AXL F SSI1 AO1 1H
2688433
PHOENIX_CONTACT
1
Special function module
AxiolineF special function module, 1SSI interface for absolute value transmitter, 1 analog output: 0-10V, ±10V, 0-5V, ±5V, 0-20mA, 4-20mA, ±20mA, 2-conductor connection technology (including bus base and plugs)
PLC's > Fieldbus, decentr. periphery - function-/technology module
I/O
Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Orderkey | 2688433 |
|---|---|
| Packing unit | 1 pc |
| Note | Made to Order (non-returnable) |
| Catalog page | Page 122 (C-6-2017) |
| GTIN | 4046356644952 |
| Weight per Piece (excluding packing) | 135.000 g |
| Custom tariff number | 85389091 |
| Country of origin | DE (Germany) |
| Dimensional drawing | |
|---|---|
| Width | 35 mm |
| Height | 126.1 mm |
| Depth | 54 mm |
| Note on dimensions | The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715). |
| Ambient temperature (operation) | -25 °C ... 60 °C |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
| Permissible humidity (storage/transport) | 5 % ... 95 % (non-condensing) |
| Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Degree of protection | IP20 |
| Designation | Axioline F connector |
|---|---|
| Connection method | Push-in connection |
| Note on the connection method | Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual. |
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 1.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 1.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 16 |
| Stripping length | 8 mm |
| Mounting type | DIN rail |
|---|---|
| Net weight | 135 g |
| Note on weight specifications | with connectors and bus base module |
| Designation | Axioline F local bus |
|---|---|
| No. of channels | 2 |
| Connection method | Bus base module |
| Transmission speed | 100 Mbps |
| Designation | Axioline F local bus supply (UBus) |
|---|---|
| Supply voltage | 5 V DC (via bus base module) |
| Current consumption | max. 140 mA |
| Power consumption | max. 0.7 W |
| Designation | Supply voltage input UI |
| Supply voltage | 24 V DC |
| Supply voltage range | 19.2 V DC ... 30 V DC including all tolerances, including ripple |
| Current consumption | max. 60 mA (Supply of the SSI interface and the analog output (20 mA), without sensor supply) |
| Power consumption | max. 1.4 W (Supply of the SSI interface and the analog output (20 mA), without sensor supply) |
| Type of protection | Surge protection of the supply voltage |
| Polarity reversal protection of the supply voltage | |
| Transient protection |
| Input name | SSI interface |
|---|---|
| Description of the input | RS-422 interface according to SSI specification |
| Number of inputs | 1 |
| Connection method | Push-in connection |
| Encoder signals | Single-turn and multi-turn encoder, length measuring sticks |
| Input frequency | to 2 MHz (Can be parameterized: 67.5 kHz, 125 kHz (default), 250 kHz, 500 kHz, 1 MHz, 2 MHz) |
| Parity | Even, odd or no parity |
| Transmission frequency | 2 MHz |
| Adjustable resolution | 8 ... 56 bit |
| Encoder supply voltage | 24 V DC (UI- 0.5 V) |
| Nominal output voltage | 24 V DC (UI- 0.5 V) |
|---|---|
| Voltage range | 19.5 V DC ... 30 V DC (including all tolerances, including ripple) |
| Current carrying capacity | max. 500 mA |
| Type of protection | Surge protection |
| Short-circuit/overload protection | |
| Transient protection |
| Number of outputs | 1 |
|---|---|
| Connection method | Push-in connection |
| Connection technology | 2-wire (shielded, twisted pair) |
| Output name | Analog outputs |
| D/A conversion time | 5 µs |
| D/A resolution | 16 bit |
| Type of protection | Surge protection |
| Short-circuit and overload protection | |
| Transient protection | |
| Protective circuit/component | Electronic (35 V, permanent) |
| Electronic | |
| Suppressor diode | |
| Data formats | IB IL, S7-compatible, standardized representation |
| Measured value representation | 16 bits |
| Representation of output values | 16 bits (15 bits + sign) |
| Current output signal | 0 mA ... 20 mA |
| 4 mA ... 20 mA | |
| -20 mA ... 20 mA | |
| Load/output load current output | max. 500 Ω |
| Voltage output signal | 0 V ... 5 V |
| -5 V ... 5 V | |
