Product successfully added to your shopping cart
MACX MCR-EX-TS-I-OLP-SP
2908661
PHOENIX_CONTACT
1
The output-loop-powered temperature transmitter transmits up to two sensor signals from RTD and TC sensors as well as from resistance-type sensors and voltage sensors via HART communication or 4 ... 20 mA, configurable. SIL 2/3, intrinsic safety, Push-in connection.
Ex i, Output Loop-Fed Temperature Converter to transmit up to 2 sensor signals from RTD and CT sensors, as well as resistance and voltage transmitters using 4 mA... 20 mA. HART, Standard Configuration, Safety Integrity Level (SIL, IEC61508): 2, Systematic Capability: 3, Push-in Connection
Sensors > Temperature transformer
INTERFACE Components (IF)
Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Orderkey | 2908661 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 190 (C-5-2019) |
| GTIN | 4055626355436 |
| Weight per Piece (excluding packing) | 0.000 g |
| Custom tariff number | 85437090 |
| Country of origin | DE (Germany) |
| Ambient temperature (operation) | -40 °C ... 85 °C |
|---|---|
| -40 °C ... 70 °C (SIL active) | |
| Ambient temperature (storage/transport) | -40 °C ... 100 °C |
| Maximum altitude | ≤ 4000 m (Above sea level) |
| Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
| Degree of protection | IP20 (not assessed by UL) |
| Connection method | Push-in connection |
|---|---|
| Stripping length | 8 mm |
| Conductor cross section solid | 0.2 mm² ... 1.5 mm² |
| Conductor cross section flexible | 0.2 mm² ... 1.5 mm² |
| Conductor cross section AWG | 24 ... 16 |
| Step response (0–99%) | 0.8 s (TC) |
|---|---|
| Degree of pollution | 2 |
| Overvoltage category | II |
| Color | gray |
| Conformance | CE-compliant |
| ATEX | II 2 (1) G Ex ib [ia Ga] IIC T6...T4 Gb |
| IECEx | Ex ib [ia Ga] IIC T6...T4 Gb |
| UL, USA/Canada | UL 61010 Recognized |
| FM approval | Exia / Class I / Div. 1, 2 / Group ABCD |
| CSA | AIS / Class I / Div. 1 / ABCD |
| Conformance | CE-compliant |
|---|---|
| ATEX | II 2 (1) G Ex ib [ia Ga] IIC T6...T4 Gb |
| IECEx | Ex ib [ia Ga] IIC T6...T4 Gb |
| UL, USA/Canada | UL 61010 Recognized |
| FM approval | Exia / Class I / Div. 1, 2 / Group ABCD |
| NI, Class I, Div. 2, Groups A, B, C, D | |
| CSA | AIS / Class I / Div. 1 / ABCD |
| NI / Class I / Div. 2 / ABCD T6/T5/T4 |
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
|---|---|
| No hazardous substances above threshold values |
| Feature Name | Feature Value |
|---|---|
| Measuring range (EF001836) | -250 °C |
| Analogue output 0 mA ... 20 mA (EF006808) | No |
| Analogue output 4 mA ... 20 mA (EF006810) | Yes |
| Analogue output 0 V ... 2 V (EF009886) | No |
| Analogue output 0 V ... 5 V (EF009887) | No |
| Analogue output 0 V ... 10 V (EF006807) | No |
| Analogue output 2 V ... 10 V (EF009888) | No |
| With switching output (EF005225) | No |
| Modular version (EF001126) | Yes |
| Integrated configuration function (EF003064) | No |
| Ambient temperature (EF002386) | 85 °C |
| Weight (EF000167) | 0.2057 kg |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG PHOENIX INTERFACE TECHNOLOGY AND SWITCHING DEVICES EN.pdf | 29 Mbytes |
|
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.