PHOENIX CONTACT  SACC-E-M12MS-5CON-PG 9/0,5 VA 1554568 - Image 1

Images are for illustrative purposes only. Please refer to data sheet for details.

SACC-E-M12MS-5CON-PG 9/0,5 VA 1554568 PHOENIX CONTACT Panel feed-through

Reference: SACC-E-M12MS-5CON-PG 9/0,5 VA

Code: 1554568

Manufacturer: PHOENIX CONTACT

Description:

Panel feed-through
Conect. plug. to be apar. front wall, Universal, 5-pole, Male connector, straight, M12-Standard, encoding: A, to free cable end, Front mounting, Pg9, Single stranded wires, cable length: 0.5 m, 0.34 mm², TPE braided wire
Device connector front mounting, Universal, 5-position, Pin, straight, M12-Standard, coding: A, on free cable end, Front mounting, Pg9, Individual wires, cable length: 0.5 m, 0.34 mm2, TPE litz wire

Categories:

  • Connectors > Circular connector, mounting (with cable)
  • PHOENIX CONTACT > Field Device Connectors (FDC)

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX CONTACT

  • More Info
  • ETIM
  • PDF
  • Reviews
Guarantee, repair and return.

Unit Price: 32,68 €

This price is per unit and is the net value (not including taxes if applicable).

Calculate price by quantity

QuantityPrice

Standard lead time: 2-3 weeks.

  • These delivery times are an estimate any may vary when the item order has been processed.

MORE INFO

Technical data

Notes
Notes on operationThe electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration.
GeneralContact connection method: Crimp connection
Safety note
Safety noteWARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property.
• WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible.
• WARNING: Only electrically qualified personnel may install and operate the product. They must observe the following safety notes. The qualified personnel must be familiar with the basics of electrical engineering. They must be able to recognize and prevent danger. The relevant symbol on the packaging indicates that only personnel familiar with electrical engineering are allowed to install and operate the product.
• The products are suitable for applications in plant, controller, and electrical device engineering.
• When operating the connectors in outdoor applications, they must be separately protected against environmental influences.
• Assembled products may not be manipulated or improperly opened.
• Only use mating connectors that are specified in the technical data of the standards listed (e.g. the ones listed in the product accessories online at phoenixcontact.com/products).
• When using the product in direct connection with third-party manufacturers, the user is responsible.
• For operating voltages > 50 V AC, conductive connector housings must be grounded
• Ensure that when laying the cable, the tensile load on the connectors does not exceed the upper limit specified in the standards.
• Observe the corresponding technical data. You will find information:
o On the product
o On the packing label
o In the supplied documentation
o Online at phoenixcontact.com/products under the product
• Only use tools recommended by Phoenix Contact
• Use a protective cap to protect connectors that are not in use. The suitable accessories are available online in the accessory section of the product at phoenixcontact.com/products
• Ensure that the protective or functional ground has been properly connected.
• VDE 0100/1.97 § 411.1.3.2 and DIN EN 60 204/11.98 § 14.1.3 are applicable when combining several circuits in a cable and/or connector
• The connector warms up in normal operation. Depending on the ambient conditions, the surface of the connector can continue to warm up. In this case, the user is responsible for posting warnings (e.g. DIN EN ISO 13732-1:2008-12).

Mounting
Mounting typeFront mounting Pg9

Product properties
Product typeCircular connectors (device side)
ApplicationSignal
Sensor typeUniversal
Number of positions5
No. of cable outlets1
Shieldedno
CodingA
Thread typeM12
Data management status
Article revision11
Insulation characteristics
Overvoltage categoryII
Degree of pollution3

Material specifications
Flammability rating according to UL 94V0
Seal materialFKM
Contact materialCu alloy
Contact surface materialAu
Contact carrier materialPA 66 GF
Material for screw connectionStainless steel
Conductor materialTin-plated Cu litz wires

Electrical properties
Rated surge voltage1.5 kV
Contact resistance≤ 3 mΩ
Insulation resistance> 100 MΩ
Nominal voltage UN60 V (AC)
60 V (DC)
Nominal current IN4 A
Max. conductor resistance57.6 Ω/km

Connection data
Conductor connection
Connection methodIndividual wires
Contact connection typePin
Conductor cross section0.34 mm²
Tightening torque2 Nm ... 3 Nm (Installation-side)

Mechanical properties
Mechanical data
Insertion/withdrawal cycles> 100

Connector
Connection 1
Head designPin
Head cable outletstraight
Head thread typeM12
Head locking typeStandard
CodingA
Connection 2
Head designfree cable end

Cable/line
Cable length0.5 m
Cable typeTPE litz wire
Signal type/categoryUniversal
Wire diameter incl. insulation1.2 mm ±0.07 mm
Single wire, colorblack, brown,blue, white, gray
Cable cross section0.34 mm²
Conductor materialTin-plated Cu litz wires
Conductor structure signal line7x 0.25 mm
AWG signal line22
Material wire insulationTPE
Thickness, insulation0.21 mm
Nominal voltage, cable300 V
Test voltage, cable2000 V AC
Cable resistance≤ 57.6 Ω/km
Cable insulation resistance≥ 20 MΩ*km
Ambient temperature (operation)-40 °C ... 85 °C (cable, fixed installation)
-25 °C ... 85 °C (Cable, flexible installation)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP65/IP67/IP69/IP69K
IP65/IP67/IP69K
Ambient temperature (operation)-25 °C ... 85 °C (Plug / socket)
-40 °C ... 85 °C (without mechanical actuation)
-25 °C ... 85 °C (Cable, flexible installation)
-40 °C ... 85 °C (cable, fixed installation)

Standards and regulations
M12
Standard designationM12 connector
Standards/specificationsIEC 61076-2-101

ETIM for 1554568 Connectors (EC003570)

Feature nameCable length (EF000536)
Feature value0.5 mm
Feature nameType of plug-in contact, outer side (EF005528)
Feature valueNone
Feature nameMounting method (EF000003)
Feature valueFront mounting
Feature nameHousing material (EF001596)
Feature valueOther
Feature nameMaterial core insulation (EF000061)
Feature valueOther
Feature nameMaterial of contact surface (EF004020)
Feature valueOther
Feature nameInflammability class of insulation material according to UL94 (EF002521)
Feature valueV0
Feature nameAmbient temperature (EF002386)
Feature value85 °C
Feature nameOperating temperature (EF002393)
Feature value-25 °C
Feature nameRated voltage (EF000228)
Feature value60 V
Feature nameWith shield connection (EF002535)
Feature valueNo
Feature nameScrew-in thread (EF012303)
Feature valueM12
Feature nameCore cross section (EF000018)
Feature value0.34 mm²
Feature nameMin. number of insertion cycles (EF012212)
Feature value100
Feature nameDegree of protection (IP), mounted (EF007466)
Feature valueIP69K

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.