| Product type | Device protection |
| Product family | MAINTRAB |
| IEC test classification | C1 |
| C2 | |
| C3 | |
| D1 | |
| Type | Attachment plug |
| For country-specific use in | D, A, NL, E, S, FIN, TR |
| Surge protection fault message | optical |
| Insulation characteristics | |
| Overvoltage category | III |
| Pollution degree | 2 |
| EN type | T3 |
| Number of ports | One |
| Connection method | RJ45 |
| Connection method | Grounding plug/socket |
| Dimensional drawing | ![]() |
| Width | 63 mm |
| Height | 103 mm |
| Depth | 78 mm |
| Flammability rating according to UL 94 | V-0 |
| CTI value of material | 400 |
| 600 | |
| Insulating material | PA 6 |
| Housing material | PA 6 |
| Power supplies | |
| Direction of action | L/N-PE & Signal Line-Earth Ground |
| Nominal voltage UN | 230/400 V AC (TN) |
| 230/400 V AC (TT - only in use with RCD) | |
| Nominal frequency fN | 50 Hz (60 Hz) |
| Maximum continuous operating voltage UC(L-N) | 275 V AC |
| Maximum continuous operating voltage UC(L-PE) | 360 V AC |
| Maximum continuous operating voltage UC(N-PE) | 360 V AC |
| Rated load current IL | 16 A (30 °C) |
| Residual current IPE | ≤ 5 µA |
| Standby power consumption PC | ≤ 1 VA |
| Reference test voltage UREF | 255 V AC |
| Nominal discharge current In(8/20) µs | 3 kA (> 5x) |
| Combination wave UOC | 4 kV |
| Voltage protection level Up(L-N) | ≤ 1.2 kV |
| Voltage protection level Up(L-PE) | ≤ 1.5 kV |
| Voltage protection level Up(N-PE) | ≤ 1.5 kV |
| Residual voltage at Iamax, (L-N) | ≤ 1 kV (at 1 kA) |
| ≤ 1.2 kV (at UOC) | |
| Residual voltage at Iamax, (L-PE) | ≤ 1 kV (at 1 kA) |
| ≤ 1.5 kV (at UOC) | |
| Residual voltage at Iamax, (PE) | ≤ 1 kV (at 1 kA) |
| ≤ 1.5 kV (at UOC) | |
| TOV behavior at UT(L-N) | 335 V AC (5 s / withstand mode) |
| 440 V AC (120 min / safe failure mode) | |
| TOV behavior at UT(L-PE) | 440 V AC (5 s / withstand mode) |
| 440 V AC (120 min / withstand mode) | |
| 1455 V AC (200 ms / safe failure mode) | |
| TOV behavior at UT(N-PE) | 1200 V AC (200 ms / safe failure mode) |
| Response time tA(L-N) | ≤ 25 ns |
| Response time tA(L-PE) | ≤ 100 ns |
| Response time tA(N-PE) | ≤ 100 ns |
| Max. required back-up fuse | 16 A (gG / B / C) |
| Short-circuit current rating ISCCR | 1.5 kA AC |
| Max. backup fuse with branch wiring | 16 A (gG / B / C) |
| Information technology | |
| Maximum continuous voltage UC | 6 V DC |
| Rated current | 1.5 A (25 °C) |
| Operating effective current ICat UC | 500 µA |
| Standby power consumption PC | ≤ 1 VA |
| Residual current IPE | ≤ 4 µA |
| Insulation resistance Riso | ≥ 20 kΩ |
| ≤ 1000 MΩ | |
| Nominal discharge current In(8/20) µs (line-line) | 650 A |
| Nominal discharge current In(8/20) µs (line-ground) | 2.5 kA |
| Total discharge current Itotal(8/20) µs | 10 kA |
| Nominal pulse current Ian (10/1000) µs (line-line) | 120 A |
| Nominal pulse current Ian (10/1000) µs (line-earth) | 200 A |
| Output voltage limitation at 1 kV/µs (line-earth) spike | ≤ 900 V |
| Output voltage limitation at 1 kV/µs (line-line) static | ≤ 10 V |
| Output voltage limitation at 1 kV/µs (line-earth) static | ≤ 900 V |
| Residual voltage at In(conductor-conductor) | ≤ 20 V |
| Residual voltage at In(conductor-ground) | ≤ 50 V |
| Voltage protection level Up(line-line) | ≤ 65 V (C1 - 1 kV / 500 A) |
| Voltage protection level Up(line-earth) | ≤ 900 V (C2 - 4 kV / 2 kA) |
| Response time tA(line-line) | ≤ 1 ns |
| Response time tA(line-earth) | ≤ 100 ns |
| Cut-off frequency fg (3 dB), sym. in 100 Ω system | typ. 300 kHz |
| Capacity (Core-Core) | typ. 6 nF |
| Capacity (Core-Earth) | typ. 5 pF |
| Alternating current carrying capacity (line-line) | 1 A - 1 s |
| Alternating current carrying capacity (line-earth) | 10 A - 1 s |
| Pulse reset time (line-line) | ≤ 1 ms |
| Ambient conditions | |
| Degree of protection | IP20 (Child-proofing) |
| Ambient temperature (operation) | -25 °C ... 75 °C |
| Ambient temperature (storage/transport) | -25 °C ... 75 °C |
| Altitude | ≤ 2000 m (amsl) |
| Permissible humidity (operation) | 5 % ... 95 % |
| Standards/specifications | IEC 61643-11 |
| Note | 2011 |
| Standards/specifications | EN 61643-11 |
| Note | 2012 |
| Standards/specifications | EN 61643-21 |
| Note | A2:2013 |
| Standards/specifications | IEC 61643-21 |
| Note | A2:2012 |
| Mounting type | Plugging into the mains socket |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.
5/5 .
— CHE 5/6/26, 10:33 AM
Product:MTZ18-4VM DANFOSS REFRIGERATION Reciproc...
5/5 merci beaucoup
— sotitradim 11/29/25, 11:12 AM
Product:SL20,MNM,IP42,300lm,1H SL2MNM42H1C EATON...
4/5 a,azing to use it
— B rahul 10/4/25, 8:05 AM
Product:661601 LEGRAND URA21LED 70LM 1H IP42 NP
4/5 Amazing to use it
— B rahul 10/4/25, 8:04 AM
Product:661601 LEGRAND URA21LED 70LM 1H IP42 NP