RAD-2400-IFS 2901541 PHOENIX CONTACT 2400 MHz wireless transceiver with RS-232, RS-485 2-wire interface, exp.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

RAD-2400-IFS 2901541 PHOENIX CONTACT 2400 MHz wireless transceiver with RS-232, RS-485 2-wire interface, exp..

RAD-2400-IFS

2901541

PHOENIX_CONTACT

2400 MHz wireless transceiver with RS-232, RS-485 2-wire interface, expandable with I/O extension modules, with screw connection, antenna connection:RSMA (female), including DIN rail connector, without antenna

More details


Safety

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total price: $854.39
Unit price: $854.39

Quantity Price
1+$854.39
2+$854.39
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Often bought together

More info



Product description

Radioline is the new wireless system for large systems. Special features include extremely easy assignment of inputs and outputs by simply turning the thumbwheel - without any programming. Radioline transmits I/O signals (I/O mode) or serial data (serial mode) and is therefore very versatile. Alternatively, I/O signals can now also be connected to controllers directly using the Modbus protocol (PLC/Modbus RTU mode).

In addition, you can implement various network structures: from a simple point-to-point connection to complex mesh networks. Thanks to the latest Trusted Wireless technology, Radioline is the ideal choice for industrial use.

Dimensions

Width17.5 mm
Height99 mm
Depth114.5 mm

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)-40 °C ... 70 °C (>55°C derating)
-40 °F ... 158 °F (>131°F derating)
Ambient temperature (storage/transport)-40 °C ... 85 °C
-40 °F ... 185 °F
Permissible humidity (operation)20 % ... 85 %
Permissible humidity (storage/transport)20 % ... 85 %
Altitude2000 m
Vibration (operation)in accordance with IEC 60068-2-6: 5g, 10 Hz ... 150 Hz
Shock16g, 11 ms

General

Operating modeI/O data (Default setting, configuration via thumbwheel)
Serial data (Activation and configuration via PSI-CONF software)
PLC/Modbus RTU mode (Activation and configuration via PSI-CONF software)
Overvoltage categoryII
Assembly instructionson standard DIN rail NS 35 in accordance with EN 60715
Pollution degree2
Housing materialPA 6.6-FR
Flammability rating according to UL 94V0
MTTF778 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day))
358 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day))
142 Years (Telcordia standard, temperature 40 °C, operating cycle 100 % (7 days a week, 24 hours a day))
Wireless licencesAustralia
Belgium
Bulgaria
Denmark
Germany
Estonia
France
Finland
Greece
Great Britain
Italy
Ireland
Iceland
Canada
Croatia
Liechtenstein
Luxembourg
Latvia
Lithuania
Malta
Morocco
Netherlands
Norway (The device may not be operated within 20 km of Ny Ålesund town center.)
Austria
Poland
Portugal
Romania
Russia
Sweden
Switzerland
Slovakia
Slovenia
Singapore
Spain
South Africa
Thailand
Czech Republic
Turkey (The device may only be operated with Phoenix Contact antennas in accordance with the “Short Range Radio Devices (SRD) Regulations” Gazette No. 26464 dated March 16, 2007.)
Hungary
USA
Ukraine
United Arab Emirates
Cyprus (rep.)
Export note*The range may be considerably above or below that stated. It is dependent on the environment, antenna technology, transmission power, and the product used.

Supply

Supply voltage range19.2 V DC ... 30.5 V DC
Max. current consumption≤ 65 mA (@ 24 V DC, @ 25°C, stand-alone)
Transient surge protectionYes

Wireless interface

Antenna connectionRSMA (female)
DirectionBi-directional
Frequency2400 MHz
Frequency range2.4002 GHz ... 2.4785 GHz
Number of channel groups8
Number of channels per group55
Channel distance1.3 MHz
Data rate16 kbps (adjustable)
125 kbps (Default setting, adjustable)
250 kbps (adjustable)
Receiver sensitivity-106 dBm (16 kbps)
-96 dBm (125 kbps)
-93 dBm (250 kbps)
Transmit capacity, minimum0 dBm
Transmit capacity, maximum≤ 20 dBm (Outside of Europe, adjustable via software)
≤ 19 dBm (Europe, can be set via software, depends on the data rate)
18 dBm (Default setting, adjustable)
Range± 5 km (The range may be considerably above or below that stated, and depends on the environment, antenna technology, and the product used)
Security128-bit data encryption

Serial interface

Interface 1RS-232
Connection methodCOMBICON plug-in screw terminal block
3-conductor
Transmission length≤ 15 m
Transmission speed0,3 ... 115,2 kbit/s
Interface 2RS-485
Connection methodCOMBICON plug-in screw terminal block
2-wire
Transmission length≤ 1200 m
Termination resistor390 Ω (switchable via DIP switches)
150 Ω (switchable via DIP switches)
390 Ω (switchable via DIP switches)
Transmission speed0,3 ... 187,5 kbit/s
Interface 3Configuration interface
Connection methodS-PORT (socket)

System limits

DesignationWireless module
Number of supported devices≤ 250 (Addressing via PSI-CONF software)
≤ 99 (Addressing via thumbwheel)
Number of possible extension modules≤ 32 (per wireless module)
DesignationWireless network
I/O data mode≤ 99 (I/O extension modules per wireless network, serial interfaces deactivated)
Serial data mode0 (no I/O extension modules can be used)
PLC/Modbus RTU mode≤ 99 (I/O extension modules per wireless network, access to extension modules via Modbus RTU protocol)

RSSI output

Number of outputs1
Voltage output signal0 V ... 3 V

RF link relay output

Number of outputs1
Contact typePDT
Contact materialPdRu, gold-plated
Maximum switching voltage30 V AC/DC
60 V DC
Max. switching current500 mA (30 V AC/DC)
Electrical service life5 x 105cycles with 0.5 A @ 30 V DC

Connection data

Connection methodScrew connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Stripping length7 mm
Tightening torque0.6 Nm
Screw threadM3

Status indicator

Status displayGreen LED (supply voltage, PWR)
Green LED (bus communication, DAT)
Red LED (periphery error, ERR)
3 x green, 1 x yellow LED (LED bar graph receive quality, RSSI)
Green LED (receive data, RX)
Green LED (transmit data, TX)

Approvals and conformance

ConformanceCE compliance (R&TTE directive 1999/5/EC)
IECExEx nA nC IIC T4 Gc
UL, USA / CanadaUL 508 Listed
Standard designationEx Directive (ATEX)
Standards/regulationsEN 60079-0
Standard designationEx Directive (ATEX)
Standards/regulationsEN-60079-15
Standard designationR&TTE Directive 1999/5/EC
Standards/regulationsEN 300328
EN 61000-6-4
EN 61000-6-2
EN 50371
EN 60950-1

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.