| 0 V ... 10 V | |
| -10 V ... 10 V | |
| Load/output load voltage output | > 2 kΩ |
| Precision | typ. 0.1 % (of output range final value) |
| Permissible cable length | max. 250 m |
| Test section | Logic 500 V AC 50 Hz 1 min. |
|---|---|
| SSI I/O (24 V supply) 500 V AC 50 Hz 1 min. | |
| Functional earth ground 500 V AC 50 Hz 1 min. | |
| Analog I/O 500 V AC 50 Hz 1 min. |
| Mechanical tests | Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g |
|---|---|
| Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30g | |
| Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g | |
| Protection class | III, IEC 61140, EN 61140, VDE 0140-1 |
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
| No hazardous substances above threshold values |
| Feature Name | Feature Value |
|---|---|
| Supply voltage DC (EF007534) | 19.2 V |
| Number of functions (EF003244) | 2 |
| Number of HW-interfaces industrial Ethernet (EF003020) | 0 |
| Number of interfaces PROFINET (EF006932) | 0 |
| Number of HW-interfaces RS-232 (EF003021) | 0 |
| Number of HW-interfaces RS-422 (EF003022) | 0 |
| Number of HW-interfaces RS-485 (EF003023) | 0 |
| Number of HW-interfaces serial TTY (EF003024) | 0 |
| Number of HW-interfaces parallel (EF003026) | 0 |
| Number of HW-interfaces wireless (EF006933) | 0 |
| Number of HW-interfaces USB (EF003025) | 0 |
| Number of HW-interfaces other (EF003027) | 0 |
| With optical interface (EF003028) | No |
| Supporting protocol for EtherCAT (EF017564) | No |
| Supporting protocol for TCP/IP (EF003050) | No |
| Supporting protocol for PROFIBUS (EF003052) | Yes |
| Supporting protocol for CAN (EF003053) | No |
| Supporting protocol for INTERBUS (EF003054) | No |
| Supporting protocol for ASI (EF003051) | No |
| Supporting protocol for KNX (EF003055) | No |
| Supporting protocol for Modbus (EF003057) | No |
| Supporting protocol for Data-Highway (EF003058) | No |
| Supporting protocol for DeviceNet (EF003059) | No |
| Supporting protocol for SUCONET (EF003060) | No |
| Supporting protocol for LON (EF003017) | No |
| Supporting protocol for PROFINET IO (EF007525) | No |
| Supporting protocol for PROFINET CBA (EF007524) | No |
| Supporting protocol for SERCOS (EF006657) | No |
| Supporting protocol for Foundation Fieldbus (EF007522) | No |
| Supporting protocol for EtherNet/IP (EF007521) | No |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | No |
| Supporting protocol for DeviceNet Safety (EF007520) | No |
| Supporting protocol for INTERBUS-Safety (EF006662) | No |
| Supporting protocol for PROFIsafe (EF007526) | No |
| Supporting protocol for SafetyBUS p (EF007527) | No |
| Supporting protocol for other bus systems (EF003062) | No |
| IO link master (EF007298) | No |
| System accessory (EF004118) | Yes |
| Function block restart blockage (EF007212) | No |
| Function block automatic reset (EF007208) | No |
| Contactor control function block (EF007467) | No |
| Function block emergency stop (EF007211) | No |
| Function block contactless working protection installation (EF007209) | No |
| Function block affirm push button (EF007214) | No |
| Function block 2-hand switching (EF007215) | No |
| Function block operating mode selection (EF007210) | No |
| Function block access control (EF007213) | No |
| Degree of protection (IP) (EF005474) | IP20 |
| Fieldbus connection over separate bus coupler possible (EF004002) | Yes |
| Frequency measurement (EF000599) | Yes |
| Suitable for rail mounting (EF003972) | Yes |
| Wall mounting/direct mounting (EF007020) | No |
| Front built-in possible (EF007016) | No |
| Rack-assembly possible (EF007018) | No |
| Suitable for safety functions (EF001597) | No |
| SIL according to IEC 61508 (EF009889) | None |
| Performance level according to EN ISO 13849-1 (EF007399) | None |
| Appendant operation agent (Ex ia) (EF004141) | No |
| Appendant operation agent (Ex ib) (EF004142) | No |
| Explosion safety category for gas (EF003997) | None |
| Explosion safety category for dust (EF003998) | None |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG PHOENIX AUTOMATION EN.pdf | 35 Mbytes |
|
| PHOENIX CONTACT-2688433-AXL F SSI1 AO1 1H | 164 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.