed |
Standard designation | Ex Directive (ATEX) |
Standards/regulations | EN 60079-0 |
Standard designation | Ex Directive (ATEX) |
Standards/regulations | EN-60079-15 |
Standard designation | R&TTE Directive 1999/5/EC |
Standards/regulations | EN 300328 |
EN 61000-6-4 | |
EN 61000-6-2 | |
EN 50371 | |
EN 60950-1 |
Title: | Size: | Type: |
---|---|---|
PDF CATALOG PHOENIX AUTOMATION EN.pdf | 35 Mbytes | |
PHOENIX CONTACT-2901541-RAD-2400-IFS | 2 Mbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.