PHOENIX CONTACT  NBC-100,0-94S 1423514 - Image 1

Images are for illustrative purposes only. Please refer to data sheet for details.

NBC-100,0-94S 1423514 PHOENIX CONTACT Network cable

Reference: NBC-100,0-94S

Code: 1423514

Manufacturer: PHOENIX CONTACT

Product on demand only, returns will not be accepted.

Description:

Network cable
Network cable, CAT7 Ethernet (10 GBit/s), 8-pole, cable length: 100 m, For railway applications

Categories:

  • Cables > Data and communication cable
  • PHOENIX CONTACT > Industrial Field Connectivity (IFC)

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX CONTACT

  • More Info
  • ETIM
  • Reviews
Guarantee, repair and return.

Unit Price: 1.623,11 €

This price is per unit and is the net value (not including taxes if applicable).

Calculate price by quantity

QuantityPrice

Standard lead time: 4-5 weeks.

  • These delivery times are an estimate any may vary when the item order has been processed.

LAST VIEWED

MORE INFO

Key Commercial Data

Orderkey1423514
Packing unit1 pc
NoteMade to Order (non-returnable)
GTIN4055626346007
Weight per Piece (excluding packing)5,773.000 g
Custom tariff number85444995
Country of originDE (Germany)

Dimensions

Length of cable100 m

General data

Rated voltage30 V AC
30 V DC
Number of positions8
Signal type/categoryEthernet CAT7, 10 Gbps

Cable

Cable typeEthernet for rail applications
Cable type (abbreviation)94S
Signal type/categoryEthernet CAT7, 10 Gbps
Cable structure4x2xAWG26/7; S/FTP
Conductor cross section4x 2x 0.14 mm²
AWG signal line26
Conductor structure signal line7x 0.16 mm
Core diameter including insulation1.05 mm ±0.1 mm
Wire colorsWhite-blue, white-orange, white-green, white-brown
Twisted pairs2 cores to the pair
Type of pair shieldingAluminum-lined polyester foil
Overall twist4 pairs, twisted
ShieldingTinned copper braided shield
External sheath, colorblack
External cable diameter D6.6 mm ±0.2 mm
Minimum bending radius, fixed installation6 x D
Tensile strength GRP≤ 60 N (temporary)
≤ 15 N (Permanent)
Cable weight59 kg/km
Copper weight28 kg/km
Outer sheath, materialPE-X
Material conductor insulationCell PE
Conductor materialTin-plated Cu litz wires
Insulation resistance≥ 5 GΩ*km
Conductor resistance≤ 145 Ω/km
Working capacitance44 nF (per kilometer)
Wave impedance100 Ω ±5 Ω (at 100 MHz)
Near end crosstalk attenuation (NEXT)100 dB (with 1 MHz)
99 dB (at 10 MHz)
95 dB (at 100 MHz)
92 dB (at 200 MHz)
90 dB (at 250 MHz)
83 dB (at 500 MHz)
81 dB (at 600 MHz)
80 dB (at 700 MHz)
77 dB (at 800 MHz)
75 dB (at 900 MHz)
74 dB (at 1000 MHz)
72 dB (at 1100 MHz)
70 dB (at 1200 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)97 dB (with 1 MHz)
96 dB (at 10 MHz)
92 dB (at 100 MHz)
89 dB (at 200 MHz)
87 dB (at 250 MHz)
80 dB (at 500 MHz)
78 dB (at 600 MHz)
77 dB (at 700 MHz)
74 dB (at 800 MHz)
72 dB (at 900 MHz)
71 dB (at 1000 MHz)
69 dB (at 1100 MHz)
67 dB (at 1200 MHz)
Attenuation0.25 dB (with 1 MHz)
0.76 dB (at 10 MHz)
2.49 dB (at 100 MHz)
3.69 dB (at 200 MHz)
4.18 dB (at 250 MHz)
5.6 dB (at 500 MHz)
6.74 dB (at 600 MHz)
7.32 dB (at 700 MHz)
7.89 dB (at 800 MHz)
8.5 dB (at 900 MHz)
9.11 dB (at 1000 MHz)
9.5 dB (at 1100 MHz)
9.9 dB (at 1200 MHz)
Return loss (RL)24 dB (with 1 MHz)
33.9 dB (at 10 MHz)
38.3 dB (at 100 MHz)
35.3 dB (at 200 MHz)
32.9 dB (at 250 MHz)
29.7 dB (at 500 MHz)
30.6 dB (at 600 MHz)
31 dB (at 700 MHz)
26.7 dB (at 800 MHz)
28.6 dB (at 900 MHz)
27.5 dB (at 1000 MHz)
26.9 dB (at 1100 MHz)
26.3 dB (at 1200 MHz)
Crosstalk attenuation (ACR)100 dB (with 1 MHz)
99 dB (at 10 MHz)
93 dB (at 100 MHz)
88 dB (at 200 MHz)
86 dB (at 250 MHz)
78 dB (at 500 MHz)
74 dB (at 600 MHz)
72 dB (at 700 MHz)
69 dB (at 800 MHz)
67 dB (at 900 MHz)
65 dB (at 1000 MHz)
63 dB (at 1100 MHz)
61 dB (at 1200 MHz)
Power-summated crosstalk attenuation (PS-ACR)97 dB (with 1 MHz)
96 dB (at 10 MHz)
90 dB (at 100 MHz)
85 dB (at 200 MHz)
83 dB (at 250 MHz)
75 dB (at 500 MHz)
71 dB (at 600 MHz)
69 dB (at 700 MHz)
66 dB (at 800 MHz)
64 dB (at 900 MHz)
62 dB (at 1000 MHz)
60 dB (at 1100 MHz)
58 dB (at 1200 MHz)
Signal speed0.78 c
Signal runtime4.4 ns/m
Shield attenuation60 dB (up to 1000 MHz)
Interference suppression90 dB (up to 1000 MHz)
Coupling resistance5.00 mΩ/m (at 10 MHz)
Nominal voltage, cable125 V AC (Uo)
Test voltage Core/Core1000 V AC (50 Hz, 1 min.)
Test voltage Core/Shield1000 V AC (50 Hz, 1 min.)
Fire protection in rail vehiclesBS 6853 (Internal cable Ia, Ib, II/external cable Ia, Ib, II)
DIN 5510-2 (Fire protection level 1, 2, 3, 4)
EN 45545-2
EN 50306-4
NF F16-101 (Classification C/F1)
NF F16-101 (Internal cable A1, A2, B/external cable A1, A2, B)
NFPA 130
PN-K-02511 (Class A)
UIC 564-2 (Class A)
Flame resistanceaccording to EN 60332-1-2
EN 60332-3-25
according to ISO 14572 5.21 (UN ECE-R 118.01)
Halogen-freeAccording to EN 50267-2-1
according to EN 60684-2
Resistance to oilaccording to EN 60684-2, 72 h at 100 °C, IRM 902
Other resistanceResistant to fuel according to EN 60684-2, 72 h at 100 °C, IRM 903
Resistant to ozone according to EN 50306-4, 72 h at 40 °C, procedure B, volume concentration 200 x 10-6
Concentration of fumesEN 61034-2
Ambient temperature (operation)-40 °C ... 80 °C (cable, fixed installation)

