NBC-MSX/0,35-94S SCO RAIL 1580186 PHOENIX CONTACT Network cable, CAT6A Ethernet (10 GBit/s), 8-pole, M12 SPE..

Reference: NBC-MSX/0,35-94S SCO RAIL

Code: 1580186

Manufacturer: PHOENIX CONTACT

Product on demand only, returns will not be accepted.

Description:

Network cable, CAT6A Ethernet (10 GBit/s), 8-pole, M12 SPEEDCON straight connector, encoding: X, to free cable end, cable length: 0.35 m, For railway applications
Network cable
Network cable, Ethernet CAT6A (10 Gbps), 8-position, Plug straight M12 SPEEDCON, coding: X, on free cable end, cable length: 0.35 m, For railway applications

Categories:

  • Sensors > Sensor-actuator patch cord
  • PHOENIX CONTACT > Industrial Field Connectivity (IFC)

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX CONTACT

  • More Info
  • ETIM
  • Reviews
Guarantee, repair and return.

Total: 3.277,09 €

Unit Price: 32,7709 €

This price is per unit and is the net value (not including taxes if applicable).

Calculate price by quantity

QuantityPrice

Standard lead time: 4-5 weeks.

  • These delivery times are an estimate any may vary when the item order has been processed.

LAST VIEWED

MORE INFO

Technical data

Product properties
Product typeData cable preassembled
Sensor typeEthernet
Number of positions8
ApplicationNetwork
No. of cable outlets1
Shieldedyes
CodingX

Interfaces
Bus systemEthernet
Signal type/categoryEthernet CAT6A, 10 Gbps

Signaling
Status displayNo
Status display presentNo

Electrical properties
Nominal voltage UN48 V AC
60 V DC
Nominal current IN0.5 A
Transmission mediumCopper
Transmission characteristics (category)CAT6A

Connector
Connection 1
TypePlug straight M12 SPEEDCON
Locking typeSPEEDCON
Coding typeX (Data)
MaterialCuZn (Contact)
Ni/Au (Contact surface)
PP (Contact carriers)
TPU, hardly inflammable, self-extinguishing (Grip)
Zinc die-cast, nickel-plated (Screw connection)
Connection 2
Typefree cable end

