Primary switching power supplies, QUINT POWER, Push-in connection, Rail mounting, input:1phase, output: 24 VDC / 3.8 A

Categories:

  • Low-voltage industrial components > DC-power supply
  • PHOENIX CONTACT > Power Supplies (PS)

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX CONTACT

  • More Info
  • ETIM
  • Reviews
Guarantee, repair and return.

Unit Price: 158,73 €

This price is per unit and is the net value (not including taxes if applicable).

Calculate price by quantity

QuantityPrice

Standard lead time: 2-3 weeks.

  • These delivery times are an estimate any may vary when the item order has been processed.

LAST VIEWED

MORE INFO

Key Commercial Data

Orderkey2909577
Packing unit1 pc
GTIN4055626356488
Weight per Piece (excluding packing)380.000 g
Custom tariff number85044030
Country of originDE (Germany)

Dimensions

Width45 mm
Height106 mm
Depth90 mm

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)-25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
Ambient temperature (start-up type tested)-40 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Climatic class3K3 (in acc. with EN 60721)
Degree of pollution2
Installation height≤ 5000 m (> 2000 m, observe derating)

Input data

Input voltage range100 V AC ... 240 V AC -15 % ... +10 %
110 V DC ... 250 V DC -20 % ... +40 %
Dielectric strength maximum300 V AC 30 s
Discharge current to PE< 0.25 mA (264 V AC, 60 Hz)
Current consumption1 A (100 V AC)
0.83 A (120 V AC)
0.46 A (230 V AC)
0.44 A (240 V AC)
Nominal power consumption104 VA
Inrush surge currenttyp. 13 A (at 25 °C)
Mains bufferingtyp. 35 ms (120 V AC)
typ. 35 ms (230 V AC)
Input fuse3.15 A (slow-blow, internal)
Choice of suitable circuit breakers6 A ... 16 A (Characteristic B, C, D, K or comparable)
Type of protectionTransient surge protection
Protective circuit/componentVaristor

Output data

Nominal output voltage24 V DC
Setting range of the output voltage (USet)24 V DC ... 28 V DC (constant capacity)
Nominal output current (IN)3.8 A
Dynamic Boost (IDyn.Boost)7 A (≤ 60 °C (5 s))
Derating> 60 °C (2.5%/K)
Connection in parallelYes, for redundancy and increased capacity
Connection in seriesyes
Feedback resistance≤ 35 V DC
Protection against surge voltage on the output≤ 32 V DC
Control deviation< 0.5 % (Static load change 10 % ... 90 %)
< 3 % (Dynamic load change 10 % ... 90 %, (10 Hz))
< 0.2 % (change in input voltage ±10 %)
Residual ripple< 45 mVPP(with nominal values)
Output power90 W
Typical response time500 ms
Maximum power dissipation in no-load condition< 1 W (120 V AC)
< 1 W (230 V AC)
Power loss nominal load max.< 7 W (120 V AC)
< 6 W (230 V AC)

General

Net weight0.296 kg
Efficiencytyp. 92.8 % (120 V AC)
typ. 93.7 % (230 V AC)
Insulation voltage input/output4 kV AC (type test)
3 kV AC (routine test)
Protection classII
Degree of protectionIP20
MTBF (IEC 61709, SN 29500)> 1272000 h (25 °C)
> 690000 h (40 °C)
> 271000 h (60 °C)
Assembly instructionsDIN rail mounting

Connection data, input

Connection methodPush-in technology
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Stripping length10 mm

Connection data, output

Connection methodPush-in technology
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Stripping length10 mm

Connection data for signaling

Connection methodPush-in technology
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Stripping length10 mm

Standards and Regulations

Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Standards/regulationsEN 61000-4-2
Contact discharge4 kV (Test Level 2)
Standards/regulationsEN 61000-4-3
Frequency range80 MHz ... 1 GHz
Test field strength10 V/m (Test Level 3)
Frequency range1.4 GHz ... 2 GHz
Test field strength3 V/m (Test Level 2)
Standards/regulationsEN 61000-4-4
CommentsCriterion B
Standards/regulationsEN 61000-4-6
Frequency range0.15 MHz ... 80 MHz
Voltage10 V (Test Level 3)
Conducted noise emissionEN 55016 EN 61000-6-4 (Class A)
Standards/regulationsEN 61000-4-8
EN 61000-4-11
EN 61000-4-9
EN 61000-4-12
EN 61000-4-16
EN 61000-4-18
Standard - Safety of transformersEN 61558-2-16
Standard - Electrical safetyIEC 61010-2-201 (SELV)
Standard - power supply devices for low voltage with DC outputEN 61204-3
Standard – Safety extra-low voltageIEC 61010-1 (SELV)
IEC 61010-2-201 (PELV)
Standard - Safe isolationIEC 61558-2-16
IEC 61010-2-201
Standard – Limitation of mains harmonic currentsEN 61000-3-2
UL approvalsUL Listed UL 61010-1
UL Listed UL 61010-2-201
UL 1310 Class 2 Power Units
ANSI/UL 121201 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
Shock18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation)< 15 Hz, ±2.5 mm amplitude; 15 Hz ... 100 Hz: 2.3 g 90 Min. (in accordance with IEC 60068-2-6)
Overvoltage category (EN 61010-1)II
Overvoltage category (EN 62477-1)III (≤ 2000 m)

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 25;
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

ETIM for 2909577 Low-voltage industrial controls and switchgear (EC002540)

Feature nameVoltage type (supply voltage) (EF002991)
Feature valueAC/DC
Feature name1st secondary output voltage (EF006792)
Feature value24 V
Feature nameMax. output current 1 (EF008284)
Feature value7 A
Feature nameSecondary voltage adjustable (EF007002)
Feature valueYes
Feature nameNominal value output voltage 1 (EF009393)
Feature value24 V
Feature nameNominal value output current 1 (EF009396)
Feature value3.8 A
Feature nameShort-circuit-proof (EF007332)
Feature valueYes
Feature nameRated supply voltage AC 50 Hz (EF007076)
Feature value100 V
Feature nameRated supply voltage AC 60 Hz (EF007077)
Feature value100 V
Feature nameRated supply voltage DC (EF007078)
Feature value110 V
Feature nameOutput voltage stabilized (EF003092)
Feature valueYes
Feature namePower consumption (EF000346)
Feature value104 VA
Feature namePower output (EF003034)
Feature value90 W
Feature nameStabilized (EF005302)
Feature valueYes
Feature nameType of electric connection (EF003961)
Feature valueOther
Feature nameSuitable for rail mounting (EF003972)
Feature valueYes
Feature nameWall mounting possible (EF003973)
Feature valueNo
Feature nameModular version (EF001126)
Feature valueNo
Feature nameBuilt-in height (EF000332)
Feature value106 mm
Feature nameDirect mounting possible (EF005689)
Feature valueNo
Feature nameWidth (EF000008)
Feature value45 mm
Feature nameHeight (EF000040)
Feature value106 mm
Feature nameDepth (EF000049)
Feature value90 mm
Feature nameSuitable for safety functions (EF001597)
Feature valueYes
Feature nameSIL according to IEC 61508 (EF009889)
Feature valueNone
Feature namePerformance level according to EN ISO 13849-1 (EF007399)
Feature valueNone
Feature nameDegree of protection (IP) (EF005474)
Feature valueIP20
Feature nameDegree of protection (NEMA) (EF011959)
Feature valueOther

DATASHEET - PDF

Title
Size
Type

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.