PHOENIX CONTACT  ELR 3-230AC/500AC- 2 2297206 - Image 1

Images are for illustrative purposes only. Please refer to data sheet for details.

ELR 3-230AC/500AC- 2 2297206 PHOENIX CONTACT Solid-state contactor

Reference: ELR 3-230AC/500AC- 2

Code: 2297206

Manufacturer: PHOENIX CONTACT

Description:

Solid-state contactor
Three-phase semiconductor contactor with 230 V AC input, 2 A output current, zero voltage switch, optionally with thermal fuse
Three-phase solid-state contactor with 230 V AC input, 2 A output current, zero voltage switch, optionally with thermal fuse

Categories:

  • PHOENIX CONTACT > INTERFACE Components (IF)

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX CONTACT

  • More Info
  • PDF
  • Reviews
Guarantee, repair and return.

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

MORE INFO

Technical data

Product properties
Product typeSolid-state contactor
Operating mode100% operating factor
Data management status
Article revision05

Electrical properties
Number of phases3
Switching frequency≤ 1 Hz
Test voltage (Input/output)5 kVrms(50 Hz, 60 s)
Switching frequency≤ 1 Hz
Insulation characteristics
Rated insulation voltage500 V
Rated surge voltage6 kV
Overvoltage categoryIII
Degree of pollution2
Insulation characteristics between the control input voltage to the main circuitBasic insulation

Input data
Control
Input nameControl input right/left
Mains frequency50 Hz
60 Hz
Rated actuating voltage UC230 V AC
Triggering voltage range92 V AC ... 253 V AC
Voltage range with reference to UC0.4 ... 1.1
0.4 ... 1.1
Rated actuating current IC12.5 mA
Switching threshold48 V AC (“0” signal)
96 V AC (“1” signal)
Protective circuitSurge protection; Varistor
Error indicationRed LED
Status displayLED (yellow)

Output data
AC output
Rated operating voltage Ue500 V AC
Operating voltage range48 V AC ... 575 V AC
Rated operating current at AC-512 A
Rated operating current at AC-53a2 A
Peak offstate voltage1200 V
Mains frequency40 Hz ... 100 Hz
Load current range100 mA ... 2 A (see to derating)
Leakage current6 mA
Residual voltage< 1.5 V
Surge current200 A (t = 10 ms)
Max. load value250 A2s
Protective circuitRCV circuit
Surge voltage protection> 575 V AC

Connection data
Control circuits
Connection methodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 14
Tightening torque0.5 Nm ... 0.6 Nm
5 lbf-in. ... 7 lbf-in.
Load circuit
Connection methodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 14
Tightening torque0.5 Nm ... 0.6 Nm
5 lbf-in. ... 7 lbf-in.

Signaling
Status displayLED (yellow)
Error indicationRed LED

Dimensions
Width40 mm
Height99 mm
Depth114.5 mm

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP20
Ambient temperature (operation)-25 °C ... 70 °C
Ambient temperature (storage/transport)-25 °C ... 70 °C

Approvals
UL approval
CertificateNMFT.E323771
NRNT.E172140
UL data
SCCR5 kA (20 A RK5 (standard fault) fuse)
FLA2 A (at 500 V, AC Resistance)
2 A (at 500 V, AC General USE)
2 A (at 500 V, AC Resistance Air Heating)

Standards and regulations
Standards/regulations
Standards/regulationsDIN EN 50178
EN 60947

Mounting
Mounting typeDIN rail mounting
Assembly noteCan be aligned with spacing = 20 mm
Mounting positionVertical (horizontal DIN rail)

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.