Cable/line
Cable length0.35 m
Ethernet BETAtrans®railway application CAT7 [94S]
Dimensional drawingtchxdwnovi.jpg
Shieldedyes
Cable weight59 kg/km
Copper weight28 kg/km
Cable typeEthernet BETAtrans®railway application CAT7
Cable type (abbreviation)94S
Signal type/categoryEthernet CAT7, 10 Gbps
Cable structure4x2xAWG26/7; S/FTP
External cable diameter6.6 mm ±0.2 mm
Outer sheath, materialPE-X
External sheath, colorblack
Conductor materialTin-plated Cu litz wires
Conductor structure signal line7x 0.16 mm
AWG signal line26
Conductor cross section4x 2x 0.14 mm²
Material wire insulationCell PE
Wire diameter incl. insulation1.05 mm ±0.1 mm
Single wire, colorwhite-blue, white-orange, white-green, white-brown
Twisted pairs2 cores to the pair
Type of pair shieldingAluminum-lined polyester foil
Overall twist4 pairs, twisted
ShieldingTinned copper braided shield
Nominal voltage, cable125 V AC (Uo)
Test voltage Core/Core1000 V AC (50 Hz, 1 min.)
Test voltage Core/Shield1000 V AC (50 Hz, 1 min.)
Cable resistance≤ 145 Ω/km
Cable insulation resistance≥ 5 GΩ*km
Coupling resistance5.00 mΩ/m (at 10 MHz)
Wave impedance100 Ω ±5 Ω (at 100 MHz)
Working capacitance44 nF (per kilometer)
Signal runtime4.4 ns/m
Signal speed0.78 c
Interference suppression90 dB (up to 1000 MHz)
Tensile strength≤ 60 N (temporary)
≤ 15 N (Permanent)
Minimum bending radius, fixed installation6 x D
Damping0.25 dB (with 1 MHz)
0.76 dB (at 10 MHz)
2.49 dB (at 100 MHz)
3.69 dB (at 200 MHz)
4.18 dB (at 250 MHz)
5.6 dB (at 500 MHz)
6.74 dB (at 600 MHz)
7.32 dB (at 700 MHz)
7.89 dB (at 800 MHz)
8.5 dB (at 900 MHz)
9.11 dB (at 1000 MHz)
9.5 dB (at 1100 MHz)
9.9 dB (at 1200 MHz)
Near end crosstalk attenuation (NEXT)100 dB (with 1 MHz)
99 dB (at 10 MHz)
95 dB (at 100 MHz)
92 dB (at 200 MHz)
90 dB (at 250 MHz)
83 dB (at 500 MHz)
81 dB (at 600 MHz)
80 dB (at 700 MHz)
77 dB (at 800 MHz)
75 dB (at 900 MHz)
74 dB (at 1000 MHz)
72 dB (at 1100 MHz)
70 dB (at 1200 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)97 dB (with 1 MHz)
96 dB (at 10 MHz)
92 dB (at 100 MHz)
89 dB (at 200 MHz)
87 dB (at 250 MHz)
80 dB (at 500 MHz)
78 dB (at 600 MHz)
77 dB (at 700 MHz)
74 dB (at 800 MHz)
72 dB (at 900 MHz)
71 dB (at 1000 MHz)
69 dB (at 1100 MHz)
67 dB (at 1200 MHz)
Return attenuation (RL)24 dB (with 1 MHz)
33.9 dB (at 10 MHz)
38.3 dB (at 100 MHz)
35.3 dB (at 200 MHz)
32.9 dB (at 250 MHz)
29.7 dB (at 500 MHz)
30.6 dB (at 600 MHz)
31 dB (at 700 MHz)
26.7 dB (at 800 MHz)
28.6 dB (at 900 MHz)
27.5 dB (at 1000 MHz)
26.9 dB (at 1100 MHz)
26.3 dB (at 1200 MHz)
Shield attenuation60 dB (up to 1000 MHz)
Crosstalk attenuation (ACR)100 dB (with 1 MHz)
99 dB (at 10 MHz)
93 dB (at 100 MHz)
88 dB (at 200 MHz)
86 dB (at 250 MHz)
78 dB (at 500 MHz)
74 dB (at 600 MHz)
72 dB (at 700 MHz)
69 dB (at 800 MHz)
67 dB (at 900 MHz)
65 dB (at 1000 MHz)
63 dB (at 1100 MHz)
61 dB (at 1200 MHz)
Power-summated crosstalk attenuation (PS-ACR)97 dB (with 1 MHz)
96 dB (at 10 MHz)
90 dB (at 100 MHz)
85 dB (at 200 MHz)
83 dB (at 250 MHz)
75 dB (at 500 MHz)
71 dB (at 600 MHz)
69 dB (at 700 MHz)
66 dB (at 800 MHz)
64 dB (at 900 MHz)
62 dB (at 1000 MHz)
60 dB (at 1100 MHz)
58 dB (at 1200 MHz)
Fire protection in rail vehiclesBS 6853 (Internal cable Ia, Ib, II/external cable Ia, Ib, II)
DIN 5510-2 (Fire protection level 1, 2, 3, 4)
EN 45545-2
EN 50306-4
NF F16-101 (Classification C/F1)
NF F16-101 (Internal cable A1, A2, B/external cable A1, A2, B)
NFPA 130
PN-K-02511 (Class A)
UIC 564-2 (Class A)
Halogen-freein accordance with EN 50267-2-1
in accordance with EN 60684-2
Resistance to oilin accordance with EN 50306-4, 72 hours at 100°C, IRM 902
Concentration of fumesEN 61034-2
Flame resistancein accordance with EN 60332-1-2
EN 60332-3-25
in accordance with ISO 14572 5.21 (UN ECE-R 118.01)
Other resistanceResistant to fuel in accordance with EN 50306-4, 168 hours at 70°C, IRM 903
Resistant to ozone in accordance with EN 50306-4, 72 hours at 40°C, method B, volumetric concentration of 200 x 10-6
Special propertiesHL1-HL3
Ambient temperature (operation)-40 °C ... 80 °C (cable, fixed installation)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP65
IP67
Ambient temperature (operation)-25 °C ... 90 °C (M12 connector)

Standards and regulations
M12
Standard designationM12 connector

ETIM for 1580186 Sensors (EC001855)

Feature nameNumber of poles (EF001391)
Feature value8
Feature nameType of electrical connection, field-sided (EF005525)
Feature valueOther
Feature namePositioning cable feed, field-sided (EF005928)
Feature valueOther
Feature nameType of electrical connection, box-sided (EF005524)
Feature valueM12
Feature nameType of plug-in contact, box-sided (EF008386)
Feature valueMale (plug)
Feature namePositioning cable feed, box-sided (EF005927)
Feature valueStraight
Feature nameCable length (EF000536)
Feature value0.35 m
Feature nameMaterial of cable sheath (EF004136)
Feature valueOther
Feature nameHalogen free (EF000025)
Feature valueYes
Feature nameColour cable sheath (EF008249)
Feature valueBlack
Feature nameWith LED indication (EF005950)
Feature valueNo
Feature nameScreened (EF000881)
Feature valueYes
Feature nameVulcanize (EF004115)
Feature valueNo
Feature nameMaterial contact body (EF008248)
Feature valueOther
Feature namePermitted cable outer temperature after assembling without vibration (EF001686)
Feature value-40 °C
Feature nameRated current In (EF008250)
Feature value0.5 A
Feature nameRated voltage (EF000228)
Feature value48 V
Feature nameDegree of protection (IP) (EF005474)
Feature valueIP65

DATASHEET - PDF

Title
Size
Type

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.