| Orderkey | 2862291 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 27 (AX-2009) |
| GTIN | 4017918909116 |
| Weight per Piece (excluding packing) | 366.300 g |
| Custom tariff number | 85371091 |
| Country of origin | DE (Germany) |
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
| Degree of protection | IP20 |
|---|---|
| Ambient temperature (operation) | -25 °C ... 55 °C |
| Ambient temperature (storage/transport) | -25 °C ... 75 °C |
| Permissible humidity (operation) | 5 % ... 85 % (non-condensing) |
| Permissible humidity (storage/transport) | 5 % ... 85 % (non-condensing) |
| Air pressure (operation) | 70 kPa ... 108 kPa (up to 3000 m above sea level) |
| Air pressure (storage/transport) | 66 kPa ... 108 kPa (up to 3500 m above sea level) |
| Shock | 25g, Criterion 1, according to IEC 60068-2-27 |
| Vibration (operation) | 2g, criterion 1 according to IEC 60068-2-6 |
| Interface | INTERBUS local bus (master) |
|---|---|
| Number | 1 |
| Connection method | Inline data jumper |
| Transmission speed | 500 kBaud / 2 MBaud (can be switched) |
| Interface | Higher-level INTERBUS local bus (slave) |
| Number | 1 |
| Connection method | Inline data jumper |
| Transmission speed | 500 kBaud |
| Interface | Parameterization/operation/diagnostics |
| Number | 1 |
| Connection method | 6-pos. MINI DIN socket (PS/2) |
| Transmission speed | 19200 Baud |
| Typical current consumption | 250 mA (no local bus device connected during idling, bus inactive) |
|---|---|
| Supply voltage | 7.5 V DC (the power supply comes from the upstream bus coupler) |
| Supply voltage range | 19.2 V DC ... 30 V DC |
| Residual ripple | ±5 % |
| Power dissipation | max. 1.875 W |
| Max. total permissible current consumption of all I/O terminal blocks | Communications power (7,5 V DC) the power supply comes from the upstream bus coupler |
| Analog supply (24 V DC) = 0.5 A |
| Amount of process data | max. 4096 Bit (INTERBUS-Master) |
|---|---|
| 192 Bit (INTERBUS-Slave) | |
| Number of parameter data | max. 8 Byte (configurable) |
| Number of supported devices | max. 512 |
| Number of local bus devices that can be connected | max. 63 (observe current consumption) |
| Number of devices with parameter channel | max. 62 |
| Number of supported branch terminals with remote bus branch | max. 15 |
| Input name | Digital inputs |
|---|---|
| Number of inputs | 4 |
| Connection method | Inline potential distributor |
| Connection technology | 2, 3, 4-wire |
| Description of the input | Interrupt input, fast counter, pulse generator |
| Output name | Digital outputs |
| Number of outputs | 2 |
| Connection method | Spring-cage connection |
| Connection technology | 2, 3, 4-wire |
| Maximum output current per channel | 500 mA |
| Number of pulse direction outputs | 2 |
| Limit frequency | 20 kHz |
| Number of inputs | 4 |
| Input frequency | 40 kHz |
| Engineering tool | PC WORX |
|---|---|
| Program memory | typ. 384 kByte (32 K instructions (IL)) |
| Mass storage | 330 kByte |
| Retentive mass storage | 8 kByte (NVRAM) |
| Number of control tasks | 8 |
| Realtime clock | Integrated (battery backup) |
| Vibration (storage/transport) | 2g, criterion 1 according to IEC 60068-2-6 |
|---|---|
| Connection in acc. with standard | CUL |
| Shock | 25g, Criterion 1, according to IEC 60068-2-27 |
| Vibration (operation) | 2g, criterion 1 according to IEC 60068-2-6 |
| REACh SVHC | 1,2-dimethoxyethane,ethylene glycol dimethyl ether (EGDME) 110-71-4 |
|---|---|
| China RoHS | Environmentally Friendly Use Period = 50 |
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.
5/5 .
— CHE 5/6/26, 10:33 AM
Product:MTZ18-4VM DANFOSS REFRIGERATION Reciproc...
5/5 merci beaucoup
— sotitradim 11/29/25, 11:12 AM
Product:SL20,MNM,IP42,300lm,1H SL2MNM42H1C EATON...
4/5 a,azing to use it
— B rahul 10/4/25, 8:05 AM
Product:661601 LEGRAND URA21LED 70LM 1H IP42 NP
4/5 Amazing to use it
— B rahul 10/4/25, 8:04 AM
Product:661601 LEGRAND URA21LED 70LM 1H IP42 NP