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

ETIM for 1423514 Cable (EC003249)

Feature nameConductor surface (EF010804)
Feature valueOther
Feature nameDiameter conductor (EF001621)
Feature value1.05 mm
Feature nameNominal cross section conductor (EF000060)
Feature value0.14 mm²
Feature nameConductor category (EF001632)
Feature valueClass 2 = stranded
Feature nameNumber of cores (EF001792)
Feature value8
Feature nameMaterial core insulation (EF000061)
Feature valueOther
Feature nameSpecification core insulation (EF011805)
Feature valuePolyethylene (PE)
Feature nameCore identification (EF000067)
Feature valueOther
Feature nameScreen over stranding element (EF001623)
Feature valueBraiding
Feature nameStranding (EF003802)
Feature valueOther
Feature nameLongitudinal water blocking cable (EF011011)
Feature valueNo
Feature nameRadial water blocking cable (EF011012)
Feature valueNo
Feature nameSuitable for underground installation (EF003689)
Feature valueNo
Feature nameProtective sheath (EF001691)
Feature valueNone
Feature nameMaterial outer sheath (EF001625)
Feature valueOther
Feature nameSpecification material outer sheath (EF011806)
Feature valueOther
Feature nameColour outer sheath (EF001618)
Feature valueBlack
Feature nameLow smoke according to EN IEC 61034-2 (EF003799)
Feature valueNo
Feature nameOil resistant according to EN IEC 60811-404 (EF009770)
Feature valueNo
Feature nameOuter diameter approx. (EF003921)
Feature value6.6 mm
Feature nameMin. permitted bending radius, stationary application/permanent installation (EF011803)
Feature value40 mm
Feature namePermitted cable outer temperature after assembling without vibration (EF001686)
Feature value-40 °C
Feature nameCategory (EF001619)
Feature valueOther

DATASHEET - PDF

Title
Size
Type

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.